Current sensing — the series
-
The ammeter that is a resistor
Every direct measurement of a current is a measurement of a voltage across something the current was made to flow through, so the instrument has two errors pointing opposite ways: a larger shunt changes the current, a smaller one leaves less for the amplifier's offset to be compared with. Written in the burden voltage they are the burden over the supply and the amplifier's offset over the burden, and the best of them is at the geometric mean — 7.75 millivolts on a twelve-volt rail, with a worst-case error of 0.129 per cent. Neither number contains a resistance, and neither contains the current: ten milliamps and a hundred amps want the same 7.75 millivolts.
-
The ammeter that is not in the circuit
A shunt measures a current by putting a resistance in the circuit, and every objection to it follows from that. A current transformer puts nothing in the circuit at all — a thousand-turn secondary reflects twelve microhms into the primary — and charges for it in a different currency: no response at direct current, a ratio error that stops falling at one minus the coupling, and a phase error of half a degree at fifty hertz that costs eighteen per cent of a power reading at a power factor of 0.05.
-
The optimum that hands back a bandwidth
The best burden voltage across a shunt is 7.75 mV and contains neither the current nor the resistance, which is what made it worth having. A shunt has two nanohenries whatever it is made of, so holding the burden fixed fixes the resistance at u*/I — and the corner R/2πL then falls in exact proportion to the current: 6.16 MHz at a tenth of an ampere, 616 kHz at one, 6.16 kHz at a hundred. A resistor and a 258.2 pF capacitor across it, found by search on the solved response, flatten the reading to 8×10⁻⁵ per cent across six decades.
-
The rail that is an input error
The best burden voltage across a shunt is the geometric mean of the amplifier's offset and the supply, and moving the shunt to the high side does not change that form — it changes what the offset is. A hundred-decibel amplifier on a twelve-volt rail turns the rail into 120 µV of equivalent input error, twenty-four times its own five, so the optimum moves from 7.75 mV and 0.129 per cent to 38.73 mV and 0.644. The two are equal only at 128 dB, and with the common-mode term removed the optimum returns to the low-side value exactly.
-
The resistance that depends on the reading
Three of a shunt's errors are free of the current being measured, which is the whole content of the burden-voltage optimum. The fourth is not: the shunt dissipates, warms, and its resistance rises — so the divisor the reading uses is a function of the reading. Solved as a fixed point it agrees with R₀/(1 − αθI²R₀) to 2×10⁻¹⁶, and along the optimum, where the dissipation is I·u* rather than I²R, the error is the FIRST power of the current: 7.75 ppm at an ampere, 775 at a hundred, fitted exponent 1.0007.
-
The pulse that ends before the heat
A shunt's self-heating error is a fixed point in the steady state — 775 ppm at 100 A for the shunt the burden optimum picks, through 20 K/W. A pulse never reaches it. Heat leaves the element through a ladder network — the element's own 5 mJ/K, its terminations, the board — and a pulse short against the element's millisecond heats it adiabatically, by P·t over its heat capacity alone: 0.737 ppm for 100 µs at 100 A, a thousandth of the held figure, 10.7 ppm for 10 ms. Along the burden optimum the error is linear in the current, so the current a pulse may carry for 100 ppm is exact: 12.9 A held, 936 A for 10 ms, 13.6 kA for 100 µs. A reading averaged over the pulse carries half the error of one taken at its end while the heating is adiabatic, and the section-by-section thermal model a data sheet quotes is 10% wrong at 7 ms.