Bulk resistance — where it appears
Named by 4 essays across one field — each of them below, with the objects they name alongside it.
The constant that is a window
A diode's ideality factor is quoted as a number and defined as a derivative, which means it has a value at every current and no value anywhere. Eight one-decade fits to one curve return factors from 1.23 to 1.98, two of them straight to a few parts in a thousand — so the residual gives no warning at all. Asked for the forward voltage at a milliamp, the window containing it is right to a third of a millivolt and the worst is out by 186, which is a current a hundredth of the truth.
The resistance a slow curve cannot see
A diode's series resistance is read off the top of its forward curve, and a bench curve is a slow one: each point is held until the junction has warmed to it. Through 350 kelvin per watt the held curve sits 39.7 millivolts below the pulsed one at 100 milliamps, and the three-parameter fit that reads 0.580 ohms from the pulsed curve reads 0.184 from the held one — with a smaller residual. The fitted resistance reaches zero at 531.7 kelvin per watt, and the resistance it hid is what keeps the junction from folding back: with 0.05 ohms instead of 0.6 the held curve turns over at 87.6 milliamps.
The logarithm is in the collector
A diode is the textbook logarithm, and a real junction holds one to within one per cent over only 2.40 decades — from 50 nanoamps to 12.6 microamps, at an ideality of 1.98 — because two mechanisms and a series resistance share its terminals. The same junction read at a transistor's collector, with its recombination current supplied from the base, holds 8.50 decades at an ideality of 1.0001. How far the logarithm reaches is decided by which terminal the current is taken from, and at the bottom of the range by a leakage current a millivolt is enough to switch on.
The straight line between two models
Between a constant seven-tenths of a volt and an exponential sits the model a designer actually reaches for: a drop plus a resistance. Fitted so that its worst error over a decade of current is as small as it can be, it is out by ±8.00 millivolts where the best constant is out by ±29.76 — and both numbers are the same over every decade, because a decade of a logarithm is the same shape wherever it is taken. On a real two-mechanism junction the line does best in the top decade, ±8.71 against a constant's ±58.53, because a series resistance is exactly the term the line has and the constant has none. And the resistance the fit returns is the part's plus 701 milliohms that is not there.
Named alongside it
The objects these essays reach for when they reach for this one.
Ideality factorMeasurement conditionModel rangeOperating pointDynamic resistanceLinearisationSaturation currentThermal voltageDesign tradeoffLeakage currentLoop gainPower law fit