Generator

1000 µF across a 100 Ω load, rectified from 17 V peak

The output sits at 15.69 V with 1.331 V of ripple, against the 1.569 V the expression I/2fC gives — 15.1% high, because the capacitor is being recharged for part of the cycle rather than discharging throughout it. The lower panel is why: the diode conducts for 28.8° of each half cycle and carries 2.10 A at the peak, which is 13.4 times the 157 mA the load draws.
1000 µF across a 100 Ω load, rectified from 17 V peakThe output sits at 15.69 V with 1.331 V of ripple, against the 1.569 V the expression I/2fC gives — 15.1% high, because the capacitor is being recharged for part of the cycle rather than discharging throughout it. The lower panel is why: the diode conducts for 28.8° of each half cycle and carries 2.10 A at the peak, which is 13.4 times the 157 mA the load draws.1416180102030output (volts)where I/2fC says the trough iswhere it isthe rectified sinusoid0120102030time (milliseconds)current in one diode (amperes)peak 2.10 A · 13.4× the load's direct currentsolved, then checked28.8° of conduction, 13.4× crest

Drawn above at its default parameters, which is almost never how an essay calls it. A placement states the numbers that essay is arguing about, so the figure a reader meets is about that argument rather than about the generator — 98% of the placements on this site pass one, and the phase that raised that number from 12% found eight captions describing a figure the page was not showing.

At those defaults the edge it states is 28.8° of conduction, 13.4× crest — the right-hand slot of the caption strip, which on this site is never used for anything else, and which is read back out of the drawing above rather than out of the code that wrote it. It belongs to Circuits that do a job, and the range they do it over, which is to say a change to it is a change to lib/figures/applied.js. It takes a slider on reservoir capacitance (microfarads) with 5 settings, and every one of them has passed the same assertions as the frame above — a figure whose circuit stops doing what its caption says at any setting stops the build.

Called by 9 essays

which is the blast radius of changing it

The direct voltage that is a sawtooth

A rectifier and a reservoir capacitor make what everybody calls a direct voltage. Marched with the diodes in the netlist, a thousand microfarads across a hundred ohms gives 15.69 volts with 1.33 volts of ripple on it, against the 1.57 the textbook expression predicts. The expression is high by the fraction of the cycle the diode conducts for — measured at 0.94 to 0.96 of it across two sweeps — and it has no opinion at all about the quantity that actually sizes the transformer, which is a peak diode current 13.4 times the current the load draws.

Circuits that do a job, and the range they do it over

A source below a frequency

A five-volt regulator's output impedance is 0.43 milliohms, which is the number a datasheet quotes. It has doubled by 4.8 hertz, is ten times worse by 27, and reaches 1.95 ohms at ten kilohertz — four and a half thousand times its own specification, and higher there than the same circuit with its feedback loop cut. Two routes to that curve, sharing only the netlist, agree to a part in ten to the thirteenth.

Circuits that do a job, and the range they do it over

The first cycle, which no steady state contains

Every number this field computes about a rectifier — the ripple, the crest factor, the conduction angle, the power factor — is read from the settled state, and the march that produces them starts from an empty capacitor and throws the first cycle away. That first conduction carries 32.4 amperes against a repetitive peak of 1.23, it is 26 times larger than anything the circuit ever does again, and how large it is depends on when somebody's hand closed the switch.

Power, and the part that does no work

The protection that is gone by the second time

An inrush thermistor is ten ohms cold and holds the first cycle down; then the load current warms it and it settles at 83 degrees and 1.94 ohms, which is 19 per cent of what was bought. That is the design working. It is also a part that takes 198 seconds to recover half its cold resistance, against a reservoir capacitor that empties in tens of milliseconds — so a mains dip in that window hands the rectifier an unlimited inrush into an empty capacitor, which is the exact event the part is on the bill of materials for.

Power, and the part that does no work

The current that sizes the transformer

A reservoir's crest factor is 13.374 at a thousand microfarads and the winding is not sized by it. The root-mean-square of the same marched current is 3.0069 times the load's direct current, so the copper dissipates 9.0417 times what it would carrying the direct current alone — and the two ratios diverge, from 3.04 apart at 220 microfarads to 5.95 apart at 4700. The expression for the mean output is wrong in three places whose signs differ, and at 313.9 microfarads they cancel to six microvolts while the ripple expression inside it is still 32.3 per cent high.

Circuits that do a job, and the range they do it over

The ripple that arrives as a comb

The rejection essay multiplied two numbers: 1.331 volts of reservoir ripple and the regulator's 36.0 decibels of rejection at a hundred hertz, for 21 millivolts at the output. The ripple is a sawtooth, a comb of lines at every multiple of a hundred hertz, and the rejection worsens at twenty decibels a decade — so the second line arrives at nearly the size of the first, and the third too. Summed with their phases, the output is 60.62 millivolts, 2.87 times the estimate, and the hundred-hertz line carries only 23.4 per cent of it. A reservoir twenty-one times larger cuts the rail's ripple 14.8 times and the regulated ripple 5.95.

Circuits that do a job, and the range they do it over

The resistance that lowers the ripple

Two earlier essays here marched a reservoir with a perfect capacitor. A real one has tens of milliohms of its own, and the obvious expectation — that the resistive step it adds makes the ripple worse — is wrong in an interesting direction: the resistance also limits the charging current, and the ripple has an interior minimum of 1.3303 V at 17.0 mΩ, below the 1.3312 V a perfect capacitor gives. What the resistance buys monotonically is the peak current, which falls from 13.37 times the load's to 6.55 at an ohm, for 380 mV of mean output.

Circuits that do a job, and the range they do it over

The resistance that belongs in the winding

A reservoir capacitor's series resistance lowers the ripple to a minimum of 1.3303 V at 17 mΩ and raises it past that. The same resistance moved into the transformer's winding limits the peak current by the same amount — the crest factor agrees to two parts in a thousand at every value from a milliohm to an ohm — and the minimum is gone: the ripple falls throughout, to 1.172 V at an ohm against 1.711 V in the capacitor. The two resistances each carry a current the other does not, and that one asymmetry decides where a deliberate one should go.

Circuits that do a job, and the range they do it over

Two capacitors that are one

Two identical reservoir capacitors in parallel are not a new circuit to be marched: 500 µF at 60 mΩ twice gives 1.330303 V of ripple and so does 1000 µF at 30 mΩ once, to the sixth decimal. So a pair against one part of the same capacitance is one curve read at two resistances, and the pair always sits at the lower one — which lowers the ripple only past the curve's minimum, 709 mV against 728 at 100 mΩ a part, and raises the peak current at every value, a crest factor of 14.41 against 12.61. Mismatch the pair and the current still divides by capacitance, so a part with twice the resistance carries 2% less current and 1.93 times the heat.

Circuits that do a job, and the range they do it over

Every generator