Signal-to-noise ratio — where it appears
Named by 11 essays across 4 fields — each of them below, with the objects they name alongside it.
A floor and a ceiling
Every other boundary these essays measure is a ceiling. This one puts a floor underneath and measures the distance between them — 4.00 nanovolts per root hertz at the bottom, one per cent of harmonic distortion at 1.03 millivolts at the top, and 66.3 decibels of range in a ten-kilohertz measurement. Both ends are computed, neither is on a datasheet, and the arrangement of the stages decides which one moves.
The probe that takes a tenth
A ten-to-one probe buys an order of bandwidth for a tenth of the signal, and on a two-kilohm source the bandwidth is exact: 6.79 kHz becomes 69.2 kHz. The tenth of the signal is not a tenth of the signal-to-noise ratio. Solved resistor by resistor, the noise referred to the tip goes from 1.782 µV to 55.78 µV — a factor of 31.3 — because the divider that does the attenuating is nine megohms and a megohm, and √(n(n−1)kT/C) on the cable's own capacitance has no source resistance in it at all.
The factor the expression leaves out
The classical compensation for a photodiode amplifier is quoted both as the forty-five degree choice and as the maximally flat one, and it is neither: it leaves 1.18 dB of peaking and 52.4° of margin. Flat is at exactly √2 times it — fitted at 1.4186 against 1.4142, at every detector from 3 pF to 1 nF. And the third quantity the capacitor is supposed to trade, the noise, does not move at all inside the signal band: three compensations spanning a factor of fourteen give 8.37 against 8.36 µV in a 4.36 kHz measurement and 230 against 65 µV over the whole plane.
Flatness, and the two currencies it is bought in
The hold's droop takes the signal and everything arriving with it down together, so it costs no signal-to-noise ratio at all — a fact that is never stated and settles what correcting it can possibly be worth. Corrected digitally the price is headroom and is exactly the disease: 2.42 dB of flatness for 2.42 dB of output level. Corrected by an analogue shelf the price is image rejection and is nearly a constant: between 3.4 and 4.7 decibels whatever the band, so it is eight times the droop at a fifth of the clock and nine tenths of it at forty-nine hundredths.
The error a bigger resistor cannot help
Every other quantity in a photodiode amplifier improves with a larger feedback resistor: the signal grows as R and the resistor's own noise as √R, so the ratio goes as √R. The bias current does not behave like either — it flows in the same resistor the signal does, so its contribution is the ratio of the two currents with the resistance cancelled, 0.1 per cent at 25 °C and the same 0.1 per cent at a megohm and at a gigohm. The offset behaves the other way, growing as one plus the resistor over the diode's own leakage, and at 85 °C the two are 6.40 and 0.74 per cent against 0.10 and 0.11 at room temperature.
The tee that charges for its own compensation
A feedback tee makes a large transimpedance out of small resistors, and R₁(1 + R₂/R₃) + R₂ is the whole of what is usually said about it. The expression has no term for the noise gain, and the tap sets that to 1 + R₁/R₃ — nine, where a single feedback resistor of any value gives exactly one, because at direct current the source is a capacitor. One quantity then does everything: the signal and R₁'s own noise are multiplied together so the tee buys no signal-to-noise ratio at all, and the phase margin RISES from 1.8° to 15.9°.
The frequency a band moves at
The jitter rule is written for a sinusoid: ten picoseconds holds a tone at 1 MHz to 84.04 dB. A signal that fills the band up to 1 MHz holds 88.64 dB against the same clock, because each sample's error is its own slope times its own timing error, and a band's slope is set by its rms frequency — the top frequency over √3 for a flat band, 4.77 dB better. Pink content up to 1 MHz is 11 dB better than the rule and content falling as 1/f² is 29 dB better. So the same ten picoseconds hold sixteen bits to 199 kHz for a tone, 344 kHz for a flat band and 734 kHz for a pink one: an aperture figure needs a signal as well as a frequency.
A jitter that grows with the look
Two clocks with the same 0.1 ps spread in every period sample the same 10 MHz tone. If each edge is displaced independently, the error is 107.0 dB down at any record length. If each edge is displaced from where the last one landed — a free-running oscillator — the edges walk, and the error after fitting the best delay and frequency is 92.6 dB down over 256 samples, 80.3 over 4,096 and 68.2 over 65,536: ten decibels a decade of record, as the period spread times √(n/15). The one oscillator honestly has jitter figures from 0.10 to 4.7 ps depending on the length named. A locking loop is what gives the jitter a value: with a time constant of a hundred periods it stops growing at 87.0 dB.
The loop a reference allows
A sampling clock is a free-running oscillator held by a loop to a reference, and the reference has an error of its own. With 0.1 ps of period spread in the oscillator and 2 ps of white error in the reference, a first-order loop of 20 periods leaves the clock 0.453 ps from ideal — 90.9 dB on a 10 MHz tone — and that is the best any first-order loop can do: the oscillator's share rises as the square root of the loop's time constant, the reference's falls as one over it, and they are equal at σᵣ/σₒ. The clock's error there is the geometric mean of the two, so a reference a hundred times worse costs ten. On a spectrum the rule reads as one instruction: put the loop's corner where the free oscillator's skirt meets the reference's floor. And it holds only for long captures. Below about seven loop time constants the free oscillator beats every loop.
A frequency that wanders
Below its flicker corner an oscillator's phase noise falls thirty decibels a decade instead of twenty, because the oscillator's frequency itself wanders. A clock with 0.1 ps of period spread and a 100 kHz corner samples a 10 MHz tone at 84.1 dB over 1,024 samples and 52.9 over 65,536 — 14.7 dB worse than the walk alone — because past 2,277 samples its error grows as the capture rather than its square root. That crossing is 1.42 periods of the corner frequency for every corner. Fitting a parabola as well as a line buys 3.88 dB at every length and changes no slope; each further term buys a fixed fraction. And a first-order locking loop cannot stop it: the locked clock's variance grows with the logarithm of the record, 1.92 dB lost between 4,096 and 262,144 samples, until a loop with an integrator holds it at 87.5.
One step of dither per moment
A whole step of uniform dither makes a quantiser's error average to zero wherever the input sits, and leaves its power at x(1 − x) steps²: zero at a code and a quarter between codes, so the noise rises and falls with the signal. Two steps — a triangular dither — hold the power at a quarter everywhere and leave the third moment swinging by 0.096 steps³; three steps fix that too. Each added step fixes one more moment of the error and costs a twelfth of a step² of power: 3.01 dB for one, 4.77 for two. Subtracted after the converter, one step fixes the error's whole distribution for 0.00 dB.