A 1% imbalance, and the 64 cycles it survives
Drawn above at its default parameters, which is almost never how an essay calls it. A placement states the numbers that essay is arguing about, so the figure a reader meets is about that argument rather than about the generator — 98% of the placements on this site pass one, and the phase that raised that number from 12% found eight captions describing a figure the page was not showing.
At those defaults the edge it states is 64 cycles, and halving the drive gives 128 — the right-hand slot
of the caption strip, which on this site is never used for anything else, and which is read
back out of the drawing above rather than out of the code that wrote it.
It belongs to Two windings, and the band between them, which is to say a change to it is a
change to lib/figures/magnetics.js.
It takes a slider on volt-second imbalance (%) with 5 settings,
and every one of them has passed the same assertions as the frame above — a figure whose
circuit stops doing what its caption says at any setting stops the build.
Called by 5 essays
which is the blast radius of changing it
A boundary in volt-seconds
A core saturates on the integral of the voltage applied to it, not on the current through it and not at a frequency. The quantity that belongs to the core is N·Ae·Bsat — 3.500 mWb-turn here — and it has no frequency in it at all. Everything a data sheet says about a transformer's frequency rating is that one number divided by 2πf once: measured on a marched flux, the voltage a winding may carry is proportional to frequency to a fitted exponent of 1.000000.
The flux that walks
The previous essay's saturation limit is an amplitude, and an amplitude can be respected. This one cannot. A drive whose two half-cycles differ in volt-seconds by one per cent adds the same small area to the flux every cycle, so it reaches saturation after 64 cycles — and halving the drive gives 128, and a tenth of it gives 637. Reducing the amplitude buys time in exact proportion and removes nothing. There is no amplitude at which the design is inside a limit.
The delay that is two delays
Modelling one comparator delay applied to both transitions makes the two half cycles equal by construction, and the fix is a change of one line. Made, the duty cycle moves by 0.28 per cent for twenty nanoseconds of skew rather than the 0.40 the obvious expression gives, more hysteresis improves the duty cycle and worsens the volt-seconds at the same time, and ten nanoseconds of skew saturates a hundred-turn core in 231 cycles.
The inductance the current decides
The rung below bounded the flux and the boundary is exact: the volt-seconds decide the flux swing whatever the material does, and a cycle whose current ripple runs from 519 mA to 75 A has the same flux excursion to better than two per cent. What saturation breaks is the relationship between that flux and the current — so a ripple the design expression puts at 514 mA is 1,022 mA at 2.56 A of load, the peak reaches 3.57 A where the part is at a fifth of its nameplate inductance, and the same part has three saturation currents depending on which per cent it was quoted at.
The walk that stops
A drive whose two half-cycles differ in volt-seconds walks the flux to saturation in a count of cycles, and the rung that measured it concluded that no amplitude puts the design inside a limit. That model has a stiff source and a winding of no resistance. With resistance in the loop the walk has a fixed point, held by an identity the material is not in — the mean magnetising current is the drive's direct component divided by the resistance, to seven parts in 10¹³ — and the boundary becomes a resistance rather than a time: 0.1014 ohms bisected, at a one per cent imbalance and half the volt-second limit.