Temperature coefficient — where it appears
Named by 17 essays across 9 fields — each of them below, with the objects they name alongside it.
Two millivolts a kelvin, and the wrong sign
Every number in the semiconductor field was computed at 300 K, and the model had no temperature in it at all. Putting it in moves a diode's drop by 1.828 mV/K — downwards, although the thermal voltage in the exponent is rising, because the saturation current rises by nine orders of magnitude across the same range. Two temperature dependences of one device, of opposite sign, from one solve.
What matching does about temperature
A pair cancels the 1.8 mV/K that broke the previous essay, and what it leaves behind is exact: a saturation-current mismatch of m shows up as an offset of the thermal voltage times ln(m), which is proportional to absolute temperature and therefore drifts in proportion to itself. 3 333 parts per million per kelvin, at every mismatch on the slider, because the ratio is 1/T and contains nothing about the device at all.
The ammeter that is a resistor
Every direct measurement of a current is a measurement of a voltage across something the current was made to flow through, so the instrument has two errors pointing opposite ways: a larger shunt changes the current, a smaller one leaves less for the amplifier's offset to be compared with. Written in the burden voltage they are the burden over the supply and the amplifier's offset over the burden, and the best of them is at the geometric mean — 7.75 millivolts on a twelve-volt rail, with a worst-case error of 0.129 per cent. Neither number contains a resistance, and neither contains the current: ten milliamps and a hundred amps want the same 7.75 millivolts.
The edges that move with the room
Every boundary in this collection is quoted at one temperature and most of them are functions of it. The small-signal edge is proportional to the thermal voltage, so it runs from 5.67 millivolts at −40 degrees to 9.69 at +125 — a factor of 1.71, the ratio of the absolute temperatures exactly. A realised Q is 1.54 per cent high at one end of that range and 2.58 at the other. The numbers are right; the condition attached to them was left off, and it is the same condition every time.
The heat a recovery leaves behind
The essay below this one measured how much current a diode conducts backwards and for how long, and stopped there. Both numbers are multiplied by a voltage somewhere, and the surprise is where: while the junction is still conducting it holds almost nothing, so nine tenths of the energy is dissipated in the transistor pulling the current down and not in the diode. Repeat it a hundred thousand times a second and it is 1.5 watts, the lifetime rises with temperature, and above 1.28 megahertz the diode's own loop has no fixed point at all.
The coefficient that is about one reading
A class II ceramic's temperature coefficient is a third printed number, and it is a coefficient of the one capacitance a data sheet reports: what a bridge sees at zero bias with a one-volt test. The model behind the part has two parameters, one number does not determine two, and every way of dividing a ±15 per cent envelope between them honours the envelope exactly while putting the working capacitance anywhere across twenty-nine points — and two parts a bridge cannot tell apart differ by 1.80 at the voltage they are used at.
Two currents with one name
A junction's saturation current is two currents with one name. The one in the forward law doubles every 4.49 kelvin; the one a reverse-biased junction actually conducts is generated in its depletion region, doubles every 8.98, and on this model junction is 3.06 × 10⁵ times larger at a volt of reverse bias. Doubles every ten kelvin is the second current's rule, and applied to the first it turns the forward drop's −1.81 millivolts per kelvin into +0.39.
The reading a data sheet does not take
A class II ceramic's temperature envelope leaves its working capacitance 29 points wide at one end and 79 across, because one printed number cannot pin a two-parameter model. One further bridge reading recovers almost all of it — and where the reading is taken decides everything. Turning the test level down to a fiftieth separates five parts a data sheet cannot tell apart by 17.76 per cent; moving the bias to half the rated voltage separates them by 176.02, and pins the working capacitance to ±0.512 per cent from a reading known to one.
The leads that are in the bridge
A strain gauge on the end of two long wires cannot be told from a strain gauge under load: both leads in the changing arm is bit for bit the same netlist as a quarter bridge whose fractional change is larger by twice the lead over the gauge, which at 350 milliohms on a 350 ohm gauge is 999 microstrain that is not there. Moving one of those leads into the arm beside it leaves the output at exactly zero for every lead resistance drawn, and turns a twenty-kelvin drift of 76.8 microstrain into 0.077. That factor is two over the strain being read — 999 at a thousand microstrain and 9990 at two hundred — and it costs 0.100 per cent of sensitivity.
The loop gain one temperature understates
Every thermal loop gain this collection has computed was computed at a single temperature, because a lumped fixed point has only one — and the essay that measured the gradient inside a core recorded, without measuring it, that this makes each of those numbers a lower bound. It is a lower bound by three per cent where a ferrite usually sits and by thirty-eight per cent at the well-cooled end, always in the direction that makes the part safer than the calculation said. The obvious candidate for what decides it is refused: three geometries at one Biot number are 3.3 times apart.
Ten seconds, and fifteen minutes
A data sheet's dielectric absorption is quoted as a property of the part. It is not: the same modelled capacitor reads 0.4050 per cent with a tenth-of-a-second short and 0.0305 per cent with a thousand-second one, and 0.0047 against 0.2948 depending on when the reading is taken. Seventeen marched tests collapse onto one line — the recovery is 1.0288 parts per thousand for every decade between the two durations — and four dielectrics the specified test declares identical read a factor of 3.31 apart one decade away from it.
The ripple that is a temperature
The rung below found that an amplifier a hundred times the corner leaves a section's quality factor two per cent high. That two per cent has a temperature in it: with a tail current a resistor sets, the transconductance falls as one over absolute temperature, and a fifth-order half-decibel design whose passives have no temperature coefficient at all goes from 0.82 decibels of ripple at minus forty to 1.05 at a hundred and twenty-five — crossing a one-decibel specification at 89 °C. With the other bias it does not move at all.
The two leads nobody counts
The leads that are in the bridge moved a lead out of the changing arm and turned a 999-microstrain error into nothing. The two leads carrying the excitation are still there, and they scale every reading: 0.35 ohms each on a 350-ohm bridge is 1,995 parts per million, exactly −2r/(R + 2r), the same on a full bridge as on a quarter one, and drifting 0.153 microstrain over twenty kelvin — twice what the three-wire fix left behind. Two more wires brought back from the bridge's own terminals leave 0.00035 parts per million. So does exciting the bridge with a current, which needs no extra wires at all.
The error a bigger resistor cannot help
Every other quantity in a photodiode amplifier improves with a larger feedback resistor: the signal grows as R and the resistor's own noise as √R, so the ratio goes as √R. The bias current does not behave like either — it flows in the same resistor the signal does, so its contribution is the ratio of the two currents with the resistance cancelled, 0.1 per cent at 25 °C and the same 0.1 per cent at a megohm and at a gigohm. The offset behaves the other way, growing as one plus the resistor over the diode's own leakage, and at 85 °C the two are 6.40 and 0.74 per cent against 0.10 and 0.11 at room temperature.
The sensor inside its own answer
A junction driven from a current source cannot run away, because its forward voltage falls with temperature and its loop gain is therefore negative. What that costs is a thermometer that is warmer than what it is measuring by 4.26 kelvin at ten milliamperes, and — the part a calibration cannot remove — under-reports every change in ambient by 9,584 parts per million, because the sense current's own dissipation falls as the reading rises. Calibrated at 25 degrees, it is out by 583 millikelvin at 85.
The resistance that depends on the reading
Three of a shunt's errors are free of the current being measured, which is the whole content of the burden-voltage optimum. The fourth is not: the shunt dissipates, warms, and its resistance rises — so the divisor the reading uses is a function of the reading. Solved as a fixed point it agrees with R₀/(1 − αθI²R₀) to 2×10⁻¹⁶, and along the optimum, where the dissipation is I·u* rather than I²R, the error is the FIRST power of the current: 7.75 ppm at an ampere, 775 at a hundred, fitted exponent 1.0007.
The leak no switch can hold
A T of three switches reaches five parts per billion because its shunt switch holds the node a leak has to cross. A junction leakage does not cross anything: it flows out of the outer switch's terminal straight into the load. With 100 picoamperes of it at 25 °C, doubling every ten kelvin, the T's floor is 9.998 parts per million rather than five parts per billion — 16.61 bits, not 27.6 — and it has a best load again, at 100 kilohms. A lone switch loses nothing at room temperature. Above 91.4 °C, where the junction current reaches the off-resistance's conductance at one volt, the T is worse than one switch.
Named alongside it
The objects these essays reach for when they reach for this one.
Model rangeMeasurement conditionDesign tradeoffThermal voltageComponent toleranceFour-terminal sensingInput offsetNonlinearitySaturation currentVerificationBand gapExcitation