Concept

Line loss — where it appears

The power dissipated in the conductors carrying a supply rather than in the load at the end of them. It is proportional to the sum of the squared conductor currents, which for three phases splits exactly into one additive term per symmetrical component with no cross term between them.

Named by 5 essays across 2 fields — each of them below, with the objects they name alongside it.

Below 910 kHz a trace is a diffusion, not a line — and its velocity goes as √f. computed by solving, not by drawing. The phase velocity of an ordinary FR-4 trace against frequency, computed from γ = √((R + jωL)(G + jωC)) with a series resistance that rises as √f above its skin-effect corner and a shunt conductance proportional to frequency. Above 910 kHz the velocity is 0.4767c and does not move, which is the number every other essay in this field uses. Below it the series resistance dominates the reactance, the line is a diffusion, and the velocity falls as the square root of frequency — measured at the 0.467 power. The characteristic impedance is not a constant down there either: 1508 Ω at a kilohertz against 50.0 Ω at ten gigahertz.

The delay that is not one number

Nine essays in this field quote a delay: a length divided by a velocity, the same for every frequency, and the edge that comes out is the edge that went in. A real trace has a series resistance, and below the frequency where the reactance overtakes it — 910 kilohertz for ordinary copper — the line is a diffusion rather than a wave, with a velocity proportional to √f. What survives is that the arrival is still exactly linear in the length. What does not is the rise time, which grows as the square of it.

lines · Dispersion
The two sequences a neutral current says nothing about. computed by solving, not by drawing at 61 imbalances. Three 20 Ω loads on a 230 V, 50 Hz star supply, one of them raised by a fraction of itself, with the neutral in place. The zero-sequence current is the one the neutral carries three times and is the only one a neutral ammeter reads; the negative sequence is a balanced set of three phasors rotating the other way. At 30.0 per cent imbalance it is 0.8846 A against 10.6154 A of positive sequence, 8.333 per cent, against 8.333 per cent from x/(3 + 2x). Two per cent arrives at 6.250 per cent imbalance, bisected on the network.

The half the neutral does not carry

A star load unbalanced in one phase produces two things, not one. The neutral carries three times the zero-sequence current, which is the half a neutral ammeter reads; the other half is a negative-sequence set of exactly the same size, rotating backwards, that the neutral never sees. With 0.5 Ω of line in front of 20 Ω loads, losing a phase entirely puts 50.00 per cent negative sequence in the current and 0.8265 per cent in the voltage a switchboard meter reads.

power · Three-phase
A permittivity quoted as one number falls 0.645 across five decades. computed by solving, not by drawing. The real part of the relative permittivity against frequency for FR-4 (ε′ = 4.4 at 1 GHz, tanδ = 0.02), from a continuum of relaxations spread uniformly in log-frequency — the arrangement that makes the loss tangent flat. The dashed line is the single number a datasheet quotes. FR-4: 4.787 at 1 MHz and 4.142 at 100 GHz, a fall of 14.7 per cent. Nothing here is fitted: the slope is what a flat loss tangent forces.

The permittivity a loss forbids

A datasheet quotes a relative permittivity and a loss tangent as two independent numbers, and they are not two numbers. A material that dissipates has a permittivity that falls logarithmically with frequency at a rate its own loss fixes — 0.129 of permittivity a decade for FR-4, so the 4.4 quoted at a gigahertz is 4.79 at a megahertz and 4.14 at a hundred. Three hundred millimetres of track loses 62.9 picoseconds of delay between 100 MHz and 10 GHz, which a constant permittivity puts at 1.3; and the constant-permittivity model smears an edge backwards, taking 180 picoseconds to reach half height and 133 more to reach nine tenths.

lines · Dispersion
The delay of 50 Ω FR-4 track against frequency, with nothing dispersing, the dielectric causal, and the conductor causal as well. computed by solving, not by drawing at 108 frequencies on one track: 4.4 and a loss tangent of 0.02 at a gigahertz, 2 Ω/m of copper rising as √f above 1 MHz. Held constant (faint), the delay is flat above the resistance's corner. With the permittivity allowed to disperse (dashed), it falls 209.6 fs/mm from 100 MHz to 10 GHz. With the conductor's internal reactance put beside its resistance (solid), it falls 464.4 fs/mm over the same two decades: 7.389 ps/mm at 100 MHz, 7.094 at 1 GHz, 6.925 at 10 GHz.

The conductor made causal too

A dielectric that loses energy must disperse, and the essay before this one made FR-4's permittivity do so: the track's delay then falls 209.6 fs/mm from 100 MHz to 10 GHz. The copper has the same obligation. A conductor whose resistance rises as √f has an internal impedance (1 + j) times that rise, and putting the reactance beside the resistance more than doubles the fall, to 464.4 fs/mm — the conductor's share largest at low frequency, 418 of 584 fs/mm between 10 and 100 MHz, and the dielectric's constant at about 100 a decade. On a 30 ps edge after 300 mm the toe sharpens from 74.5 to 55.6 ps and the tail stretches from 221 to 398: the rise time is 453 ps against 295, and the tail-over-toe ratio a scope can read is 8.0 at 400 mm against 2.6.

lines · Dispersion
A pair with one conductor over glass-rich laminate (4.6, tan δ 0.015) and one over resin-rich (4.2, tan δ 0.025): the skew per millimetre against frequency. computed by solving, not by drawing: each conductor as its own causal line — permittivity dispersing with its own loss tangent, copper with its internal reactance — and the skew as the difference of their delays. With both permittivities held at their 1 GHz values the skew would be 0.318 ps/mm at every frequency (level line). Dispersing, it is 0.272 ps/mm at 100 MHz, 0.319 at 1 GHz and 0.366 at 10 GHz: the resin, lossier, loses permittivity faster with frequency, and the gap between the two halves widens.

The skew that moves with frequency

A pair with one half over glass-rich laminate and one over resin-rich builds 0.318 ps of skew a millimetre when each permittivity is held at its 1 GHz value. But the two regions lose differently — tan δ 0.015 against 0.025 — so their permittivities fall at different rates, and the skew is a curve: 0.272 ps/mm at 100 MHz, 0.319 at 1 GHz, 0.366 at 10 GHz. A deskew set at one frequency leaves ±2.35 ps in 50 mm at the other two. The resin half also loses 3.7 dB more by 10 GHz over 200 mm, so its edge arrives 63.7 ps early and rises in 257 ps against 202; the halves differ in timing and in edge rate at once, and leave a common-mode pulse of 151 mV for each volt.

lines · Dispersion

Named alongside it

The objects these essays reach for when they reach for this one.

DispersionRise timeModel rangePropagation constantCharacteristic impedancePermittivitySkin effectVerificationDesign tradeoffDifferential lineImbalanceLine impedance