Generator

The best shunt drops 7.75 mV, whatever the current is

computed by solving, not by drawing. Two errors on one axis, both from solved networks: the shunt's own drop, which lowers the current that was to be measured, and the amplifier's 5.0 µV of offset divided by the voltage the shunt develops. The first rises with the burden voltage and the second falls, so the worst case has an interior minimum at 7.7460 mV — the geometric mean of the offset and the 12 V supply — where the error is 0.1291%, being twice the root of the offset over the supply. Neither the shunt's resistance nor the current appears in either number: at 1 A the answer is 7.75 mΩ, and at a hundred times the current it is the same burden voltage across a hundredth of the resistance. What does depend on the current is the 7.7 mW the shunt then dissipates, and 40 K of self-heating at 50 ppm/K is 0.2000% on its own. The third curve is the shunt's own Johnson noise in a kilohertz of measurement bandwidth, as a fraction of the current: it is 4.5e-6% at the best burden and is the only line here that moves with the current at all, falling as one over its square root — so above about an ampere it leaves the bottom of these axes entirely and is drawn nowhere rather than flattened onto the floor.
The best shunt drops 7.75 mV, whatever the current iscomputed by solving, not by drawing. Two errors on one axis, both from solved networks: the shunt's own drop, which lowers the current that was to be measured, and the amplifier's 5.0 µV of offset divided by the voltage the shunt develops. The first rises with the burden voltage and the second falls, so the worst case has an interior minimum at 7.7460 mV — the geometric mean of the offset and the 12 V supply — where the error is 0.1291%, being twice the root of the offset over the supply. Neither the shunt's resistance nor the current appears in either number: at 1 A the answer is 7.75 mΩ, and at a hundred times the current it is the same burden voltage across a hundredth of the resistance. What does depend on the current is the 7.7 mW the shunt then dissipates, and 40 K of self-heating at 50 ppm/K is 0.2000% on its own. The third curve is the shunt's own Johnson noise in a kilohertz of measurement bandwidth, as a fraction of the current: it is 4.5e-6% at the best burden and is the only line here that moves with the current at all, falling as one over its square root — so above about an ampere it leaves the bottom of these axes entirely and is drawn nowhere rather than flattened onto the floor.10µ100µ1m10m100m110µ100µ1m10m100m110burden voltage across the shunt (volts)error in the current, as a fraction of itthe shunt's own dropthe amplifier's offsetbest at 7.75 mV0.129% — and no betterthe shunt's own noise, in a kilohertzcurrent measured1 Asupply12 Vamplifier offset5.0 µVbest burden7.7460 mV√(Vₒₛ·V)7.7460 mVshunt that gives it7.75 mΩerror there0.1291%2√(Vₒₛ/V)0.1291%dissipation there7.75 mWits noise, 1 kHz band4.5e-6%40 K of self-heat0.2000%solved, then checked — the circuit solved with the instrument in itno shunt beats 0.129% on a 12 V rail

Drawn above at its default parameters, which is almost never how an essay calls it. A placement states the numbers that essay is arguing about, so the figure a reader meets is about that argument rather than about the generator — 98% of the placements on this site pass one, and the phase that raised that number from 12% found eight captions describing a figure the page was not showing.

At those defaults the edge it states is no shunt beats 0.129% on a 12 V rail — the right-hand slot of the caption strip, which on this site is never used for anything else, and which is read back out of the drawing above rather than out of the code that wrote it. It belongs to Measurement, which is a circuit on a circuit, which is to say a change to it is a change to lib/figures/instruments.js. It takes a slider on current being measured (amps) with 5 settings, and every one of them has passed the same assertions as the frame above — a figure whose circuit stops doing what its caption says at any setting stops the build.

Called by 5 essays

which is the blast radius of changing it

The ammeter that is a resistor

Every direct measurement of a current is a measurement of a voltage across something the current was made to flow through, so the instrument has two errors pointing opposite ways: a larger shunt changes the current, a smaller one leaves less for the amplifier's offset to be compared with. Written in the burden voltage they are the burden over the supply and the amplifier's offset over the burden, and the best of them is at the geometric mean — 7.75 millivolts on a twelve-volt rail, with a worst-case error of 0.129 per cent. Neither number contains a resistance, and neither contains the current: ten milliamps and a hundred amps want the same 7.75 millivolts.

Measurement, which is a circuit on a circuit

The ammeter that is not in the circuit

A shunt measures a current by putting a resistance in the circuit, and every objection to it follows from that. A current transformer puts nothing in the circuit at all — a thousand-turn secondary reflects twelve microhms into the primary — and charges for it in a different currency: no response at direct current, a ratio error that stops falling at one minus the coupling, and a phase error of half a degree at fifty hertz that costs eighteen per cent of a power reading at a power factor of 0.05.

Measurement, which is a circuit on a circuit

The optimum that hands back a bandwidth

The best burden voltage across a shunt is 7.75 mV and contains neither the current nor the resistance, which is what made it worth having. A shunt has two nanohenries whatever it is made of, so holding the burden fixed fixes the resistance at u*/I — and the corner R/2πL then falls in exact proportion to the current: 6.16 MHz at a tenth of an ampere, 616 kHz at one, 6.16 kHz at a hundred. A resistor and a 258.2 pF capacitor across it, found by search on the solved response, flatten the reading to 8×10⁻⁵ per cent across six decades.

Measurement, which is a circuit on a circuit

The rail that is an input error

The best burden voltage across a shunt is the geometric mean of the amplifier's offset and the supply, and moving the shunt to the high side does not change that form — it changes what the offset is. A hundred-decibel amplifier on a twelve-volt rail turns the rail into 120 µV of equivalent input error, twenty-four times its own five, so the optimum moves from 7.75 mV and 0.129 per cent to 38.73 mV and 0.644. The two are equal only at 128 dB, and with the common-mode term removed the optimum returns to the low-side value exactly.

Measurement, which is a circuit on a circuit

The resistance that depends on the reading

Three of a shunt's errors are free of the current being measured, which is the whole content of the burden-voltage optimum. The fourth is not: the shunt dissipates, warms, and its resistance rises — so the divisor the reading uses is a function of the reading. Solved as a fixed point it agrees with R₀/(1 − αθI²R₀) to 2×10⁻¹⁶, and along the optimum, where the dissipation is I·u* rather than I²R, the error is the FIRST power of the current: 7.75 ppm at an ampere, 775 at a hundred, fitted exponent 1.0007.

Measurement, which is a circuit on a circuit

Every generator