The Steinmetz exponent is a local slope, and how far it moves is a property of the material
Drawn above at its default parameters, which is almost never how an essay calls it. A placement states the numbers that essay is arguing about, so the figure a reader meets is about that argument rather than about the generator — 98% of the placements on this site pass one, and the phase that raised that number from 12% found eight captions describing a figure the page was not showing.
At those defaults the edge it states is it moves by 1.42 here, 1.73 on a soft core — the right-hand slot
of the caption strip, which on this site is never used for anything else, and which is read
back out of the drawing above rather than out of the code that wrote it.
It belongs to Two windings, and the band between them, which is to say a change to it is a
change to lib/figures/magnetics.js.
It takes a slider on threshold spread, A/m with 5 settings,
and every one of them has passed the same assertions as the frame above — a figure whose
circuit stops doing what its caption says at any setting stops the build.
Called by 9 essays
which is the blast radius of changing it
The constant that is a window
A diode's ideality factor is quoted as a number and defined as a derivative, which means it has a value at every current and no value anywhere. Eight one-decade fits to one curve return factors from 1.23 to 1.98, two of them straight to a few parts in a thousand — so the residual gives no warning at all. Asked for the forward voltage at a milliamp, the window containing it is right to a third of a millivolt and the worst is out by 186, which is a current a hundredth of the truth.
The exponent nobody put in
A catalogue prints core loss as a coefficient times the frequency raised to one power and the flux to another, and the two exponents look like material constants. Neither is. On a loop built from play operators the frequency exponent is exactly one — a theorem, not a fit, because a rate-independent locus has the same area however fast it is traced — and the flux exponent is a local slope that runs from 2.94 at half a millitesla to 1.46 near saturation, so five windows on one measured curve give β from 1.58 to 2.84 and predictions three times apart at a hundred and fifty millitesla.
The duty cycle that costs nothing
A converter drives its core with a rectangular voltage, so the flux is a triangle whose two slopes differ by nineteen to one at a five per cent duty. The play-operator core charges exactly the same for all of them — 2.1006 joules per cubic metre at every duty and for a sinusoid of the same peak, to three parts in ten thousand — because a rate-independent locus depends on where the flux went and not on how fast. Real cores charge tens of per cent more, and the standard correction hides its entire waveform dependence in α − 1, which is the one term a rate-independent model has none of.
Two inductances at one current
A data sheet prints one L(i) curve and there are two. An operator sitting inside its own backlash contributes nothing to dB/dH, so a small excitation sees only the operators still moving — every one at the tip of a loop, none just after a reversal — and the same core at zero bias measures 14.90 millihenries pushed downward and 8.30 pushed upward, a factor of 1.80. The same split decides what a converter's ripple costs: held at the flux swing volt-seconds actually fix, a twenty-millitesla ripple costs twelve times more at a hundred and seventy-five amperes per metre of bias than at none, and above a hundred and eighty-three the question has no answer at all.
The current inside the iron
Every core-loss law has an eddy term of the form d²f²B²/6ρ, and it is derived by assuming the flux is uniform across the lamination — an assumption that is a frequency and that the expression does not carry. Solved instead as a diffusion, the exponent is exactly 2 below the frequency at which the sheet is two skin depths thick, exactly 1.5 above it, and it undershoots to 1.485 on the way. For a 0.35 mm sheet the crossing is 465 hertz, so at a kilohertz the classical term is 1.74 times the truth and at ten kilohertz it is forty-seven times.
The core the solver has to remember
A saturating inductor's state is one number, because the current is a function of the flux linkage. A hysteretic core's is not: half an amp is one flux on the way up and a different flux on the way down, and there is no function of the current that returns the flux. So the march's state vector gains twenty-four more numbers, one per play operator, and the Newton loop is forbidden to touch them. The circuit and the bench then agree on the loss to three parts in ten million — one integral taken at two wires, the other inside the material.
The distribution the bench cannot see
Six rungs of this ladder assumed a uniform density of operator thresholds, and the reason given was that a uniform density makes the small-signal law come out cubic. That reason is weaker than it looks: every density finite at the origin does the same. Matched on a measured coercivity, four distributions whose spreads differ by 2.5 times give the same remanence to 0.6 per cent, the same loop area to 1.0, and the same branch-slope ratio to 0.54 — and small-signal exponents from 2.81 to 3.81. The major loop cannot see the shape and the small signal cannot see anything else.
The boundary that is a starting point
A wound part with a stable operating point at 88.8 degrees and an ignition temperature at 191.1 will never reach the second, because nothing takes it there. Marched in time rather than solved for its steady states, the same equation says what does: a trajectory starting at 189.6 degrees settles back and one starting at 192.6 leaves the material's range in twelve seconds — two starts three kelvin apart. And an overload of four times the normal loss is survivable for ever, while seven times is survivable for seventeen minutes.
One dissipation, two exponents
The core this ladder built takes two numbers — a threshold spread and the fraction of the magnetisation that follows the field with no threshold — and seven rungs moved the first and left the second at 0.55 without ever saying why. The first decides how much loss there is: area, coercivity and remanence are all exactly proportional to it over four decades, at 0.625961 joules per cubic metre, 0.449775 and 1.130408 millitesla per ampere-metre of spread, the last two of which are closed forms. The second decides nothing about the loss at all — it is single-valued, so it contributes exactly zero to the loop area, to twelve digits — and it moves the Steinmetz exponent from 1.5042 to 2.9860.