Concept

Insertion loss — where it appears

The power a component costs the path it is inserted into, measured as the ratio of what arrives with it to what arrived without it. It is one of the two numbers a matching network is judged on, and the other is the band over which it holds.

Named by 13 essays across 5 fields — each of them below, with the objects they name alongside it.

A 4.0:1 load reads 1.13:1 through twenty metres of cable. computed by solving, not by drawing. A 200 Ω load on a 50 Ω line — a standing-wave ratio of 4.00 at the load itself — measured from the other end of a length of cable that attenuates 0.500 dB per metre at 1 GHz. The reading falls as the length grows, exactly as |Γ| times ten to the minus twice the one-way loss over twenty, and reaches 1.5 at 9.5 m and 1.128 at twenty metres, which is 24.4 dB of return loss and would pass any acceptance test. The load is unchanged; the instrument is looking at it through 10.0 dB of attenuator. The length that hides it falls 3.16× per decade of frequency, which is the root of ten and is the attenuation's own law.

The mismatch that the cable hides

A lossless line carries a reflection back unchanged, so the standing-wave ratio at the instrument is the standing-wave ratio at the load. A real line does not, and the departure is exact: ten decibels of one-way loss improves any mismatch by twenty. A four-to-one load at the end of twenty metres of ordinary coaxial cable measures 1.13 at the near end, a return loss of 24 decibels, and passes an acceptance test the load could never pass. The boundary is a loss rather than a length, which makes it a frequency: 30.2 metres at 100 megahertz, 9.5 at a gigahertz, 3.0 at ten.

lines · Line loss
An order-5 ladder driven from 2× the 1 kΩ it was designed between. computed by solving, not by drawing. A doubly-terminated Butterworth ladder is a two-port designed between two stated resistances, and the resistances are part of the design rather than the environment it happens to be used in. At match it loses 6.021 dB — exactly half the voltage — and its passband has no peak anywhere in it. Driving the same five reactances from 2× that resistance moves the shape by 2.345 dB and the insertion loss to 9.542 dB. The band inside which the shape is right to 0.5 dB runs 0.8857× to 1.1371× — a window of 25 per cent on a quantity usually written down as a round number. And the two sides are not alike: at twenty times the design resistance the departure has settled at 5.33 dB, while at a twentieth of it the passband is 15.51 dB out with 7.21 dB of peaking on it, so driving a ladder from too low an impedance is worse than driving it from too high a one.

The two resistors a ladder was designed between

A passive ladder filter is not a transfer function with some resistors attached; it is a two-port designed between two stated resistances, and the resistances are as much part of the design as the inductors. Driving an order-five Butterworth from anything outside 0.886 to 1.137 times its design resistance puts more than half a decibel of error on the passband — a tolerance tighter than the resistor is usually specified to — and the two sides of that window are not alike.

filters · Filter termination
The same three stages, in two orders. computed by solving, not by drawing by Friis's cascade. With the low-noise amplifier first the chain's noise figure is 3.31 dB; with the mixer first it is 12.01 dB. The gain is identical either way — 48.0 dB — so the 8.70 dB is bought with nothing but an ordering. Everything after the first stage contributes 26.0% of the total. The 2.0 dB of cable in front has gain below one, so it multiplies every later stage's contribution rather than dividing it.

The loss in front, counted twice

A decibel of cable before an amplifier costs a decibel of signal, which everybody expects, and a decibel of noise figure, which is a separate decibel arriving from a separate place. Measured across the slider it is exact: 1.31 dB of chain noise figure becomes 2.31 with one decibel of cable and 9.31 with eight, every time, while the 8.70 dB that stage ordering is worth does not move at all. A lossless reactive network in the same position costs nothing, because only the real part of an impedance is warm.

noise · Johnson noise
Twenty metres buys 20 dB of apparent match and costs 10 dB of noise figure. computed by solving, not by drawing. The same cable and the same 200 Ω load as the reading, with the amplifier that is actually behind the instrument. The rising trace is the return loss the instrument reads, which is the load's own 4.44 dB plus twice the one-way loss. The lower pair is the chain's noise figure: a 2 dB amplifier with the cable in front of it, counted as a matched attenuator whose noise factor is its loss, and counted honestly from the available gain of a lossy line driven by a source that reflects 0.60. The first says the exchange rate is exactly two decibels of match per decibel of noise figure, at every length here. The second is higher everywhere — by (1−Γ²u²)/(1−Γ²), which is 0.028 dB at five centimetres and 1.938 dB, the load's own mismatch loss, once the cable is long enough to have absorbed the reflection. At twenty metres the instrument reads 24.4 dB and the chain costs 13.92 dB against the amplifier's own 2.

The cable that hides two things

A length of cable improves a return-loss reading by twice its loss and raises a noise figure by once it, so the rule of thumb is two decibels of apparent match per decibel of floor. Both halves are owned here and neither essay had the other. Put together they say what an acceptance limit costs: making a 4.0:1 load read 1.50:1 spends 6.53 decibels of noise figure, against a mismatch that was itself costing 1.938 — and the exchange rate is not two but 2(1−Γ²)/(1+Γ²), which is 0.94 where a pad is actually short.

lines · Line loss
A core loss of 100 kΩ gives the resonance a floor at −66 dB, and by 10.0 GHz the choke is worth 0.02 dB. computed by solving, not by drawing. The common mode at the load, in decibels against the same circuit with no choke in it, with 5 pF across each winding and a core loss of 100 kΩ across each, drawn over the lossless curve. At the winding's resonance, 1.59 MHz, the inductance and the capacitance cancel and what is left is the loss, so the deepest point is 66.02 dB — 20·log(1 + (Rp/2)/(Zs + Zl)), with no inductance and no capacitance in it. Above the resonance the part is a capacitor across the path it was fitted to block, and by 10.0 GHz it attenuates 0.02 dB.

The depth a resonance does not have

The inductor one mode cannot see printed its choke's best attenuation as 102 decibels at 1.59 megahertz. Swept with 1,999, 2,000 and 2,001 samples the same lossless part reports 110.0, 96.3 and 103.6 decibels, because a resonance with nothing to dissipate has no bottom and a sweep reports how near its nearest sample fell. Give each winding a core loss and the depth is 20·log(1 + (Rp/2)/(Zs + Zl)) — 66.02 decibels at a hundred kilohms, twenty more per decade of loss, with no inductance and no capacitance in it, and half of it belonging to the circuit the choke sits in.

lines · Common-mode choke
What an L-section costs when its parts have a quality factor of 100. computed by solving, not by drawing. The same L-section as the ideal one, with each component given a series resistance of its own reactance over 100, and the efficiency read off a solve rather than from an expression. The section circulates Qₛ times the load's current through its own parts, and Qₛ is √(ratio − 1) with nothing left to choose, so the loss is TWICE Qₛ/100 — once in the inductor and once in the capacitor — to 4.40% wherever it is small. The consequence is that a match starts to cost something at a ratio nobody would call demanding: one per cent at a ratio of 1.253 — which is fifty ohms to 62.7, and is 1 + (Q/200)² to 0.25%. Splitting the match buys efficiency only above a ratio of 10.0: at a ratio of three one section loses 2.76% against 3.35% in two, and at a hundred 16.6% against 11.2%. The best number of sections for efficiency is 2 at a ratio of twenty and 4 at a ratio of a thousand — which is not the answer the band gives, where the band keeps improving with every section.

The efficiency a fixed Q costs

An L-section's quality factor is √(ratio − 1) with nothing left to choose, and the same fixed Q that decides its band decides what it dissipates. The circulating current is Q times the load's and it goes through both components, so the loss is twice Qₛ over the components' own Q — measured to 0.03 per cent. With parts of Q 100 that is one per cent at a resistance ratio of 1.253, which is fifty ohms to sixty-three. And splitting the match buys efficiency only above a ratio of 10.02: below it a second section adds two more lossy parts for less than it takes off anybody's Q.

frequency · Series-parallel
A 0.5 dB Chebyshev ladder of order five passes what it does not reflect: the two powers sum to one to 2e-15. computed by solving, not by drawing: a fifth-order Chebyshev ladder of 0.5 dB ripple between 1 kΩ terminations, solved at 481 frequencies. The transmitted power is the transducer gain, read from the load voltage; the reflected power is |ρ|², read from the impedance the filter presents to its source. Their sum is one to 2.0e-15 everywhere. The reflection reaches 0.1087 at each ripple trough, against ε²/(1 + ε²) = 0.1087 with ε² = 10 to the power ripple/10, less one, a return loss of 9.64 dB, and falls to zero at direct current and at 0.555 and 0.898 of the corner, where the transmission is at its maxima. The ripple band ends at 0.944 of the corner. The slider is the ripple.

What a filter does not pass, it sends back

A passive LC ladder built from lossless reactances has nowhere to put power except the load and the source. So the power it transmits and the power it reflects sum to what the source makes available — to 2 × 10⁻¹⁵ across a fifth-order Chebyshev, read from two different ports — and every passband specification is a return-loss specification in disguise: half a decibel of ripple is 9.64 dB of return loss at every order, a hundredth of a decibel is 26.4. The same identity predicts the filter's response from any source resistance out of one input impedance, and bounds the damage a wrong source can do by composing two reflections.

filters · Filter termination
With inductors of Q 100 the filter absorbs up to 10.5% of the available power, and the loss rate times its delay predicts the curve's shape — 11.2% at the same frequency. computed by solving, not by drawing. The fifth-order 0.5 dB Chebyshev ladder filter of the reflection essay, each inductor given a series resistance ωL/Q at the corner, so that each loses energy at the rate σ = 2πfc/Q. The power absorbed in the inductors, as a fraction of the available power, against frequency; beside it the lossless ladder filter's delay, D = |t|²τ₂₁ + |ρ|²τ₁₁, times σ — the stored energy over the available power, times the loss rate. At Q 100 the absorption peaks at 10.53% at 0.957 of the corner, where σ·D is 11.24%; between 0.3 and 0.95 of the corner the two agree to 7%, the rest being the split between magnetic and electric energy and the terms of second order in the loss. The slider is the inductors' Q.

The heat a delay predicts

A lossy LC ladder filter absorbs power where it stores energy, and a lossless ladder filter stores energy in exact proportion to its delay — the transmitted delay weighted by what it transmits plus the reflected delay weighted by what it reflects. So the droop of a lossy filter is its loss rate times that delay: with equal losses in inductors and capacitors, to 0.09% at Q 10,000. With inductors of Q 100 in a fifth-order Chebyshev, 10.5% of the available power is absorbed at the band edge against 11.2% predicted. Inductor loss alone misses only by the split between magnetic and electric energy — near one in the passband, 4.6 to one at 1.6 times the corner — and the dual ladder filter mirrors the split. The law is first order, and it overstates the band-edge peak by 17.5/Q.

filters · Filter termination
An L-section whose coil has a Q of 50 and whose capacitor has a Q of 1000. computed by solving, not by drawing at 89 ratios, the loss read as one minus power into the load over power into the section. It follows Qₛ(1/Qcoil + 1/Qcap) (dashed) to 3% wherever it is under 2%: at a ratio of 20 it is 8.39% against 9.15%. Two parts of Q 95.2 each — the harmonic mean of 50 and 1000 — lose 8.40% there (faint), and within 0.4% of the unequal pair at every ratio: the section hardly cares which part is lossy, only what the two reciprocals sum to.

The part that decides the match

An L-section's loss is not twice its Q over the components' Q unless the two components are equally good. Given a coil of Q 50 and a capacitor of Q 1000, a 50 Ω to 1 kΩ match loses 8.39%, which is what two parts of Q 95.2 — the harmonic mean — would lose: the reciprocals of the two Qs add, each weighted by the loaded Q, and 95% of the heat is in the coil. Both parts carry the same circulating energy, so they share the loss in the inverse ratio of their Qs, which makes the coil the one to spend on: Q 50 to 100 halves the loss, and past the capacitor's own Q a better coil buys almost nothing. The high-pass section, with each part in the other arm, loses the same to 0.01%; per hundred watts delivered the coil runs at 4.36 W; and the ratio above which splitting the match pays, 9 to 10, does not move with the parts at all.

frequency · Series-parallel
A pi network matching 50 Ω to 1 kΩ at a loaded Q of 8, coil Q 100, capacitor Q 1000. computed by solving, not by drawing at 10 design Qs from √19 = 4.36 — the least a pi network can have, at which it is the L-section and loses 4.58% — upwards. At a Q of 8 it loses 9.47% (solid) and its band for |Γ| under 0.1 is 2.3% of the frequency (dashed, scaled to the left end), against 4.7% for the L-section. At 30 it loses 28.73% for a band of 0.6%. The chosen Q is paid for in both currencies at once.

The Q a pi network makes a designer choose

An L-section has no choice of Q; a pi network adds a third part and can be built at any loaded Q above √(ratio − 1). Matching 50 Ω to 1 kΩ with coils of Q 100 and capacitors of Q 1000, it is the L-section at its least Q of 4.36 — 4.58% lost, a band of 4.7% — and at a Q of 8 it loses 9.47% for a band of 2.3%; at 30, 28.7% for 0.6%. What the extra loss buys is rejection: the second harmonic 16.0 dB down at the least Q, 29.8 at Q 10, 39.1 at 30. A tee network, with two coils where the pi has one, loses within 0.8% of the pi at every Q, because the loss follows the energy the Q makes the network circulate rather than the number of coils that carry it. And the freedom runs one way only: no pi or tee is less selective than the L-section; a lower Q needs more sections.

frequency · Series-parallel
Five readings of one passive ladder network, each taken forwards and backwards. computed by solving, not by drawing; every reading built as its own netlist, never converted from another. Transimpedance (current in, open-circuit voltage out), transadmittance (voltage in, short-circuit current out) and the reverse voltage gain against minus the forward current gain all give a ratio of one, to 1.0e-13. The voltage gain forwards against backwards does not: 1.000 at 100 Hz, 2.129 at 1 MHz. Nor does the current gain.

The readings that come back the same

Reciprocity is usually stated as 'swap the source and the meter and the reading is unchanged', and that is true of some readings and false of others. On one passive ladder network the transimpedance, the transadmittance, and the reverse voltage gain against the forward current gain each come back the same to 10⁻¹³, while the voltage gain forwards and backwards differ by 13.1 times at 82.5 kHz — exactly z₂₂/z₁₁. A 600-to-50-ohm pad has voltage gains of 0.0426 and 0.511 and one power gain both ways. A controlled source breaks all three reciprocal pairs by the same factor.

networks · Reciprocity
A fifth-order Chebyshev ladder built from parts of Q = 100: its passband sags by 0.94 dB near the edge and 0.38 dB at low frequency — 8.686·δ·τg, the group delay times the dissipation. computed by solving, not by drawing. A doubly terminated 0.5 dB Chebyshev ladder, fifth order, 1 kHz edge, 1 kΩ terminations, lossless (dashed) and with every inductor given a series resistance and every capacitor a shunt conductance for a uniform dissipation δ = ωc/Q = 62.8 s⁻¹ (solid), and the lossless response plus 8.686·δ·τg(f), with τg read off the lossless filter's phase (dots). The prediction holds to 3.6% of the extra loss across the passband. The extra is smallest where the delay is smallest, 0.383 dB at 38 Hz, and largest at 953 Hz near the edge, 0.943 dB, where the delay peaks at 1.79 ms: the ripple the design specified is rounded off where it was steepest.

The derivative that is a delay

A doubly terminated ladder filter is stationary in every element's value at its ripple peaks, and that insensitivity says nothing about the parts' losses. Give every reactance the same dissipation δ — a series resistance δL in each inductor, a shunt conductance δC across each capacitor — and every reactance has the impedance it had at s + δ, so the lossy ladder is exactly H(s + δ). By the Cauchy–Riemann equations the loss then rises by 8.686 times δ times the group delay, in decibels: the derivative of a ladder filter's response with respect to its parts' dissipation is its group delay. Solved with the resistors in, a fifth-order 0.5 dB Chebyshev of Q = 100 parts sags 0.383 dB at low frequency and 0.943 dB near its edge, where the delay peaks at 1.79 ms, the law holding to 3.6%. The sag falls as one over Q, grows with the order — 0.37 dB at third order, 2.74 at ninth — and is set by the mean of the inductors' and capacitors' dissipations.

networks · Sensitivity
A 4:1 load on a cable of 3 dB matched loss costs the cable 1.53 dB more: the standing wave makes the line lossier, by up to the mismatch loss. computed by solving, not by drawing. The extra loss — power into the line over power reaching the load, beyond the matched line's — against the matched loss, for loads giving a standing-wave ratio of 1, 1.5, 2 and 4: 10·log((a² − |Γ|²)/(a(1 − |Γ|²))) − 10·log a (lines), with a 200 Ω load on a 50 Ω line solved exactly as a line whose loss is all series resistance (dots). At a ratio of 4 the extra is 0.109 dB on a 0.1 dB line, 0.82 on a 1 dB line, 1.53 on 3 dB and 1.94 on 20 dB — rising towards the mismatch loss 10·log(1/(1 − |Γ|²)) = 1.94 dB, which it reaches when the reflected wave is burnt before it can return.

The heat a standing wave leaves

A cable improves a mismatch's apparent return loss by twice its own loss because the reflection is burnt on the way back, and the burning is not free: it is extra loss in the cable. For one unit delivered to a load reflecting |Γ| through a line of matched loss a, the line must be fed (a² − |Γ|²)/(a(1 − |Γ|²)). A 4:1 load on a 3 dB cable costs 1.53 dB more than a matched one; on a 20 dB cable, 1.94 dB, which is exactly the mismatch loss, because by then every reflected watt is heat. Short lines multiply their dissipation by (1 + |Γ|²)/(1 − |Γ|²), long ones by 1/(1 − |Γ|²). Solved exactly on a line whose loss is in its conductor, the heat stands where the current does: the hottest point runs at the standing-wave ratio times a matched line's, 4.04 against 4.00, so a power rating limited by temperature falls by the ratio, not by the average.

lines · Line loss