Emitter degeneration — the series
-
What a resistor in the emitter buys
Degeneration is described as a trade: give up gain, get linearity. Measured on the transfer curve, the two sides of that trade are not the same size. Dividing the gain by six moves the amplitude at which distortion reaches one per cent by thirty-five times — the square of the factor — and the amplitude at which the gain is one per cent out by only twelve. So the two edges close up, and a well-degenerated stage stops being limited by its linearity and starts being limited by how accurately its gain is known.
-
Where the two exponents come from
What a resistor in the emitter buys measured two exponents and could explain neither: the distortion edge moves as the square of the degeneration factor and the gain edge as its 0.950 power, and at a factor of exactly three halves the gain error vanished. The degenerated transfer curve has no closed form forwards and an exact one backwards, and reverting that series gives all three. The distortion exponent is exactly two; the gain edge is proportional to D squared over the root of the absolute value of three minus twice D, which is infinite at three halves and tends to a three-halves power; and the two edges are 7.07 apart on the bare device and 1.62 at a factor of eleven, against 7.06 and 1.61 measured.
-
What the fourth order says about the third
A closed form derived by neglecting the fourth-order term is a claim with an error, and the error is a quantity the fourth-order term can be asked about. Carried one order further, the degenerated exponential's reversion predicts 7.33 per cent where the leading expression was measured to be 6.89 per cent optimistic — and takes the residue to 0.362 per cent. The correction has its own edge, in the same quantity, and it is measured too.
-
The order that stops helping
Three essays in this field have derived expressions for the amplitude at which a degenerated stage's distortion reaches a target, each one order longer than the last, and each one nearer the measurement. This is where that stops. The error of an expression truncated at order m grows as the m-th power of the drive — 2.00, 4.00 and 5.88 measured — so every added order buys a range that ends sooner than the last one bought, and above 8.9 thermal voltages the six-term expression is further from the device than the four-term one.