Concept

Electrical length — where it appears

A conductor's length as a fraction of the wavelength it carries, which decides whether it is a node in a circuit or a transmission line. The crossover is a length rather than a frequency for a given edge, which is why a rule about stubs is quoted in millimetres.

Named by 3 essays across 2 fields — each of them below, with the objects they name alongside it.

10.0 cm of track, solved as a lumped circuit and as a line. The two agree to 0.030% at 3.97 MHz, where the track is one degree long, and to 30.1% at 143 MHz, where it is a tenth of a wavelength. Above that the lumped model is not approximately right; it is describing a different object.

Kirchhoff's own frequency

The current law says the current entering a node equals the current leaving it at the same instant, which assumes the signal crosses the circuit in no time. It crosses at about two-thirds the speed of light, so the law has a frequency of its own — set by nothing but the physical size of the board.

limits · Lumped-element
The return under 10.0 cm of track, 200 µm above the plane. computed by solving, not by drawing, as an estimate from the geometry: a low-frequency path assumed to be three track-widths wide, 83.3 mΩ, and the parallel-plate inductance µ₀h/w, 125.7 nH, which is the limit for a track much wider than its height. The estimated resistance and reactance are equal at 106 kHz. Solved across the plane instead of assumed, the return does not change path at one frequency: it gathers beneath the track across a band about three decades wide, and this corner falls inside that band. Above the band the loop is the track's length times its height, 20.0 mm², and a milliamp round it at 100 MHz radiates -1.1 dBµV/m at three metres.

Where the current comes back

The return current under a track spreads out at low frequency and runs directly beneath it at high. Estimated from two paths chosen in advance, the change is a corner at 106 kilohertz for any track two hundred micrometres above a half-milliohm plane, with neither the length of the track nor its width in it. Solved, it is a band three decades wide rather than a corner, and the width enters it after all — but the length is still absent and the stack-up still sets the top, which is the part of the argument a designer needs.

lines · Return path
From 50 Ω into 50 Ω: a T isolates to 643 MHz, a changeover to 6.34 MHz. computed by solving, not by drawing. The fraction of the drive that arrives with the path open, against frequency, from a 50 Ω source into 50 Ω, for the 0.5 Ω, 100 MΩ, 5 pF switch used three ways. A T reaches 1% at 643 MHz; a changeover reaches 1% at 6.34 MHz; one switch reaches 1% at 3.18 MHz.

The capacitance a third switch moves

A changeover's open channel leaks into the source of the channel that is closed, so its isolation into fifty ohms falls from 643 megahertz with a buffered source to 6.34 megahertz with a fifty-ohm one. Put a third switch to ground between two series switches and the leak lands on half an ohm of closed switch instead: 814, 643 and 2,240 megahertz from sources of nothing, fifty ohms and a kilohm, rising forty decibels a decade where a changeover's rises twenty. The price is the shunt switch's own capacitance, moved under the closed path, which makes the T one per cent wrong as a waveform at 6.59 megahertz beside the changeover's 6.61.

limits · Ideal switch

Named alongside it

The objects these essays reach for when they reach for this one.

Lumped-elementParasiticsDecouplingDesign tradeoffLoadingLoop areaModel rangeOff isolationOn-resistancePropagation velocityQuadratureReturn current

All concepts