A switch and a capacitor that follow a signal while the switch is closed and keep its last value once it opens. It is bounded by two errors of the one switch: the on-resistance lagging behind while it tracks, and the open switch feeding through and leaking while it holds.

Named by 6 essays across 4 fields — each of them below, with the objects they name alongside it.

The charge that comes back: a 0.2% dielectric, 10 s shorted, read at 900 s. computed by solving, not by drawing. The capacitor is charged to 10 V until every relaxation is complete, shorted for 10 seconds, then opened and watched. It climbs back to 20.00 millivolts — 0.2000 per cent of where it was — and the shape is the finding: it is a straight line on a logarithmic time axis, gaining 0.097 per cent of the charging voltage per decade. There is no time constant after which it is over, because there is no single time constant: one branch of the model comes to equilibrium per decade, for as many decades as the dielectric has. A decade before the reading it was at 0.1033 per cent.

The capacitor that remembers

Charge a capacitor, short it for ten seconds, open it, and it climbs back to a fifth of a per cent of where it was. Nothing leaked and nothing was gained: some of the dielectric had not finished discharging. The same defect measured as an admittance says the part is 0.593 per cent more capacitance at a tenth of a millihertz than at a kilohertz, and measured in a sample-and-hold it says a millisecond of hold costs a hundred parts per million — thirteen bits, on a part specified at nothing.

transients · Dielectric absorption
A hold capacitor's band closes at 6.43 MHz, where a resistor's does. computed by solving, not by drawing. The switch of 0.5 Ω closed, 100 MΩ open and 5 pF across it, driving a capacitor. The lower edge is the smallest capacitance onto which the open switch feeds through no more than 1%: 495 pF far above 318 Hz, rising as the reciprocal of frequency below it because the leakage charges the capacitor. The upper edge is the largest capacitance the closed switch tracks to 1%, counted as a vector. The two meet at 6.43 MHz; a resistor on the same switch closes at 6.43 MHz, and counted as a magnitude the capacitor's band closes at 91.6 MHz. At the closure the closed switch's phase is 0.57 degrees.

The width no load can change

A switch's band was drawn against a load resistor and closed at 6.43 megahertz. Put a hold capacitor where the resistor was and the band changes axis and shape — a diagonal below 318 hertz, a floor of 495 picofarads above it — and stays exactly as wide: 1.8083 decades at 100 kilohertz for both loads, closing at 6.43 megahertz for both. Count the capacitor's error as a magnitude, as the resistor's always was, and the band appears to stay open to 91.6 megahertz. That extra room is 8.11 degrees of lag the count cannot see.

limits · Ideal switch
Driven through 1kΩ, the absorbing capacitor's tail is 2.6e-5 of the step, not 1%. computed by solving, not by drawing. The error at a capacitor's terminal after a step applied through 1k ohms, where the capacitor is 1 nF with eight absorption branches spread over two decades from 0.1 ms, together holding one per cent of its capacitance. The poles are found by bisection and the residues in closed form, and a trapezoidal march of the same netlist agrees. The tail the branches leave is 2.58e-5 of the step — the source resistance over the branch resistances in parallel — and settling to 1e-5 takes 173µs against 11.5µs with no branches; the model that weights each branch by its share of the capacitance says 48.4ms.

The tail the source decides

A capacitor with one per cent of dielectric absorption does not leave a one-per-cent tail in the circuit it is in. Driven through a kilohm, the eight slow branches that model the absorption leave 2.58×10⁻⁵ of the step at its terminals — the source resistance over the branch resistances in parallel — and settling to 10⁻⁴ takes 9.49 µs against 9.21 with no absorption at all. The share of the capacitance is not the amplitude; it is a ceiling the circuit reaches only when the source's own time constant falls inside the spread of the branches, and there the cost is 2.2 times the settling at 10⁻⁴ and 16 times at 10⁻⁵.

transients · Doublet
With 1 RC of tracking, sixteen samples average like 7.8 independent ones. computed by solving, not by drawing. The rms noise on the average of N consecutive held samples of a 1 pF capacitor, against N, for track times of 0.25, 1, 3 and 10 RC between samples, with the 1/√N law for independent samples dotted. A sample shares exp(−Tₜ/RC) of its value with the one before, so at 1 RC the correlation is 0.368 and sixteen samples are worth 7.81 independent ones; 1,024 are worth 473.6. The closed form is checked against a seeded march of the held sequence.

The average that is not N times quieter

Averaging sixteen samples of a 1 pF capacitor is supposed to take its 63.3 µV of kT/C noise down by four. With one RC of tracking between samples it takes it down by 2.8: the switch has not been closed long enough for the capacitor to forget the last sample, each shares 37 per cent of its value with the one before, and sixteen samples are worth 7.8 independent ones. At a quarter of an RC they are worth 2.6. Sampling faster never helps past a ceiling: however quickly the samples come, an average gathers at most one independent sample per 2RC of time — the continuous average's own limit. And a sampler that settles its signal to 8 bits has already waited long enough for its noise.

noise · kT/C noise
An integrator of 100 kΩ and 1 µF with its input grounded: what its own input currents do to it. computed by solving, not by drawing, marched for ten seconds from rest. With 50 nA flowing out of each input and the + input grounded, the output ramps at 50.0 mV/s — the bias current over the capacitance, to six figures — and reaches 0.500 V. With 100 kΩ in the + input to balance the resistances, only the 5 nA of offset current is left and the ramp is 5.00 mV/s. Neither stops: an integrator has no gain to quote, because its gain is time.

The current a capacitor adds up

An amplifier's input current in a resistor is an offset; in a capacitor it is a rate, and time is the gain. An integrator of 100 kΩ and 1 µF with its input grounded ramps at 50.0 mV/s from 50 nA, and balancing the inputs leaves the 5.00 mV/s of the offset current, still unbounded. A leak resistor bounds it at the current times the leak and costs the lowest frequency the circuit integrates. A hold capacitor's droop times its acquisition time is fixed, so 50 nA through a 100 Ω switch needs 655 nF and 0.77 ms for half a 16-bit step. A charge amplifier's offset times its low corner is Ib/2πCf, whatever its bleed.

instruments · Input bias current
A 0.2% part sampling 0 V after long at 10 V, holding 1 ms: the first reading is 109 ppm of the step, and the hundredth still 4.5 ppm, every one of them made from the same branches. computed by solving, not by drawing: the reading at each sample, as a fraction of the step, when a sample-and-hold with a 1 µF part of 0.2% absorption samples 0 V after a long time at 10 V, acquiring for 100 µs and holding for 1 ms. The first reading agrees with a march of the netlist. It is 109 ppm, the tenth 46.7 ppm, the hundredth 4.5 ppm and the four-hundredth 0.904 ppm. The earlier samples are still being read, and for far longer than an acquisition suggests, because each acquisition can reach a branch only in proportion to the fraction of its time constant it lasts.

The sample before the sample

A sample-and-hold whose capacitor has 0.2 per cent of dielectric absorption reads a 10 V step 109 parts per million wrong on the first sample after it, 46.7 on the tenth, and 4.5 on the hundredth, because every earlier sample is still in the dielectric. That error has been described as distortion, since it grows with the signal. It is not. The state is linear and one period is a single matrix, so the reading is a fixed weighted sum of earlier samples, a filter with a very long tail: a sine reads 28.1 parts per million low and its largest harmonic is 1.5 × 10⁻¹² of the fundamental. A filter can be undone. Subtracting fifty earlier samples takes a stepped signal from 51.6 parts per million to 1.61, and with the absorption known to 20 per cent it stops at 5.47.

transients · Dielectric absorption