The millivolts in the wire, which are nobody's signal

computed by solving, not by drawing at 145 frequencies. A 10 mm run of one-ounce copper carries the return of a 100 mA load and the reference of a 10 mV sensor. Its 5.00 mΩ and 10.0 nH put 500.0 µV in series with the sensor at low frequency — 5.00% of the reading — rising a decade per decade above 79.6 kHz until at 1.59 MHz the error is the whole signal. The full solve and the interfering current times the shared impedance agree to 4.4e-7. The slider is the length of the shared run: both the resistance and the inductance are proportional to it, so every point on the curve moves down together and the corner stays at 79.6 kHz.
The millivolts in the wire, which are nobody's signalcomputed by solving, not by drawing at 145 frequencies. A 10 mm run of one-ounce copper carries the return of a 100 mA load and the reference of a 10 mV sensor. Its 5.00 mΩ and 10.0 nH put 500.0 µV in series with the sensor at low frequency — 5.00% of the reading — rising a decade per decade above 79.6 kHz until at 1.59 MHz the error is the whole signal. The full solve and the interfering current times the shared impedance agree to 4.4e-7. The slider is the length of the shared run: both the resistance and the inductance are proportional to it, so every point on the curve moves down together and the corner stays at 79.6 kHz.100µ1m10m100m1101001k10k100k1M10M100Mfrequency of the interfering current (hertz)error added to the reading (volts)10 mV — the signal being measured79.6 kHz — Rg/2πLg1.59 MHz — the error is the signalshared run10 mmits resistance5.00 mΩits inductance10.0 nHinterfering current100 mAthe signal10 mVerror at 100 Hz500.0 µVas large as the signal1.59 MHzsolved, then checked — the return in the netlistthe signal is lost by 1.59 MHz

Drawn above at its default parameters, which is almost never how an essay calls it. A placement states the numbers that essay is arguing about, so the figure a reader meets is about that argument rather than about the generator — 98% of the placements on this site pass one, and the phase that raised that number from 12% found eight captions describing a figure the page was not showing.

At those defaults the edge it states is the signal is lost by 1.59 MHz — the right-hand slot of the caption strip, which on this site is never used for anything else, and which is read back out of the drawing above rather than out of the code that wrote it. It belongs to Measurement, which is a circuit on a circuit, which is to say a change to it is a change to lib/figures/instruments.js. It takes a slider on length of the shared return (millimetres) with 6 settings, and every one of them has passed the same assertions as the frame above — a figure whose circuit stops doing what its caption says at any setting stops the build.

Called by 4 essays

which is the blast radius of changing it

The millivolts in the wire

Ten millimetres of one-ounce copper is five milliohms and ten nanohenries, and if a hundred-milliamp load and a ten-millivolt sensor both return through it, half a millivolt of somebody else's current is added to the reading — five per cent of it, before anything has been amplified. Above 79.6 kilohertz the error rises a decade per decade with no ceiling, and shortening the shared run moves the whole curve down and the corner not at all.

Measurement, which is a circuit on a circuit

The rejection four resistors decide

Measuring a ten-millivolt sensor against a ground that somebody else's hundred milliamps is also using puts five hundred microvolts of their current into the reading. Subtracting the two ends of that conductor with a difference amplifier removes it — by 53.99 decibels with one-tenth-per-cent resistors, against a closed form of 53.98, which is a factor of five hundred and not a removal. The amplifier has nothing to do with it: the number is one plus the gain over four times the resistor tolerance.

Measurement, which is a circuit on a circuit

The ammeter that is a resistor

Every direct measurement of a current is a measurement of a voltage across something the current was made to flow through, so the instrument has two errors pointing opposite ways: a larger shunt changes the current, a smaller one leaves less for the amplifier's offset to be compared with. Written in the burden voltage they are the burden over the supply and the amplifier's offset over the burden, and the best of them is at the geometric mean — 7.75 millivolts on a twelve-volt rail, with a worst-case error of 0.129 per cent. Neither number contains a resistance, and neither contains the current: ten milliamps and a hundred amps want the same 7.75 millivolts.

Measurement, which is a circuit on a circuit

The corner the instrument has no part in

Three rungs of this argument measured a three-amplifier instrumentation amplifier's rejection at direct current and found 95 dB, of which the resistors' matching decides one part and the amplifiers' own mismatch another. Connect it to a source with a kilohm of imbalance and ten picofarads at each input and the rejection has a corner at 290 Hz and falls twenty decibels a decade after it — reaching 84 dB at a kilohertz on an instrument that is still doing 95. What converts common mode to differential is the difference of two time constants, and the cure is a capacitor on the quiet input.