What a charge through 1 kΩ costs, against how long it is given
Drawn above at its default parameters, which is almost never how an essay calls it. A placement states the numbers that essay is arguing about, so the figure a reader meets is about that argument rather than about the generator — 98% of the placements on this site pass one, and the phase that raised that number from 12% found eight captions describing a figure the page was not showing.
At those defaults the edge it states is a tenth of the loss needs 20 ms — the right-hand slot
of the caption strip, which on this site is never used for anything else, and which is read
back out of the drawing above rather than out of the code that wrote it.
It belongs to Before the steady state, which is to say a change to it is a
change to lib/figures/transients.js.
It takes a slider on resistance (ohms) with 5 settings,
and every one of them has passed the same assertions as the frame above — a figure whose
circuit stops doing what its caption says at any setting stops the build.
Called by 8 essays
which is the blast radius of changing it
The half that never arrives
Charging a capacitor from a step loses exactly as much energy as it stores, and the resistance it is lost in does not appear in the answer — the same 12.5 microjoules through ten ohms and through a hundred kilohms, to nine figures. Drive the same network with a ramp instead and the loss falls as two time constants over the ramp, with no floor beneath it at all.
The first cycle, which no steady state contains
Every number this field computes about a rectifier — the ripple, the crest factor, the conduction angle, the power factor — is read from the settled state, and the march that produces them starts from an empty capacitor and throws the first cycle away. That first conduction carries 32.4 amperes against a repetitive peak of 1.23, it is 26 times larger than anything the circuit ever does again, and how large it is depends on when somebody's hand closed the switch.
The heat a recovery leaves behind
The essay below this one measured how much current a diode conducts backwards and for how long, and stopped there. Both numbers are multiplied by a voltage somewhere, and the surprise is where: while the junction is still conducting it holds almost nothing, so nine tenths of the energy is dissipated in the transistor pulling the current down and not in the diode. Repeat it a hundred thousand times a second and it is 1.5 watts, the lifetime rises with temperature, and above 1.28 megahertz the diode's own loop has no fixed point at all.
The inductance that limits, and lifts
Adding winding resistance to a rectifier limits the first peak and does not reduce the energy at all — the essay below measured ∫i²dt as two per cent apart over a factor of four in the resistance. Adding leakage inductance does both: it divides the peak by seven and the energy by five, and dissipates nothing to do it. What it buys instead is a rectifier whose output sits 29 per cent above the peak of its own supply, permanently, which every steady-state expression in this field says cannot happen.
The coefficient that is about one reading
A class II ceramic's temperature coefficient is a third printed number, and it is a coefficient of the one capacitance a data sheet reports: what a bridge sees at zero bias with a one-volt test. The model behind the part has two parameters, one number does not determine two, and every way of dividing a ±15 per cent envelope between them honours the envelope exactly while putting the working capacitance anywhere across twenty-nine points — and two parts a bridge cannot tell apart differ by 1.80 at the voltage they are used at.
Two loops, and one heatsink
The rung below this one found that nine tenths of a reverse recovery's energy is dissipated in the transistor and not in the diode, and then computed the diode's junction temperature with all of that energy in it. Repaired, the diode alone survives to 1.28 megahertz instead of 128 kilohertz — a factor of exactly the ninety per cent. What replaces the number is the arrangement that exists: two devices with two different positive temperature loops on one piece of aluminium, giving out at 135 kilohertz, and it is the switch that goes.
The pulse the heatsink does not feel
A thermal resistance iterated to a fixed point with a diode or a switch is a statement about a power — so it assumes that a hundred and fifty watts for two per cent of the time is three watts. The die's own heat capacity decides whether that is true, and it decides it at a frequency: above 308 hertz the junction integrates, by a hundred kilohertz the fixed point is exact to five parts in ten thousand, and at one hertz the same average power on the same heatsink puts the junction three hundred kelvin hotter.
The half a switch keeps
The rung below found that charging a capacitor from a step loses half the delivered energy whatever the resistance, and that a ramp takes the loss down as 2τ/T with no floor. A staircase of N settled risers costs one Nth of the step, exact to four parts in a million, and the law ends at a dwell of 5.272 time constants. A switch is the other half of the same product and buys nothing at all: with the supply held at five volts and the channel conductance ramped over a thousand time constants, the loss is 1.00000000 of ½CV².