Winding capacitance — the series

2 essays on one idea, from the one that introduces it to the one that assumes the rest.
  1. The winding window solved electrostatically, in two portions. computed by solving, not by drawing. The same cross-section the loss solve reads, read with ∇·(ε∇φ) = 0 instead. Two things are the opposite way round from the magnetic problem and both are the whole difference. The iron is now a Dirichlet boundary rather than a Neumann one — an earthed core is an equipotential, so the field meets it at right angles instead of running along it — and a conductor carries a prescribed potential rather than a prescribed current. The thin curves are equipotentials, which are contours of φ, so equal spacing is equal potential step and crowded curves are a strong field. The copper is shaded by the potential each foil sits at, which rises along the winding rather than being one number. Winding to winding this window is 926.9 picofarads a metre, and 89 per cent of the energy is inside insulation that occupies a fraction of the window.

    The other half of the same window

    The two-dimensional solve that settled what a winding's alternating-current resistance really is computed one of the window's two parameters and never mentioned the other. Read with Laplace instead of the vector potential, the same cross-section returns 926.9 picofarads a metre — and 89 per cent of that energy sits inside films that occupy 14.1 per cent of the window. The instrument agrees with a layered slab to three parts in ten thousand billion and converges on a real winding at order 1.34, and the reason for the shortfall is not the arithmetic but the corner of a conductor.

    part 1 · magnetics
  2. The trade, in the plane where both halves of it live. computed by solving, not by drawing. Leakage inductance across, interwinding capacitance up, both solved on the same cross-section with the same cells. The faint diagonals are lines of constant leakage-times-capacitance, so a design action that runs along one of them has bought nothing and only moved where the energy is kept. Interleaving runs at slope -0.78, which is nearly along them: six sections cut the leakage 21.3 fold and multiply the capacitance 11.0 fold, and the product moves by 1.94. What it does change is the winding's characteristic impedance, 95 ohms down to 6.2 — a factor of 15. Thickening the interlayer instead runs at -4.8, steeply across the diagonals, and moves the product 5.2 fold over the same sweep. It is the cheaper action by that measure and it is not free either: the millimetre it spends is a millimetre of window that is not copper.

    Interleaving is a choice, not an improvement

    Splitting a transformer's windings into six sections divides its leakage inductance by 21.4 and multiplies its winding-to-winding capacitance by 11.0. The product of the two — which is what sets the frequency the part stops being a transformer at — moves by 1.94, and the resonance it decides goes from 1.804 to 2.515 megahertz for all that work. What interleaving really changes is the winding's characteristic impedance, 95.2 ohms down to 6.2, and nobody quotes it.

    part 2 · magnetics