Two meters, one current, and neither of them measuring the heat

computed by solving, not by drawing, at 35 conduction angles. The first curve is an average-responding meter: it rectifies, averages and multiplies by 1.1107, which is exactly right for a sinusoid — -7.8e-5% here — and exactly 11.07% high on a square wave, because the error is the ratio of two form factors and contains neither the amplitude nor the frequency. On a rectifier drawing its 100 W in sixty degrees of conduction it is -35.90% low. The second curve is a true-RMS meter that reaches 9 harmonics, which has no shape assumption in it and a bandwidth instead: it returns the root-sum-square of the lines it can see, and is one per cent low below every angle here of conduction. The crest factor at sixty degrees is 1.733, which is inside every instrument's rating — neither meter is failing because the peak is large. One is failing because the shape is not a sinusoid and the other because the spectrum is wider than it is.
Two meters, one current, and neither of them measuring the heatcomputed by solving, not by drawing, at 35 conduction angles. The first curve is an average-responding meter: it rectifies, averages and multiplies by 1.1107, which is exactly right for a sinusoid — -7.8e-5% here — and exactly 11.07% high on a square wave, because the error is the ratio of two form factors and contains neither the amplitude nor the frequency. On a rectifier drawing its 100 W in sixty degrees of conduction it is -35.90% low. The second curve is a true-RMS meter that reaches 9 harmonics, which has no shape assumption in it and a bandwidth instead: it returns the root-sum-square of the lines it can see, and is one per cent low below every angle here of conduction. The crest factor at sixty degrees is 1.733, which is inside every instrument's rating — neither meter is failing because the peak is large. One is failing because the shape is not a sinusoid and the other because the spectrum is wider than it is.-80-60-40-20050100150conduction angle (degrees)meter reading, per cent away from the truththe averaging metertrue RMS, 9 harmonicsthe constant1.1107on a sine-7.8e-5%on a square11.07%at 60° conduction-35.90%crest factor there1.733harmonics seen91% atnot on this sweepsolved, then checked — one current, two instrumentsneither is measuring the heating

Drawn above at its default parameters, which is almost never how an essay calls it. A placement states the numbers that essay is arguing about, so the figure a reader meets is about that argument rather than about the generator — 98% of the placements on this site pass one, and the phase that raised that number from 12% found eight captions describing a figure the page was not showing.

At those defaults the edge it states is neither is measuring the heating — the right-hand slot of the caption strip, which on this site is never used for anything else, and which is read back out of the drawing above rather than out of the code that wrote it. It belongs to Power, and the part that does no work, which is to say a change to it is a change to lib/figures/power.js. It takes a slider on harmonics the true-RMS meter reaches with 7 settings, and every one of them has passed the same assertions as the frame above — a figure whose circuit stops doing what its caption says at any setting stops the build.

Called by 5 essays

which is the blast radius of changing it

What a meter multiplies by

An average-responding meter rectifies, averages and multiplies by 1.1107, which makes it exactly right for a sinusoid and wrong for everything else by the ratio of two form factors — 11.07 per cent high on a square wave and 35.9 per cent low on a rectifier drawing its current in sixty degrees. It is also exactly right at one other waveform, a 145.90 degree conduction angle, which is nobody's sinusoid. Beside it a true-RMS meter that reaches nine harmonics is two per cent low on a square wave and never within one per cent of anything narrower.

Power, and the part that does no work

The current that sizes the transformer

A reservoir's crest factor is 13.374 at a thousand microfarads and the winding is not sized by it. The root-mean-square of the same marched current is 3.0069 times the load's direct current, so the copper dissipates 9.0417 times what it would carrying the direct current alone — and the two ratios diverge, from 3.04 apart at 220 microfarads to 5.95 apart at 4700. The expression for the mean output is wrong in three places whose signs differ, and at 313.9 microfarads they cancel to six microvolts while the ripple expression inside it is still 32.3 per cent high.

Circuits that do a job, and the range they do it over

The average a square root pulls low

A true-RMS converter squares, averages and takes the root, and the root of a quantity that ripples averages below the root of its mean. With a hundred-millisecond averager a sine is read one per cent low below 1.86 hertz, where the ripple is still ±20 per cent — and a second filter that steadies the display takes the ripple away and leaves the reading exactly as low as it was. A square wave is read exactly at any averaging time; a rectifier current conducting for twenty degrees needs 2.41 times the averaging a sine does. The implicit converter is the explicit one at half the time constant, and a reading falls 1.38 times slower than it rises.

Power, and the part that does no work

The noise a true-RMS meter reads low

A true-RMS converter reads a sine low by an amount that falls as the square of its frequency, and for anything but a slow sine that amount vanishes: 3.96 parts per million at ten times the averager's corner. Noise is not a sine. Its square fluctuates at every frequency down to zero, and the averager passes a share of that set by its own bandwidth against the noise's, so the reading is low by 1/(16Bτ) — the first power, not the second. Measured on seeded noise at Bτ = 10 it is 0.600 per cent low against a predicted 0.625; at 100, 672 parts per million. One reading scatters by eighteen times that, so no single reading shows the bias and the mean of a few hundred is nothing but bias.

Power, and the part that does no work

The cycle a converter has to know

Summing a waveform's square over a whole number of periods reads its root-mean-square exactly: no averager, no ripple, no bias. It needs the period, and a period known one per cent long puts a hundredth of a period too much into the window. Wherever that extra piece falls, the reading moves — on a sine by up to 0.50 per cent over one period, and by 0.46 per cent over ten, because the extra piece grows with the window as fast as the window does. The worst error is δ(CF² − 1)/2, set by the crest factor and the period error and not by how many periods are summed, until the excess reaches half a period. A square wave is read exactly from any window, and a 60° rectifier current twice as badly as a sine.

Power, and the part that does no work

Every generator