Thermal runaway — where it appears
Named by 5 essays across 3 fields — each of them below, with the objects they name alongside it.
The heat a recovery leaves behind
The essay below this one measured how much current a diode conducts backwards and for how long, and stopped there. Both numbers are multiplied by a voltage somewhere, and the surprise is where: while the junction is still conducting it holds almost nothing, so nine tenths of the energy is dissipated in the transistor pulling the current down and not in the diode. Repeat it a hundred thousand times a second and it is 1.5 watts, the lifetime rises with temperature, and above 1.28 megahertz the diode's own loop has no fixed point at all.
Two loops, and one heatsink
The rung below this one found that nine tenths of a reverse recovery's energy is dissipated in the transistor and not in the diode, and then computed the diode's junction temperature with all of that energy in it. Repaired, the diode alone survives to 1.28 megahertz instead of 128 kilohertz — a factor of exactly the ninety per cent. What replaces the number is the arrangement that exists: two devices with two different positive temperature loops on one piece of aluminium, giving out at 135 kilohertz, and it is the switch that goes.
The pulse the heatsink does not feel
A thermal resistance iterated to a fixed point with a diode or a switch is a statement about a power — so it assumes that a hundred and fifty watts for two per cent of the time is three watts. The die's own heat capacity decides whether that is true, and it decides it at a frequency: above 308 hertz the junction integrates, by a hundred kilohertz the fixed point is exact to five parts in ten thousand, and at one hertz the same average power on the same heatsink puts the junction three hundred kelvin hotter.
The loop gain one temperature understates
Every thermal loop gain this collection has computed was computed at a single temperature, because a lumped fixed point has only one — and the essay that measured the gradient inside a core recorded, without measuring it, that this makes each of those numbers a lower bound. It is a lower bound by three per cent where a ferrite usually sits and by thirty-eight per cent at the well-cooled end, always in the direction that makes the part safer than the calculation said. The obvious candidate for what decides it is refused: three geometries at one Biot number are 3.3 times apart.
The boundary that is a starting point
A wound part with a stable operating point at 88.8 degrees and an ignition temperature at 191.1 will never reach the second, because nothing takes it there. Marched in time rather than solved for its steady states, the same equation says what does: a trajectory starting at 189.6 degrees settles back and one starting at 192.6 leaves the material's range in twelve seconds — two starts three kelvin apart. And an overload of four times the normal loss is survivable for ever, while seven times is survivable for seventeen minutes.
Named alongside it
The objects these essays reach for when they reach for this one.
Design tradeoffModel rangeReverse-recoverySwitching lossCarrier lifetimeFixed pointMarchingModel refusalTemperature coefficientThermal resistanceVerificationCore