Concept

Continued fraction expansion — where it appears

A continued-fraction expansion writes a ladder's driving-point impedance as nested series and shunt terms, one per element, from the far end inwards. It is exact rather than approximate, and its denominator is the network's characteristic polynomial, so the poles follow from it directly.

Named by 3 essays across 2 fields — each of them below, with the objects they name alongside it.

One per cent on one component, in two realisations of the same order-5 filter. computed by solving, not by drawing. The two realisations agree to 3e-14 dB before anything is moved. Moving each element in turn by 1%, the worst deviation at the 2 ripple peaks is 0.1621 dB for the cascade and 0.0030 dB for the LC ladder — 54 times smaller. Across the whole passband the two are within 3% of each other, because near the band edge both are dominated by the response's own steepness rather than by the realisation.

A ladder is not a cascade

The same fifth-order Chebyshev, built two ways. A one per cent component moves the buffered cascade's passband by 0.162 dB at the ripple peaks and the doubly terminated LC ladder's by 0.003 dB — fifty-four times less. The number is not the claim: the claim is the exponent. Fitted over two decades of tolerance the cascade's error grows as the 0.99 power and the LC ladder's as the 2.00 power, because at maximum power transfer the response is stationary in every element it contains.

filters · Filter tradeoff
The ladder's step response, and the sum of its own stages — 0.95 per cent apart at worst. computed by solving, not by drawing. A step of power into a three-stage thermal ladder, and the junction's rise divided by it. The solid curve is exact: the impedance is a continued fraction in s, its denominator has 3 real negative roots, and the partial-fraction expansion of Z(s)/s is a sum of that many ordinary exponentials — no march, no step size. The dashed curve is the sum every account of a thermal path writes, each stage's own resistance times 1 − exp(−t/RC) with its own local time constant, and it is an approximation because the stages load each other. What that costs is 0.950 per cent, once, at 12.9 ms — between the fastest stage's 2.4 ms and the next one's 200 ms, which is the only place two stages are moving together. It is one-sided: the sum never reads low.

Two ladders the terminals cannot tell apart

A thermal path drawn as a ladder and the same path drawn as a sum of exponentials are called different models of one object, and the difference between them has never been priced because pricing it needs an exact answer. Solved in closed form, the sum is 0.950 per cent high at worst and never low; the marched netlist is right to a part in 21,169; and the largest disagreement in the picture was 2.919 per cent that has nothing to do with heat at all, which reading the curve one sample differently removes.

transients · Reverse-recovery
The load alternates with parity between 1 and 1.9841, at every order. computed by solving, not by drawing. The last quotient of the continued fraction that turns a reflection polynomial into element values, which is the load resistance the design demands, drawn against order. A Butterworth returns exactly one at every order. A Chebyshev alternates: one at every odd order and 1.984056 at every even one, the same number each time, and it is the closed form (√(1+ε²)+ε)² to a part in 10¹⁵. The mechanism is in the last two rows of the panel. A lossless ladder is two resistances at direct current, so it must deliver the maximum available power there, which requires that zero be one of the frequencies the design reflects nothing at — and an even-order Chebyshev's reflection zeros are the roots of an even Chebyshev polynomial, none of which is zero. The synthesis stalls at order 9 for a Butterworth, which is why that series stops at eight.

The termination an even order cannot have

Every even-order Chebyshev ladder terminates in 1.984056 times its source resistance at half a decibel of ripple, the same number at orders two, four, six and eight, and it is (√(1+ε²)+ε)² to a part in 10¹⁵. Building one between equal terminations instead — which is what a table of g-values and a matched pair gives — turns 0.5000 dB of ripple into 1.8123 at order four, deletes one of the passband maxima outright, and moves the worst tolerance corner from the 2.000 power of the component tolerance to the 1.109 power: a factor of 95 at one per cent parts.

filters · Filter termination

Named alongside it

The objects these essays reach for when they reach for this one.

Component sensitivityDoubly terminated ladderMaximum power transferAvailable powerChebyshevClosed formEquirippleFilter orderLumped approximationMarchingModel rangePoles

All concepts