The heat a core makes against the heat its path removes, and the two temperatures where they are equal

computed by solving, not by drawing. The rising straight line is what the thermal path can carry away at a temperature — (T − 25)/45 watts, a line because a thermal resistance is a resistance. The curve is what the wound part actually dissipates at that temperature, marched from a hysteresis loop at a material whose saturation flux and permeability both move with temperature. They cross twice. The lower crossing at 88.8 degrees is the operating point and its loop gain is -0.192 — negative, so the core is a stabilising feedback and not a destabilising one. The upper crossing at 191.1 degrees is an ignition temperature: above it the part cannot get rid of what it makes. The slider moves the thermal resistance.
The heat a core makes against the heat its path removes, and the two temperatures where they are equalcomputed by solving, not by drawing. The rising straight line is what the thermal path can carry away at a temperature — (T − 25)/45 watts, a line because a thermal resistance is a resistance. The curve is what the wound part actually dissipates at that temperature, marched from a hysteresis loop at a material whose saturation flux and permeability both move with temperature. They cross twice. The lower crossing at 88.8 degrees is the operating point and its loop gain is -0.192 — negative, so the core is a stabilising feedback and not a destabilising one. The upper crossing at 191.1 degrees is an ignition temperature: above it the part cannot get rid of what it makes. The slider moves the thermal resistance.010020030040050100150200core temperature, degrees Celsiuswatts89 °C, stable191 °C, ignitionwhat the part dissipateswhat the path removesflux swing120 mTthermal resistance45 K/Wambient25 °Coperating point88.8 °Cloop gain there-0.192dissipation1.417 Wignition191.1 °Cloop gain there120.2solved, then checked — a temperature is a fixed point89 °C, gain -0.19

Drawn above at its default parameters, which is almost never how an essay calls it. A placement states the numbers that essay is arguing about, so the figure a reader meets is about that argument rather than about the generator — 98% of the placements on this site pass one, and the phase that raised that number from 12% found eight captions describing a figure the page was not showing.

At those defaults the edge it states is 89 °C, gain -0.19 — the right-hand slot of the caption strip, which on this site is never used for anything else, and which is read back out of the drawing above rather than out of the code that wrote it. It belongs to Two windings, and the band between them, which is to say a change to it is a change to lib/figures/magnetics.js. It takes a slider on thermal resistance, K/W with 6 settings, and every one of them has passed the same assertions as the frame above — a figure whose circuit stops doing what its caption says at any setting stops the build.

Called by 6 essays

which is the blast radius of changing it

The protection that is gone by the second time

An inrush thermistor is ten ohms cold and holds the first cycle down; then the load current warms it and it settles at 83 degrees and 1.94 ohms, which is 19 per cent of what was bought. That is the design working. It is also a part that takes 198 seconds to recover half its cold resistance, against a reservoir capacitor that empties in tens of milliseconds — so a mains dip in that window hands the rectifier an unlimited inrush into an empty capacitor, which is the exact event the part is on the bill of materials for.

Power, and the part that does no work

The degrees a thermocouple cannot see

Every thermal answer in this collection has been one temperature, and a core makes its heat in its volume and loses it from a surface, so it has two. Solved as a conduction problem, a twenty-millimetre core in still air is 2.59 kelvin hotter in the middle than on the outside — 2.9 per cent of a ninety-kelvin rise, which is why the lumped answer has been good enough. Cool the same core on a plate and the gradient does not shrink; it grows to 3.37 kelvin and becomes 78 per cent of what is left.

Power, and the part that does no work

The loop gain one temperature understates

Every thermal loop gain this collection has computed was computed at a single temperature, because a lumped fixed point has only one — and the essay that measured the gradient inside a core recorded, without measuring it, that this makes each of those numbers a lower bound. It is a lower bound by three per cent where a ferrite usually sits and by thirty-eight per cent at the well-cooled end, always in the direction that makes the part safer than the calculation said. The obvious candidate for what decides it is refused: three geometries at one Biot number are 3.3 times apart.

Power, and the part that does no work

The loss that depends on what it causes

Every thermal figure in this collection has had the power handed in. A ferrite's has no business being: its saturation flux falls with temperature, its permeability rises, and both move the loss. Closing that loop makes the temperature a fixed point rather than a product — and the fixed point has a stable root at 89 degrees whose loop gain is negative, an ignition root at 191 whose loop gain is 120, and a thermal resistance of 183 kelvin per watt at which the two touch and neither exists.

Two windings, and the band between them

The sensor inside its own answer

A junction driven from a current source cannot run away, because its forward voltage falls with temperature and its loop gain is therefore negative. What that costs is a thermometer that is warmer than what it is measuring by 4.26 kelvin at ten milliamperes, and — the part a calibration cannot remove — under-reports every change in ambient by 9,584 parts per million, because the sense current's own dissipation falls as the reading rises. Calibrated at 25 degrees, it is out by 583 millikelvin at 85.

Devices, and the amplitude they stop being linear at

The boundary that is a starting point

A wound part with a stable operating point at 88.8 degrees and an ignition temperature at 191.1 will never reach the second, because nothing takes it there. Marched in time rather than solved for its steady states, the same equation says what does: a trajectory starting at 189.6 degrees settles back and one starting at 192.6 leaves the material's range in twelve seconds — two starts three kelvin apart. And an overload of four times the normal loss is survivable for ever, while seven times is survivable for seventeen minutes.

Two windings, and the band between them