Measuring with 50 mΩ of lead in each wire
Drawn above at its default parameters, which is almost never how an essay calls it. A placement states the numbers that essay is arguing about, so the figure a reader meets is about that argument rather than about the generator — 98% of the placements on this site pass one, and the phase that raised that number from 12% found eight captions describing a figure the page was not showing.
At those defaults the edge it states is two wires fail below 10 Ω — the right-hand slot
of the caption strip, which on this site is never used for anything else, and which is read
back out of the drawing above rather than out of the code that wrote it.
It belongs to Measurement, which is a circuit on a circuit, which is to say a change to it is a
change to lib/figures/instruments.js.
It takes a slider on resistance of each lead (milliohms) with 6 settings,
and every one of them has passed the same assertions as the frame above — a figure whose
circuit stops doing what its caption says at any setting stops the build.
Called by 7 essays
which is the blast radius of changing it
Two terminals measure the leads as well
Fifty milliohms in each lead makes a two-wire measurement one per cent high at ten ohms, ten per cent high at one ohm, and a hundred per cent high at a tenth. Not approximately — the reading is the resistance plus the leads, and below about ten ohms most of what is being reported is the wire between the instrument and the thing.
The millivolts in the wire
Ten millimetres of one-ounce copper is five milliohms and ten nanohenries, and if a hundred-milliamp load and a ten-millivolt sensor both return through it, half a millivolt of somebody else's current is added to the reading — five per cent of it, before anything has been amplified. Above 79.6 kilohertz the error rises a decade per decade with no ceiling, and shortening the shared run moves the whole curve down and the corner not at all.
The rejection four resistors decide
Measuring a ten-millivolt sensor against a ground that somebody else's hundred milliamps is also using puts five hundred microvolts of their current into the reading. Subtracting the two ends of that conductor with a difference amplifier removes it — by 53.99 decibels with one-tenth-per-cent resistors, against a closed form of 53.98, which is a factor of five hundred and not a removal. The amplifier has nothing to do with it: the number is one plus the gain over four times the resistor tolerance.
The ammeter that is a resistor
Every direct measurement of a current is a measurement of a voltage across something the current was made to flow through, so the instrument has two errors pointing opposite ways: a larger shunt changes the current, a smaller one leaves less for the amplifier's offset to be compared with. Written in the burden voltage they are the burden over the supply and the amplifier's offset over the burden, and the best of them is at the geometric mean — 7.75 millivolts on a twelve-volt rail, with a worst-case error of 0.129 per cent. Neither number contains a resistance, and neither contains the current: ten milliamps and a hundred amps want the same 7.75 millivolts.
The current that does not reach the input
A teraohm across a board from a fifteen-volt rail is fourteen millivolts of error through a gigohm source, and a humid morning takes that resistance down two decades. A ring held at the input's own potential leaves a nanovolt — proportional to the signal rather than to the rail, so an offset has become a gain error of one part in a billion — and the same wire multiplies the input resistance by the loop gain, which makes it 10¹⁸ Ω at direct current and 10¹² Ω at a megahertz.
The leads that are in the bridge
A strain gauge on the end of two long wires cannot be told from a strain gauge under load: both leads in the changing arm is bit for bit the same netlist as a quarter bridge whose fractional change is larger by twice the lead over the gauge, which at 350 milliohms on a 350 ohm gauge is 999 microstrain that is not there. Moving one of those leads into the arm beside it leaves the output at exactly zero for every lead resistance drawn, and turns a twenty-kelvin drift of 76.8 microstrain into 0.077. That factor is two over the strain being read — 999 at a thousand microstrain and 9990 at two hundred — and it costs 0.100 per cent of sensitivity.
The voltmeter four wires do not remove
A four-terminal measurement is described everywhere as removing the leads from the answer. It moves them. What is left is the voltmeter's own input resistance, and it grows with the resistance being measured rather than shrinking: with a ten-megohm voltmeter and fifty milliohms of lead, the four-wire reading is 0.0100 per cent low at a kilohm, where the two-wire reading is exactly right — 1.8 × 10⁻¹² — because its lead error and its loading error cancel. Above 707 Ω the two-wire arrangement is the more accurate of the two at every resistance.