Input bias current — the series
-
The current the instrument draws
Every amplifier in this collection has had inputs that take no current, and that is not an idealisation of a small quantity — it is an idealisation of one whose size is decided by something outside the part. Fifty nanoamps is nothing until it flows in a megohm, and then it is fifty millivolts. The classical cure balances the two resistances and removes the bias current, leaving the offset current: worth a factor of ten, not a thousand, and it costs forty per cent of the noise density to get.
-
The cure that becomes a different circuit
The classical cure for an amplifier's input current is to make the two resistances its inputs look back into equal, and it reads as one instruction. Solved, it is two circuits meeting at 909 ohms — the feedback network's bottom resistor times (G−1)/G — and above that knee there is no resistor to add: the network is scaled to the source, which at a megohm means 11 megohms of feedback and at a gain of 1001 means 1001. Above the knee three different networks become one instrument to twelve figures, the noise penalty settles at 1.41420 against a √2 of 1.41421, and the benefit at 10.49 against two currents whose ratio is ten.