Concept

Temperature coefficient — where it appears

The fractional change in a component's value per kelvin, which is systematic rather than random and therefore does not average away. A matched pair cancels the first-order part of it exactly and leaves the offset divided by the absolute temperature, whatever the mismatch.

Named by 17 essays across 9 fields — each of them below, with the objects they name alongside it.

A diode's drop from 250 to 400 K, at 1.00 mA. computed by solving, not by drawing. Thirty-one operating points, each Newton's method on the exponential at its own temperature. The drop falls at 1.828 mV/K measured against 1.830 mV/K from the closed form — falls, although the thermal voltage in the exponent rises, because the saturation current rises faster. Over the same range the slope per decade of current goes the other way, from 49.6 mV to 79.4 mV, because that one is Vₜ ln 10 and nothing else.

Two millivolts a kelvin, and the wrong sign

Every number in the semiconductor field was computed at 300 K, and the model had no temperature in it at all. Putting it in moves a diode's drop by 1.828 mV/K — downwards, although the thermal voltage in the exponent is rising, because the saturation current rises by nine orders of magnitude across the same range. Two temperature dependences of one device, of opposite sign, from one solve.

semiconductors · Temperature
What a 5% mismatched pair leaves behind, across 150 K. computed by solving, not by drawing. A saturation-current mismatch of 5.0% appears as an input offset of Vₜ·ln(m) — 1.2613 mV at 300 K — which is proportional to absolute temperature and therefore drifts at 4.2044 µV/K, exactly the offset divided by the temperature. That is 3333 ppm per kelvin at every mismatch on the slider, because the ratio is 1/T and contains nothing about the device. One junction on its own drifts 1.828 mV/K, 435 times harder.

What matching does about temperature

A pair cancels the 1.8 mV/K that broke the previous essay, and what it leaves behind is exact: a saturation-current mismatch of m shows up as an offset of the thermal voltage times ln(m), which is proportional to absolute temperature and therefore drifts in proportion to itself. 3 333 parts per million per kelvin, at every mismatch on the slider, because the ratio is 1/T and contains nothing about the device at all.

semiconductors · Differential pair
The best shunt drops 7.75 mV, whatever the current is. computed by solving, not by drawing. Two errors on one axis, both from solved networks: the shunt's own drop, which lowers the current that was to be measured, and the amplifier's 5.0 µV of offset divided by the voltage the shunt develops. The first rises with the burden voltage and the second falls, so the worst case has an interior minimum at 7.7460 mV — the geometric mean of the offset and the 12 V supply — where the error is 0.1291%, being twice the root of the offset over the supply. Neither the shunt's resistance nor the current appears in either number: at 1 A the answer is 7.75 mΩ, and at a hundred times the current it is the same burden voltage across a hundredth of the resistance. What does depend on the current is the 7.7 mW the shunt then dissipates, and 40 K of self-heating at 50 ppm/K is 0.2000% on its own. The third curve is the shunt's own Johnson noise in a kilohertz of measurement bandwidth, as a fraction of the current: it is 4.5e-6% at the best burden and is the only line here that moves with the current at all, falling as one over its square root — so above about an ampere it leaves the bottom of these axes entirely and is drawn nowhere rather than flattened onto the floor.

The ammeter that is a resistor

Every direct measurement of a current is a measurement of a voltage across something the current was made to flow through, so the instrument has two errors pointing opposite ways: a larger shunt changes the current, a smaller one leaves less for the amplifier's offset to be compared with. Written in the burden voltage they are the burden over the supply and the amplifier's offset over the burden, and the best of them is at the geometric mean — 7.75 millivolts on a twelve-volt rail, with a worst-case error of 0.129 per cent. Neither number contains a resistance, and neither contains the current: ten milliamps and a hundred amps want the same 7.75 millivolts.

instruments · Current sensing
Linearising an exponential at 125 °C, and what it costs. The linear model understates the gain by 1% at 9.69 mV and by 10% at 30.2 mV. The thermal voltage at this temperature is 34.3 mV, so "small compared with Vₜ" is not the criterion — 28% of Vₜ is already 1% wrong.

The edges that move with the room

Every boundary in this collection is quoted at one temperature and most of them are functions of it. The small-signal edge is proportional to the thermal voltage, so it runs from 5.67 millivolts at −40 degrees to 9.69 at +125 — a factor of 1.71, the ratio of the absolute temperatures exactly. A realised Q is 1.54 per cent high at one end of that range and 2.58 at the other. The numbers are right; the condition attached to them was left off, and it is the same condition every time.

limits · Model edges
Nine tenths of the heat is in the switch, and above 1.28 MHz there is no temperature at all. computed by solving, not by drawing. The junction temperature a recovering diode settles at, against switching frequency, with the carrier lifetime rising as the 1.8 power of absolute temperature so that the recovery gets worse as the junction gets hotter. Each event costs 15.43 µJ when cold, of which 90% is dissipated in whatever is pulling the current down rather than in the diode: while the junction is still conducting it holds almost no voltage, and the recovered charge is delivered through the switch at the full 100 V. That energy equals the diode's own conduction loss at 29.2 kHz. The fixed point T = Ta + Rth·P(T) is iterated from the ambient upward; the junction passes its rated 150 °C at 904 kHz, and above 1.28 MHz there is no temperature that satisfies it at all — the loop has gain and the solver reports the refusal rather than the last iterate.

The heat a recovery leaves behind

The essay below this one measured how much current a diode conducts backwards and for how long, and stopped there. Both numbers are multiplied by a voltage somewhere, and the surprise is where: while the junction is still conducting it holds almost nothing, so nine tenths of the energy is dissipated in the transistor pulling the current down and not in the diode. Repeat it a hundred thousand times a second and it is 1.5 watts, the lifetime rises with temperature, and above 1.28 megahertz the diode's own loop has no fixed point at all.

transients · Reverse-recovery
A ±15% envelope on what a bridge reads permits 29 points of working capacitance. computed by solving, not by drawing. The charge-average capacitance between zero and the rated voltage — the number a reservoir or a hold capacitor obeys — against how the data sheet's stated temperature change is divided between the model's two parameters. Every point honours the envelope exactly: the measured value at zero bias with a one-volt test signal is 15 per cent from nominal at each point on each curve, by construction. The working capacitance is not. At the cold end it is anywhere from -42.9 to -13.9 per cent — 29.0 points of ambiguity at a temperature where the measured value is pinned exactly — and at the hot end from 13.9 to 36.2. Across the whole envelope that is 79.0 points against the 30 the specification bounds, a factor of 2.63. The left-hand end of the upper curve is missing because it is impossible: with the amplitude fixed, no characteristic voltage makes the measured value exceed the zero-bias capacitance.

The coefficient that is about one reading

A class II ceramic's temperature coefficient is a third printed number, and it is a coefficient of the one capacitance a data sheet reports: what a bridge sees at zero bias with a one-volt test. The model behind the part has two parameters, one number does not determine two, and every way of dividing a ±15 per cent envelope between them honours the envelope exactly while putting the working capacitance anywhere across twenty-nine points — and two parts a bridge cannot tell apart differ by 1.80 at the voltage they are used at.

frequency · Real capacitor
Two currents called saturation: one doubles every 4.49 K, the other every 8.98 K. computed by solving, not by drawing. The two current scales of one model junction against temperature, on a logarithmic axis. The saturation current of the exponential law goes as the square of the intrinsic carrier density — a cube of the temperature and the whole band gap in a Boltzmann factor — and doubles every 4.489 K at 300 K. The generation current a reverse-biased junction actually conducts goes as the density itself, with half the band gap, and doubles every 8.978 K: exactly twice as long, at every temperature. The dashed line is "doubles every ten kelvin" drawn through the generation scale, which is the current the rule belongs to. At 300 K this junction's two scales are 10 fA and 2 nA, which are its own parameters and not a property of silicon, and they become equal only at 616.8 K, or 343.6 °C.

Two currents with one name

A junction's saturation current is two currents with one name. The one in the forward law doubles every 4.49 kelvin; the one a reverse-biased junction actually conducts is generated in its depletion region, doubles every 8.98, and on this model junction is 3.06 × 10⁵ times larger at a volt of reverse bias. Doubles every ten kelvin is the second current's rule, and applied to the first it turns the forward drop's −1.81 millivolts per kelvin into +0.39.

limits · Diode model
A bridge's reading turns over at 1.885 V, where the test level stops mattering. computed by solving, not by drawing. What a bridge reads is the fundamental of the charge waveform over the fundamental of the voltage, so it is a function of the bias AND of the amplitude, and a data sheet names one point of it: zero bias, one volt. The four curves are four test levels on one part. At zero bias they run from 9.999 µF down to 8.312 µF — the harder the drive the lower the reading, because the capacitance is at its maximum there and a sinusoid spends most of its time off the peak. At the rated 5 volts they run the other way, 2.000 µF up to 2.426 µF, because the curve is convex. Between them is one bias where the two effects cancel: at 1.8848 V a tenfold change of test level moves the reading by nothing at all, and that voltage is 0.6645 of the polarisation's own characteristic voltage.

The reading a data sheet does not take

A class II ceramic's temperature envelope leaves its working capacitance 29 points wide at one end and 79 across, because one printed number cannot pin a two-parameter model. One further bridge reading recovers almost all of it — and where the reading is taken decides everything. Turning the test level down to a fiftieth separates five parts a data sheet cannot tell apart by 17.76 per cent; moving the bias to half the rated voltage separates them by 176.02, and pins the working capacitance to ±0.512 per cent from a reading known to one.

frequency · Real capacitor
A tenth of a per cent of lead is 999 µε of strain that is not there. computed by solving, not by drawing. A 350 Ω quarter bridge at zero load, against the resistance in each lead. With both leads in the changing arm the output is 4.99500 mV at 350 mΩ — an apparent fractional change of 0.1998%, which at a gauge factor of 2 is 999 microstrain. With one lead in that arm and one in the arm beside it the output is zero to the last bit, at every lead resistance drawn. The lower panel is what the second arrangement costs: the sensitivity falls as 1/(1 + Rlead/R), which is 0.100% at the same lead and is a calibration constant rather than a drift.

The leads that are in the bridge

A strain gauge on the end of two long wires cannot be told from a strain gauge under load: both leads in the changing arm is bit for bit the same netlist as a quarter bridge whose fractional change is larger by twice the lead over the gauge, which at 350 milliohms on a 350 ohm gauge is 999 microstrain that is not there. Moving one of those leads into the arm beside it leaves the output at exactly zero for every lead resistance drawn, and turns a twenty-kelvin drift of 76.8 microstrain into 0.077. That factor is two over the strain being read — 999 at a thousand microstrain and 9990 at two hundred — and it costs 0.100 per cent of sensitivity.

applied · Bridge
What one temperature costs the loop gain of a part that has a gradient. computed by solving, not by drawing. The thermal loop gain of a 30 mm core, solved as a body with its own internal temperature profile and again as a single lump at that profile's mean, against the Biot number. Both are negative, so the core is a stabilising feedback either way — but the body's loop is the more negative of the two at every point, by 3.0 per cent at a Biot number of 0.108 and 38 per cent at 10.8. A lumped calculation therefore understates how stable a wound part is, and the amount it understates by is not a property of the material but of how well the surface is cooled relative to how well the inside conducts. Below a Biot number of about a tenth it is worth under two per cent and the lump is the right model; at the cooled end the part has 7 kelvin inside it and half the feedback is invisible to a single temperature.

The loop gain one temperature understates

Every thermal loop gain this collection has computed was computed at a single temperature, because a lumped fixed point has only one — and the essay that measured the gradient inside a core recorded, without measuring it, that this makes each of those numbers a lower bound. It is a lower bound by three per cent where a ferrite usually sits and by thirty-eight per cent at the well-cooled end, always in the direction that makes the part safer than the calculation said. The obvious candidate for what decides it is refused: three geometries at one Biot number are 3.3 times apart.

power · Thermal feedback
The reading is a count of decades: 1.0288 parts per thousand of them. computed by solving, not by drawing. 17 marched tests, three families of absolute time — a tenth of a second, one second and ten seconds of short — plotted against the number of decades between the short and the reading. The families lie on one another, which is the finding: the answer is not a property of the part alone and not a property of either duration, it is a count of the decades of relaxation time the test leaves in. The line is a least-squares fit through the origin at 1.0288e-3 per decade; the model's own capacitance per decade of relaxation time is α = 1.0343e-3, which nothing in the fit was told — the fit sits 0.53 per cent under it, because the charge that comes back is shared with the slow branches it came off. The worst residual is 4.80 per cent, at the narrowest ratio drawn, and 1.23 per cent over the 8 tests that are two decades wide and read before the slowest relaxation the model has; the 3 read after it fall away to 4.49 per cent, which is where the law ends. Families a hundred times apart in absolute time differ by at most 0.84 per cent, which is the whole of the collapse.

Ten seconds, and fifteen minutes

A data sheet's dielectric absorption is quoted as a property of the part. It is not: the same modelled capacitor reads 0.4050 per cent with a tenth-of-a-second short and 0.0305 per cent with a thousand-second one, and 0.0047 against 0.2948 depending on when the reading is taken. Seventeen marched tests collapse onto one line — the recovery is 1.0288 parts per thousand for every decade between the two durations — and four dielectrics the specified test declares identical read a factor of 3.31 apart one decade away from it.

transients · Dielectric absorption
A half-decibel filter that meets one decibel at 25 °C and does not at 89. computed by solving, not by drawing. The passband ripple of a fifth-order 0.5 dB Chebyshev built from three Sallen–Key sections, against temperature, with a part whose gain-bandwidth at 300 K is 300 kHz against a 1 kHz corner. Not one passive component has a temperature coefficient in this model. The ripple is 0.824 dB at −40 °C and 1.049 at +125, and it crosses a one-decibel specification at 88.6 °C — a boundary in temperature, which every other edge in this collection is not. The dashed line is the same filter with a tail current proportional to absolute temperature: 0.916 dB at both ends, and no crossing anywhere.

The ripple that is a temperature

The rung below found that an amplifier a hundred times the corner leaves a section's quality factor two per cent high. That two per cent has a temperature in it: with a tail current a resistor sets, the transconductance falls as one over absolute temperature, and a fifth-order half-decibel design whose passives have no temperature coefficient at all goes from 0.82 decibels of ripple at minus forty to 1.05 at a hundred and twenty-five — crossing a one-decibel specification at 89 °C. With the other bias it does not move at all.

filters · Q enhancement
Two leads nobody counts cost 1995 parts per million, and two more leads remove all of it. computed by solving, not by drawing. The error in the reported strain against the resistance in each of the two excitation leads, at 1000 µε on a quarter bridge of 350 Ω excited at 10 V. With four wires the instrument takes the excitation to be the supply's voltage, so every reading is scaled by R/(R + 2r): 1995 parts per million at 0.35 Ω, 54029 at 10. Two more leads brought back from the bridge's own terminals, carrying only the instrument's input current, leave 3.5e-4 parts per million. Exciting with a current instead of a voltage does the same thing with no extra leads at all, because the lead resistance is in series with a source that does not care.

The two leads nobody counts

The leads that are in the bridge moved a lead out of the changing arm and turned a 999-microstrain error into nothing. The two leads carrying the excitation are still there, and they scale every reading: 0.35 ohms each on a 350-ohm bridge is 1,995 parts per million, exactly −2r/(R + 2r), the same on a full bridge as on a quarter one, and drifting 0.153 microstrain over twenty kelvin — twice what the three-wire fix left behind. Two more wires brought back from the bridge's own terminals leave 0.00035 parts per million. So does exciting the bridge with a current, which needs no extra wires at all.

applied · Bridge
The direct-current error a bigger feedback resistor does not fix. computed by solving, not by drawing, at direct current with the amplifier in the netlist. A 1.0 nA photocurrent into 100 MΩ gives -0.100 V. The bias current flows in the same resistor, so its contribution is the ratio of the two currents — 0.1000% at 25 °C, and the same percentage at 1 MΩ and at 1 GΩ, which is checked by changing the resistor rather than by reading an expression. The amplifier's 100 µV of offset behaves the other way: it is multiplied by one plus the resistor over the diode's own leakage, so it grows with the resistor and with temperature. Both terms double every ten kelvin, for two different reasons, and at 85 °C they are 6.40% and 0.740% against 0.100% and 0.110% at 25.

The error a bigger resistor cannot help

Every other quantity in a photodiode amplifier improves with a larger feedback resistor: the signal grows as R and the resistor's own noise as √R, so the ratio goes as √R. The bias current does not behave like either — it flows in the same resistor the signal does, so its contribution is the ratio of the two currents with the resistance cancelled, 0.1 per cent at 25 °C and the same 0.1 per cent at a megohm and at a gigohm. The offset behaves the other way, growing as one plus the resistor over the diode's own leakage, and at 85 °C the two are 6.40 and 0.74 per cent against 0.10 and 0.11 at room temperature.

feedback · Transimpedance
A diode thermometer measuring its own sense current, at 600 K/W. computed by solving, not by drawing. The same fixed point as the core and the thermistor, on a junction: the dissipation is I·V and V falls with temperature, so the loop gain is negative and the equation has one root at every current. What it costs is two errors. The junction sits above ambient by 0.29 millikelvin at a microamp and 4.26 kelvin at ten milliamperes, which a calibration removes; and a kelvin of ambient produces less than a kelvin of junction, by 1/(1 − R_th·dP/dT), which it does not. After a calibration at 25 degrees the reading at 85 is out by -583 millikelvin at ten milliamperes and -0.09 at a microamp. The coefficient itself moves too — -2.403 against -1.613 millivolts a kelvin — so a quoted tempco carries a sense current as well as a junction.

The sensor inside its own answer

A junction driven from a current source cannot run away, because its forward voltage falls with temperature and its loop gain is therefore negative. What that costs is a thermometer that is warmer than what it is measuring by 4.26 kelvin at ten milliamperes, and — the part a calibration cannot remove — under-reports every change in ambient by 9,584 parts per million, because the sense current's own dissipation falls as the reading rises. Calibrated at 25 degrees, it is out by 583 millikelvin at 85.

semiconductors · Thermal feedback
The shunt's resistance as a function of what it is measuring. computed by solving, not by drawing, as a fixed point: the shunt dissipates I²R, its temperature rises by 20 K per watt, and at 50 ppm/K its resistance rises with its temperature — so the resistance the reading is divided by depends on the reading. Iterated to convergence it agrees with the closed form R₀/(1 − αθI²R₀) to 2.2e-16. Along the burden-voltage optimum, where R = u⁄I, the dissipation is I·u rather than I²R, so the temperature rise is 155 mK per ampere and the error is the FIRST power of the current — fitted exponent 1.0007 over five decades. That is the only one of the shunt's errors with the current in it, and it puts a term in I² into the reading, which is a curvature no single-current calibration removes. The upper curve is a shunt of fixed resistance, where the error is quadratic. The fixed point stops existing at 129 kA and never at a current a shunt will see.

The resistance that depends on the reading

Three of a shunt's errors are free of the current being measured, which is the whole content of the burden-voltage optimum. The fourth is not: the shunt dissipates, warms, and its resistance rises — so the divisor the reading uses is a function of the reading. Solved as a fixed point it agrees with R₀/(1 − αθI²R₀) to 2×10⁻¹⁶, and along the optimum, where the dissipation is I·u* rather than I²R, the error is the FIRST power of the current: 7.75 ppm at an ampere, 775 at a hundred, fitted exponent 1.0007.

instruments · Current sensing
With 100 pA of junction leakage at 25 °C, a T keeps 2.8 bits over one switch and loses them all by 91 °C. computed by solving, not by drawing, at direct current, at every five kelvin from 0 to 150 °C. The floor — the least worse-of-two error any load gives — of a 0.5 Ω, 100 MΩ switch alone and as a T of three, from a buffered source, with a junction leakage of 100 pA at 25 °C on every terminal, doubling every 10 K, the worse sign taken. At 25 °C the lone switch's floor is 71.06 ppm (13.78 bits) and the T's 9.998 ppm (16.61 bits). The T is worse than one switch above 91.4 °C, where the junction current equals the off-resistance's conductance at one volt. The lone switch drops below 13 bits at 101.3 °C and below 12 at 125.9 °C; the T below 16 at 37.2 °C.

The leak no switch can hold

A T of three switches reaches five parts per billion because its shunt switch holds the node a leak has to cross. A junction leakage does not cross anything: it flows out of the outer switch's terminal straight into the load. With 100 picoamperes of it at 25 °C, doubling every ten kelvin, the T's floor is 9.998 parts per million rather than five parts per billion — 16.61 bits, not 27.6 — and it has a best load again, at 100 kilohms. A lone switch loses nothing at room temperature. Above 91.4 °C, where the junction current reaches the off-resistance's conductance at one volt, the T is worse than one switch.

limits · Ideal switch

Named alongside it

The objects these essays reach for when they reach for this one.

Model rangeMeasurement conditionDesign tradeoffThermal voltageComponent toleranceFour-terminal sensingInput offsetNonlinearitySaturation currentVerificationBand gapExcitation

All concepts