Two windings, and the band between them
The band a turns ratio holds over
Every model this collection has drawn is right below a number or above one. A transformer is the first that is wrong at both ends and right in the middle, and the flat part is not the turns ratio either — measured on the solve it is the turns ratio times the coupling, times what the two winding resistances leave of the whole loop — and the first version of that last factor was a coincidence that held for every coupling and broke at a different load.
What coupling buys, and where it does not
Winding a transformer better is winding it more tightly coupled, and the coupling coefficient is the number a maker works on. Measured across six designs from k = 0.8 to k = 0.999, it moves the upper band edge by 168 times and the lower one by 1.083 — so every hour spent on the winding buys bandwidth at one end of the band and, to within eight per cent, nothing at all at the other.
Which picture sets the upper edge
Every account of a transformer's high-frequency limit names the same mechanism: the leakage inductance resonating with the winding capacitance. At fifty ohms that resonance is at 1.13 MHz and the measured edge is at 81.3 kHz — a factor of fourteen away — because what actually binds is the leakage in series with the load, a first-order corner with no resonance in it at all. The two swap at about 1500 Ω, and both accounts are current because both are sometimes right.
Where the band goes entirely
The three essays before this one measure a transformer's band, and all three assume there is one. Past a few hundred ohms of load there is not: the leakage that sets the upper edge is also what damps the resonance behind it, and a lightly loaded, well-coupled transformer peaks at 3.03 times its own turns ratio. A passive component with voltage gain is not a transformer behaving badly. It is a resonant circuit, and asking for its band returns the skirts of a resonance.
One number from two measurements
Neither of this site's two standing checks can see a mutual inductance. A coupling adds no current anywhere, so Kirchhoff's law is unmoved by it; a coupled pair dissipates nothing, so the energy balance is unmoved too. A coupling stamped into the wrong row would produce a well-formed solution to a different circuit and both checks would pass — so the field needed a third route, and the one it uses is the bench method: connect the windings in series one way, then the other, and the difference is four times the mutual inductance.
Two ports from two one-ports
An inductor is a one-port: one impedance, one number. Two of them coupled is a two-port, and the four impedance parameters that describe it are recovered here by four solves — each port driven with the other open, the definition read literally. Two of the four come out equal to 2.8 × 10⁻¹⁶, which is reciprocity, and is the first property a coupling stamped into one row instead of two would break.
The energy is in the gap
A ferrite core is chosen for its permeability and then deliberately cut, and the cut is not a compromise. Reluctance adds in series, so a two-hundred-micron gap in a µᵣ = 2000 core holds 87.0% of the stored energy while the ferrite holds thirteen — and the share is lg/(lg + le/µᵣ), a ratio of two lengths, containing neither the turns nor the area. The material chosen for its permeability holds almost none of what the component stores.
A boundary in volt-seconds
A core saturates on the integral of the voltage applied to it, not on the current through it and not at a frequency. The quantity that belongs to the core is N·Ae·Bsat — 3.500 mWb-turn here — and it has no frequency in it at all. Everything a data sheet says about a transformer's frequency rating is that one number divided by 2πf once: measured on a marched flux, the voltage a winding may carry is proportional to frequency to a fitted exponent of 1.000000.
The flux that walks
The previous essay's saturation limit is an amplitude, and an amplitude can be respected. This one cannot. A drive whose two half-cycles differ in volt-seconds by one per cent adds the same small area to the flux every cycle, so it reaches saturation after 64 cycles — and halving the drive gives 128, and a tenth of it gives 637. Reducing the amplitude buys time in exact proportion and removes nothing. There is no amplitude at which the design is inside a limit.
The resistance that grows with frequency
The rule of thumb names the frequency at which the skin depth equals the conductor's radius as the point where the effect begins. Computed exactly from the Kelvin functions, the resistance is already 2.05% up there — and the rule's own asymptote says 1.0000, no effect at all. Two decades higher the two agree to 0.01%, which is what makes it an asymptote rather than a formula, and what makes the frequency it names the wrong one to design at.
The inductor that is a capacitor
The frequency field's second essay measures where a capacitor stops being one, because its own leads are an inductance. This is the same measurement with the components exchanged, and it comes out with the same structure and a different number: the ten-per-cent departure from ωL sits at f₀/3.317, and it sits at f₀/3.317 at every winding capacitance and every inductance tried. The shape of the departure belongs to the resonance rather than to either part.
The copper that makes it worse
The rung below measured one conductor pushing its own current to its rim, and there is nothing to optimise in it: thicker wire is always less resistance. Stack the conductors and the quantity changes character. Each layer sits in the field of the ones below it, the loss that field drives has no upper bound in the thickness, and the product turns over — so a portion of four layers has a best foil thickness, and above it more copper is more resistance. The best thickness is the fourth root of three over the square root of the layer count, in skin depths, and the penalty at it is four thirds for every layer count above one.
The inductance the current decides
The rung below bounded the flux and the boundary is exact: the volt-seconds decide the flux swing whatever the material does, and a cycle whose current ripple runs from 519 mA to 75 A has the same flux excursion to better than two per cent. What saturation breaks is the relationship between that flux and the current — so a ripple the design expression puts at 514 mA is 1,022 mA at 2.56 A of load, the peak reaches 3.57 A where the part is at a fifth of its nameplate inductance, and the same part has three saturation currents depending on which per cent it was quoted at.
The area a curve cannot have
Every magnetic model in this collection is a single-valued B(H), and a single-valued B(H) cannot dissipate: ∮H dB around a curve is zero, so the transformers and inductors here have all run cold. Giving the material a second branch costs one object — a play operator, which lags the field by a threshold and is otherwise nothing — and a superposition of twenty-four of them produces a loop with 12.481 joules per cubic metre in it, a coercivity of 8.958 amperes per metre and a remanence of 22.3 millitesla, none of which was handed in. At zero threshold the whole thing collapses onto the curve the field already had, to fifteen figures.
The exponent nobody put in
A catalogue prints core loss as a coefficient times the frequency raised to one power and the flux to another, and the two exponents look like material constants. Neither is. On a loop built from play operators the frequency exponent is exactly one — a theorem, not a fit, because a rate-independent locus has the same area however fast it is traced — and the flux exponent is a local slope that runs from 2.94 at half a millitesla to 1.46 near saturation, so five windows on one measured curve give β from 1.58 to 2.84 and predictions three times apart at a hundred and fifty millitesla.
The duty cycle that costs nothing
A converter drives its core with a rectangular voltage, so the flux is a triangle whose two slopes differ by nineteen to one at a five per cent duty. The play-operator core charges exactly the same for all of them — 2.1006 joules per cubic metre at every duty and for a sinusoid of the same peak, to three parts in ten thousand — because a rate-independent locus depends on where the flux went and not on how fast. Real cores charge tens of per cent more, and the standard correction hides its entire waveform dependence in α − 1, which is the one term a rate-independent model has none of.
Two inductances at one current
A data sheet prints one L(i) curve and there are two. An operator sitting inside its own backlash contributes nothing to dB/dH, so a small excitation sees only the operators still moving — every one at the tip of a loop, none just after a reversal — and the same core at zero bias measures 14.90 millihenries pushed downward and 8.30 pushed upward, a factor of 1.80. The same split decides what a converter's ripple costs: held at the flux swing volt-seconds actually fix, a twenty-millitesla ripple costs twelve times more at a hundred and seventy-five amperes per metre of bias than at none, and above a hundred and eighty-three the question has no answer at all.
The current inside the iron
Every core-loss law has an eddy term of the form d²f²B²/6ρ, and it is derived by assuming the flux is uniform across the lamination — an assumption that is a frequency and that the expression does not carry. Solved instead as a diffusion, the exponent is exactly 2 below the frequency at which the sheet is two skin depths thick, exactly 1.5 above it, and it undershoots to 1.485 on the way. For a 0.35 mm sheet the crossing is 465 hertz, so at a kilohertz the classical term is 1.74 times the truth and at ten kilohertz it is forty-seven times.
The core the solver has to remember
A saturating inductor's state is one number, because the current is a function of the flux linkage. A hysteretic core's is not: half an amp is one flux on the way up and a different flux on the way down, and there is no function of the current that returns the flux. So the march's state vector gains twenty-four more numbers, one per play operator, and the Newton loop is forbidden to touch them. The circuit and the bench then agree on the loss to three parts in ten million — one integral taken at two wires, the other inside the material.
The loss that depends on what it causes
Every thermal figure in this collection has had the power handed in. A ferrite's has no business being: its saturation flux falls with temperature, its permeability rises, and both move the loss. Closing that loop makes the temperature a fixed point rather than a product — and the fixed point has a stable root at 89 degrees whose loop gain is negative, an ignition root at 191 whose loop gain is 120, and a thermal resistance of 183 kelvin per watt at which the two touch and neither exists.
The distribution the bench cannot see
Six rungs of this ladder assumed a uniform density of operator thresholds, and the reason given was that a uniform density makes the small-signal law come out cubic. That reason is weaker than it looks: every density finite at the origin does the same. Matched on a measured coercivity, four distributions whose spreads differ by 2.5 times give the same remanence to 0.6 per cent, the same loop area to 1.0, and the same branch-slope ratio to 0.54 — and small-signal exponents from 2.81 to 3.81. The major loop cannot see the shape and the small signal cannot see anything else.
The assumption that is a geometry
Every alternating-resistance number this collection has computed for a winding rests on one sentence — the field is parallel to the layers everywhere — and the sentence has never been tested, because testing it needs a field. Solved as one, a portion of foils that fills its window returns Dowell's expression to 0.155 per cent; the same copper filling a quarter of it returns 9.00 against the expression's 16.38, and dissipates 0.528 watts a metre against 0.232. The ratio falls by 45 per cent and the loss more than doubles.
The turns nearest the gap
A gapped inductor's flux does not turn a corner into the iron on its way out of the gap; it bulges into the window and crosses the copper at right angles to the layers. Four tenths of a millimetre from a one-millimetre gap, the worst turn of an eight-turn winding dissipates 37.5 times its direct-current loss and the winding as a whole 14.1 times. Move the same winding three millimetres further out and those become 2.9 and 2.4 — and the distance that governs it is 0.60 millimetres, which is not the gap length and does not scale with it.
The wire that is not a foil
Almost no winding is made of foil, and the closed form for a winding's alternating-current resistance is about foils. The bridge between them is a substitution — squeeze the layer's conductors together, spread the result back across the breadth, divide the conductivity by the porosity — and it replaces a two-dimensional geometry with a one-dimensional one. Solved as a field it is exact where it must be, at a porosity of one, and 7.2 per cent high at a porosity of 0.40. It errs on the safe side, which is the half of the answer nobody could have assumed.
The gap that is bigger than it is
A magnetic circuit prices a gap as g/µ₀A and everybody knows that is low, because the flux bulges out of the sides. The usual repair — add one gap length to each dimension of the gap's area — supplies half the correction at a 0.3 mm gap and 85 per cent at 1.7 mm, on a correction worth 10 per cent of the inductance at the first and 33 at the second. It is not a rule that is right or wrong; it is a rule whose accuracy is a function of the very thing it is correcting.
The inductance that is a shape
Leakage inductance is the one transformer parameter that belongs to the geometry rather than to the material: twice the magnetic energy in the window under equal and opposite ampere-turns, divided by the square of the current. Solved as a field it is 3.086 microhenries a metre against a closed form's 3.128 when the copper fills the window, and 4.608 against 6.255 when it fills half of it. Interleaving is worth 3.11 times and not the four it is quoted as, and the missing 0.89 is the insulation nobody puts in the formula.
The boundary that is a starting point
A wound part with a stable operating point at 88.8 degrees and an ignition temperature at 191.1 will never reach the second, because nothing takes it there. Marched in time rather than solved for its steady states, the same equation says what does: a trajectory starting at 189.6 degrees settles back and one starting at 192.6 leaves the material's range in twelve seconds — two starts three kelvin apart. And an overload of four times the normal loss is survivable for ever, while seven times is survivable for seventeen minutes.
The optimum that does not move
A foil winding has a best thickness — past it, more copper is more resistance — and at that thickness the alternating-current resistance is four thirds of the direct-current resistance, whatever the layer count. Both of those are one-dimensional results, and this ladder has spent three rungs finding that the one-dimensional picture is 82 per cent wrong about the resistance ratio. Solved as a field, the optimum drifts by 8.3 per cent between a full window and a quarter-full one, and four thirds becomes 1.34, 1.35, 1.41. The trade barely moves while everything it is made of moves a great deal.
The gap that is three gaps
Reluctances in series add, so one gap of 1.2 millimetres and three of 0.4 are the same magnetic circuit: the same inductance, the same saturation current, the same energy in the air. They are not the same field. Solved in two dimensions, the winding beside the single gap dissipates 6.52 times its direct-current loss and its worst turn 13.3; beside three gaps those are 3.00 and 3.7. And there is a best number of gaps rather than a monotone gain — past three, spreading them along the leg brings each one close to a different part of the winding.
The other half of the same window
The two-dimensional solve that settled what a winding's alternating-current resistance really is computed one of the window's two parameters and never mentioned the other. Read with Laplace instead of the vector potential, the same cross-section returns 926.9 picofarads a metre — and 89 per cent of that energy sits inside films that occupy 14.1 per cent of the window. The instrument agrees with a layered slab to three parts in ten thousand billion and converges on a real winding at order 1.34, and the reason for the shortfall is not the arithmetic but the corner of a conductor.
Interleaving is a choice, not an improvement
Splitting a transformer's windings into six sections divides its leakage inductance by 21.4 and multiplies its winding-to-winding capacitance by 11.0. The product of the two — which is what sets the frequency the part stops being a transformer at — moves by 1.94, and the resonance it decides goes from 1.804 to 2.515 megahertz for all that work. What interleaving really changes is the winding's characteristic impedance, 95.2 ohms down to 6.2, and nobody quotes it.
The optimum a spectrum moves
The best foil thickness for a winding is derived for one sinusoid and quoted as a property of the geometry: a minimum at four thirds of the direct-current resistance, whatever the layer count. Weight the loss by the current in each harmonic instead and a square current of the same fundamental wants foil 1.728 times thinner and lands at 1.83, and a narrow pulse wants it 3.68 times thinner. Four thirds is a property of the current. The constant that replaces it for an ideal square edge is exactly two, and a real winding sits between them at a place its edge rate decides.
One dissipation, two exponents
The core this ladder built takes two numbers — a threshold spread and the fraction of the magnetisation that follows the field with no threshold — and seven rungs moved the first and left the second at 0.55 without ever saying why. The first decides how much loss there is: area, coercivity and remanence are all exactly proportional to it over four decades, at 0.625961 joules per cubic metre, 0.449775 and 1.130408 millitesla per ampere-metre of spread, the last two of which are closed forms. The second decides nothing about the loss at all — it is single-valued, so it contributes exactly zero to the loop area, to twelve digits — and it moves the Steinmetz exponent from 1.5042 to 2.9860.
The walk that stops
A drive whose two half-cycles differ in volt-seconds walks the flux to saturation in a count of cycles, and the rung that measured it concluded that no amplitude puts the design inside a limit. That model has a stiff source and a winding of no resistance. With resistance in the loop the walk has a fixed point, held by an identity the material is not in — the mean magnetising current is the drive's direct component divided by the resistance, to seven parts in 10¹³ — and the boundary becomes a resistance rather than a time: 0.1014 ohms bisected, at a one per cent imbalance and half the volt-second limit.