Device mismatch — where it appears
Named by 15 essays across 7 fields — each of them below, with the objects they name alongside it.
The tolerance that can only take away
At a doubly terminated ladder filter's ripple peak the first derivative of the magnitude with respect to every reactance is zero to ten digits, which an earlier essay measured and which says nothing about how much the response moves. This says how: every second derivative is negative, so of six hundred ladder filters built from one per cent components not one is above nominal, the mean has shifted rather than the spread having grown, and doubling the tolerance quadruples the damage instead of doubling it.
Two loops, and the mismatch between them
Single loops of second, third and fourth order, marched alone, each stop working above an amplitude that falls with the order — which is why nobody builds a fourth-order single loop. The standard answer is two first-order loops with the first one's error fed to the second and differentiated back out, giving second-order shaping out of parts that cannot be unstable. The cancellation is between an analogue path and a digital one, and it is worth 25 decibels until the two differ by five per cent.
The error that is a distribution
The rung below solved a mirror and separated two errors — one that falls with beta and one that does not. Neither is what limits a real mirror. Two transistors on the same die differ, a fractional difference in saturation current is a fractional difference in collector current with nothing dividing it, and the honest object is a spread rather than a number: mean 3.84 per cent, standard deviation 1.96, worst of three hundred 8.43. Degeneration divides it by one plus gm·R and stops at the resistors' own tolerance, and where it stops is a voltage — a hundred millivolts, containing nothing but the ratio of two tolerances.
The offset that knows the signal
The charge a switch leaves on the capacitor it was sampling is the gate oxide capacitance times the channel area times the overdrive, and both terms in that overdrive depend on the input — one directly and one through the body effect. So the 5.67 mV a data sheet would call an offset moves by 1.86 mV across a volt of signal, which is a gain error of 0.186 per cent and only 3.4 µV of anything else. Opening the summing-node switch first divides the gain error by the amplifier's own gain, exactly, and what is left goes from twenty-nine times the sampled-noise floor to nineteen times below it.
One voltage added to two readings
A difference amplifier across a shared return rejects somebody else's current by 54 decibels, and the number is four resistors rather than the amplifier. Two sensors referenced to the same node do better by a different mechanism entirely: the interfering voltage is one voltage on one node, so it is added to both readings identically and the difference between them has none of it — 511 microvolts in each reading against two and a half picovolts in the difference, which is 166 decibels and is exact rather than good. What is left is not a tolerance but a mismatch between the two sensors' own return paths, ten nanovolts per per cent of it.
The mismatch that cancels itself
A current mirror's copy error is spread by three things the two transistors can differ in, and the population that measures it has always drawn all three at once. Turned on one at a time, a two per cent spread of saturation currents gives 1.910 per cent of copy error and a two per cent spread of current gains gives 0.00022 — because the gains enter only as a sum of reciprocals, which has no first derivative where they are equal. Then the standard cure un-cancels it, by a factor of 86.
The carrier a cable allows
A carrier-frequency amplifier removes an instrument's offset drift by exciting the bridge with alternating current, and the cable that was a resistance at direct current becomes a capacitance. Both output terminals see the same arms and the same capacitance, so the lag cancels in the difference: ten metres matched leaves 0.15 degrees at a hundred kilohertz where each terminal has 6.3. What does not cancel is the mismatch between the two conductors, arriving multiplied by the ratio of the excitation to the signal — two thousand at a thousand microstrain — so one per cent of it takes the allowed carrier from 205 kilohertz to 1.8.
The capacitance that is already a difference
A screened pair has capacitance from each conductor to the screen, which cancels in a bridge's difference when the two match, and capacitance between the conductors, which is a difference from the start and cannot cancel. Ten metres of it between a 350 Ω quarter bridge and its carrier amplifier allows 18.2 kHz for a 200 ppm loss, against 205 kHz for the screen alone. The two phases are ωR·ΔC/δ and ωR·C, the same slope with one divided by the signal, so a screen mismatch of δ·Cp/Cs on the gauge's own terminal cancels the pair's lag exactly: 0.10% at 1000 µε takes the limit to 143 kHz. That is what a carrier amplifier's capacitance balance finds when it nulls the quadrature — and because the mismatch's phase changes sign with the strain and the pair's does not, the balance holds in tension above half the strain it was set at and never in compression.
The rejection two capacitors lose at their corner
AC-couple both inputs of a differential instrument and the two coupling networks become part of its common-mode path. Two 1 µF capacitors one per cent apart turn common mode into difference at exactly half their mismatch at their shared corner — 46.0 dB of rejection at 0.159 Hz, from a pair that is perfect at direct current and far above. Behind a 90 dB amplifier they decide the instrument's rejection over five decades around that corner. A 10 V common-mode step arrives as a 36.8 mV differential pulse one time constant later. Four hundred pairs of 20 per cent electrolytics reject a median 25 dB. Coupling the difference instead of each side removes the dip and hands the common mode to the amplifier.
What a calibration at the carrier removes
The phase a cable puts on a carrier-excited bridge is a loss of 1 − cos φ, and a loss that is the same at every strain is a gain error — which a shunt calibration at the operating carrier exists to remove. Calibrated there, a synchronous reading of a quarter bridge through ten metres of matched screened pair allows 121 kHz for 200 ppm over ±2000 µε, where the phase measure allowed 16.5; the capacitance between the conductors, which no matching could improve, stops mattering. Where the reference is taken — at the instrument or from sense wires at the bridge — moves that by 1.2 per cent. What calibration cannot touch is a screen mismatch: its leak is a fixed voltage, not a fixed gain, and a hundredth of a per cent of it takes 121 kHz back to 11.5.
The sensor that is the capacitance
Read a capacitive displacement sensor through the same kind of cable that limited a strain-gauge bridge's carrier, and the roles exchange. On the bridge, a 1% mismatch in the cable's capacitance was a quadrature leak that grew as the square of the carrier and could be escaped by a lower one. On a sensor of two 10 pF plates it is 3.0% of full-scale displacement, in phase, at every carrier from 100 Hz to 1 MHz — because a capacitance between an excitation conductor and the sense conductor is in parallel with the measurand and is a sensor capacitance. No detector phase separates it and no carrier escapes it; only geometry does. Screen each conductor separately and there is nothing left to mismatch.
Two decibels of matching for one of gain
An offset gives a differential pair back the second harmonic its symmetry removed. Put resistors in the emitters and that second harmonic falls as the cube of one plus gₘRₑ at a fixed input and as its square at a fixed output — measured slopes of −3.00 and −2.00 — so each decibel of gain given up buys two decibels of distortion, or two decibels more offset at the same distortion. A matching specification that allowed 0.535 mV for −60 dB at 10 mV of output allows 2.14 mV at gₘRₑ = 1. The worst case over all drives relaxes more slowly: the offset below which the second harmonic can never reach one per cent goes from 1.36 mV to 4.39 mV as gₘRₑ goes to three, because the peak it limits sits where the pair saturates, and degeneration only moves that further out.
The cure that needs one current
Balancing the resistances an amplifier's inputs look into removes whatever its two input currents have in common and leaves their difference. On a plain bipolar input the two are one current at two pins, correlated at 0.991, and the cure is worth ten. On an input whose bias current has been cancelled they are two residues of either sign, correlated at 0.10, and over 400 seeded parts the cure makes the error 38 per cent worse. It is worth 1/√(2(1 − ρ)) for a zero-mean current, nothing at ρ = ½, and in general exactly the input current over the offset current.
The levels the loop cannot shape
Give a second-order noise-shaping loop a quantiser of several bits instead of one and every bit beyond the second buys six or seven decibels, the best input amplitude climbs from 0.6 of full scale to 0.95, and loops of third and fourth order that will not run on one bit run on three or four. What it charges is outside the loop's reach. The levels the quantiser feeds back enter where the input does, so their errors are passed rather than shaped: a three-bit loop loses its lead over a one-bit one when each level is out by 0.027 per cent, its error stops falling with oversampling, and the error arrives as harmonics. One bit is immune because two levels always lie on a line.
The resistor mismatch that is only an offset
Two emitter resistors that differ by δ unbalance a degenerated pair, and with an ideal tail they do it in the simplest way possible: the arm currents always sum to the tail, so the mismatch adds the constant (Iₜ/2)·R·δ = Vₜ·gₘRₑ·δ to the input and nothing else. Solved arm by arm, a 1% mismatch at gₘRₑ = 3 is the balanced pair moved by 0.776 mV to 4 × 10⁻¹⁶ of the tail, and a trim of that size leaves no second harmonic at any drive. What separates it from a junction's offset is that it grows with the degeneration meant to divide it: at a fixed output its second harmonic falls as gₘRₑ/(1 + gₘRₑ)², one decibel per decibel of gain rather than two, and it takes over from 0.5 mV of base–emitter mismatch at gₘRₑ = 1.93. For −80 dB at 10 mV of output the resistors must match to 0.823% at gₘRₑ = 1 even with perfect transistors.
Named alongside it
The objects these essays reach for when they reach for this one.
Measurement errorCommon-mode rejectionComponent toleranceDesign tradeoffEmitter degenerationParasiticsDifferential pairExcitationModel rangeOffset voltageStrain gaugeWheatstone bridge