Where a switch is a switch: a band, and the 6.43 MHz at which it closes
Drawn above at its default parameters, which is almost never how an essay calls it. A placement states the numbers that essay is arguing about, so the figure a reader meets is about that argument rather than about the generator — 98% of the placements on this site pass one, and the phase that raised that number from 12% found eight captions describing a figure the page was not showing.
At those defaults the edge it states is a band, shut above 6.43 MHz — the right-hand slot
of the caption strip, which on this site is never used for anything else, and which is read
back out of the drawing above rather than out of the code that wrote it.
It belongs to Where the models stop, which is to say a change to it is a
change to lib/figures/limits.js.
It takes a slider on capacitance across the open switch (picofarads) with 7 settings,
and every one of them has passed the same assertions as the frame above — a figure whose
circuit stops doing what its caption says at any setting stops the build.
Called by 11 essays
which is the blast radius of changing it
A band rather than an edge
Every other boundary in this collection is one-sided: a model is true below a frequency, or below an amplitude. A switch is a switch only for loads between 49.5 ohms and 1.01 megohms — bounded at both ends by the same part — and the upper end is a frequency as well as a resistance, so the band narrows as the frequency rises and shuts completely at 6.43 megahertz, above which no load resistance at all will do.
The same filter a thousand times larger
Multiply every resistance by a thousand and divide every capacitance by a thousand and the response does not change — not approximately, but to a part in ten to the fifteenth, which is the last bits of a double. So a designer has a free parameter that the design says nothing about, and what decides it is the two quantities that refuse to scale: fifty ohms of amplifier output resistance at one end and two picofarads of stray at the other. Between them the realisation survives over three decades of impedance level and nowhere else.
The heat a recovery leaves behind
The essay below this one measured how much current a diode conducts backwards and for how long, and stopped there. Both numbers are multiplied by a voltage somewhere, and the surprise is where: while the junction is still conducting it holds almost nothing, so nine tenths of the energy is dissipated in the transistor pulling the current down and not in the diode. Repeat it a hundred thousand times a second and it is 1.5 watts, the lifetime rises with temperature, and above 1.28 megahertz the diode's own loop has no fixed point at all.
The width no load can change
A switch's band was drawn against a load resistor and closed at 6.43 megahertz. Put a hold capacitor where the resistor was and the band changes axis and shape — a diagonal below 318 hertz, a floor of 495 picofarads above it — and stays exactly as wide: 1.8083 decades at 100 kilohertz for both loads, closing at 6.43 megahertz for both. Count the capacitor's error as a magnitude, as the resistor's always was, and the band appears to stay open to 91.6 megahertz. That extra room is 8.11 degrees of lag the count cannot see.
Where an open switch leaks to
A lone switch has a band whose width no load can change, because its open state leaks into the load. In a multiplexer the seven open channels leak into a node the selected channel holds, so the load leaves the answer and the source takes its place: one per cent of leak at 91.0 megahertz from buffered sources and 901 kilohertz from fifty ohms, moving as the first power of the tolerance rather than the second. Adding the channels' capacitance into one forty-picofarad switch puts it at 804 kilohertz, near the fifty-ohm figure by coincidence and a hundred and thirteen times low for a buffered one.
The capacitance a third switch moves
A changeover's open channel leaks into the source of the channel that is closed, so its isolation into fifty ohms falls from 643 megahertz with a buffered source to 6.34 megahertz with a fifty-ohm one. Put a third switch to ground between two series switches and the leak lands on half an ohm of closed switch instead: 814, 643 and 2,240 megahertz from sources of nothing, fifty ohms and a kilohm, rising forty decibels a decade where a changeover's rises twenty. The price is the shunt switch's own capacitance, moved under the closed path, which makes the T one per cent wrong as a waveform at 6.59 megahertz beside the changeover's 6.61.
The half a switch keeps
The rung below found that charging a capacitor from a step loses half the delivered energy whatever the resistance, and that a ramp takes the loss down as 2τ/T with no floor. A staircase of N settled risers costs one Nth of the step, exact to four parts in a million, and the law ends at a dwell of 5.272 time constants. A switch is the other half of the same product and buys nothing at all: with the supply held at five volts and the channel conductance ramped over a thousand time constants, the loss is 1.00000000 of ½CV².
The floor below any load
A switch of half an ohm closed and a hundred megohms open is within one per cent of ideal for loads between two edges, and the edges close on each other as the tolerance tightens. At direct current they meet at 70.71 parts per million, into 7.07 kilohms: no load makes that switch better, which is 13.79 bits and a boundary with no frequency in it. A T of three such switches has no best load at all. Its error falls with the load towards five parts per billion — the square of the lone switch's resistance ratio rather than its root — and reaches ten only into two hundred megohms. Into the 7.07 kilohms that suited one switch, the T is worse than one switch.
The shunt switch the source sizes
A T is two series switches and a third to ground, and it is always drawn with three of the same part. The shunt switch pulls its own size two ways: larger, it holds the open node harder; larger, it hangs more capacitance on the closed path. The size at which the band closes latest is a balance of the two — the fourth root of 2/ε times √(Rₒₙ/(Rₛ + Rₒₙ)) — when the closed state is counted as an amplitude — 3.8 times a series switch from a buffered source, a third of one from fifty ohms, a twelfth from a kilohm — and it buys a band 3.4, 2.7 and 13 times wider. Counted as a waveform the root of ε goes, and from a buffered source the best shunt is exactly the series switch.
The resistance that bends the signal
A switch of half an ohm and a hundred megohms has a floor of 70.71 parts per million, 13.79 bits, because its on-resistance and its off-resistance cannot both be small beside one load. Most of that floor is a gain error, and a gain error calibrates away. Give the on-resistance a realistic ten per cent of movement across the signal range and the uncalibrated floor slips to 74.16 parts per million, while the part no calibration can touch — the curvature — balances the leak at 13.89 parts per million, 16.14 bits, into 1.39 kilohms. The floor was never set by the on-resistance. It is set by how much the on-resistance moves, as its square root.
The leak no switch can hold
A T of three switches reaches five parts per billion because its shunt switch holds the node a leak has to cross. A junction leakage does not cross anything: it flows out of the outer switch's terminal straight into the load. With 100 picoamperes of it at 25 °C, doubling every ten kelvin, the T's floor is 9.998 parts per million rather than five parts per billion — 16.61 bits, not 27.6 — and it has a best load again, at 100 kilohms. A lone switch loses nothing at room temperature. Above 91.4 °C, where the junction current reaches the off-resistance's conductance at one volt, the T is worse than one switch.