AC coupling — the series
-
The corner that says nothing about an edge
An AC-coupled input is sold on a low-frequency corner, and a corner is a statement about steady sinusoids. What an instrument is usually shown is a pulse, and for a pulse the number is a sag: a hundred-millisecond pulse through a 0.159 hertz corner comes out 9.5 per cent shorter than it went in. A one per cent flat top needs a pulse rate 625 times the corner, which is a constant with no component in it — and above fifty per cent duty an AC-coupled pulse never reaches half its own height at all.
-
The rejection two capacitors lose at their corner
AC-couple both inputs of a differential instrument and the two coupling networks become part of its common-mode path. Two 1 µF capacitors one per cent apart turn common mode into difference at exactly half their mismatch at their shared corner — 46.0 dB of rejection at 0.159 Hz, from a pair that is perfect at direct current and far above. Behind a 90 dB amplifier they decide the instrument's rejection over five decades around that corner. A 10 V common-mode step arrives as a 36.8 mV differential pulse one time constant later. Four hundred pairs of 20 per cent electrolytics reject a median 25 dB. Coupling the difference instead of each side removes the dip and hands the common mode to the amplifier.
-
The second capacitor, and the tail that changes sign
One coupling stage turns a pulse into a sagging top and an undershoot that returns to zero from below. Add a second stage with the same one-second time constant and a half-second pulse sags to 0.303 of itself instead of 0.607, undershoots to −0.697, crosses zero 2.27 s after it began and overshoots positive before settling. The step response becomes (1 − t/τ)·exp(−t/τ), through zero at exactly one time constant and down to −e⁻² at two. The reason is arithmetic: one capacitor removes the waveform's area, two remove its area and its first moment, and a pulse with a one-signed tail cannot have both. Built to the same stated corner, two stages still sag 1.29 times as fast, and a 1% flat top needs a pulse rate 806 times the corner rather than 625.
-
Two coupling stages without a buffer
Hang a second coupling stage directly on the first, with equal parts, and the pair's denominator gains a third time constant — the first resistor carrying the second capacitor's current. The poles spread from a double pole to −0.382 and −2.618 per time constant, a half-second pulse's top sags to 0.175 instead of the buffered pair's 0.303, and the sag rate is exactly 2 + 1/k per time constant for a second stage k times the first's impedance — the sum of the two short-circuit time constants. The tail still crosses zero, because the two zeros at the origin are untouched, and a step's lowest point is still at exactly twice its zero crossing. Then a reversal: specified by the overall corner rather than by the parts, the loaded pair sags only 1.12 times as fast as one stage and undershoots 7.6% rather than 13.5% — the buffer the cascade essay assumed makes the specified input worse.
-
The ring a blocking capacitor buys
A series capacitor in front of a transformer stops its flux from walking: a 55%-duty drive that walks a bare core by 0.40 units of volt-time a period settles within a few dozen periods once the capacitor takes the drive's average. The price is a second-order high-pass with the magnetising inductance, and an inductance lets its poles go complex where two resistive coupling stages never could. Between equal resistances the damping cannot fall below 1/√2, and the poles are complex only for a capacitor between 0.17 and 5.8 times L/R². From a stiff driver the damping is √(L/C)/2R and has no floor: a capacitor large enough to make the droop small — the droop is 1/RC, the capacitor's and not the transformer's — makes the tail ring, from one zero crossing at a tenth of L/R² to thirty-five at a hundred.