Saturation current — where it appears
Named by 9 essays across 4 fields — each of them below, with the objects they name alongside it.
The one current a constant is right at
Seven-tenths of a volt is the true forward drop at 5.748 milliamperes and at no other current, and every circuit built on it crosses zero error there — four different resistors at four different supplies, all exact at the same current. What decides whether the model is any good is not the diode at all; it is how much of the supply the diode is taking.
Two millivolts a kelvin, and the wrong sign
Every number in the semiconductor field was computed at 300 K, and the model had no temperature in it at all. Putting it in moves a diode's drop by 1.828 mV/K — downwards, although the thermal voltage in the exponent is rising, because the saturation current rises by nine orders of magnitude across the same range. Two temperature dependences of one device, of opposite sign, from one solve.
The constant that is a window
A diode's ideality factor is quoted as a number and defined as a derivative, which means it has a value at every current and no value anywhere. Eight one-decade fits to one curve return factors from 1.23 to 1.98, two of them straight to a few parts in a thousand — so the residual gives no warning at all. Asked for the forward voltage at a milliamp, the window containing it is right to a third of a millivolt and the worst is out by 186, which is a current a hundredth of the truth.
Two currents with one name
A junction's saturation current is two currents with one name. The one in the forward law doubles every 4.49 kelvin; the one a reverse-biased junction actually conducts is generated in its depletion region, doubles every 8.98, and on this model junction is 3.06 × 10⁵ times larger at a volt of reverse bias. Doubles every ten kelvin is the second current's rule, and applied to the first it turns the forward drop's −1.81 millivolts per kelvin into +0.39.
The logarithm is in the collector
A diode is the textbook logarithm, and a real junction holds one to within one per cent over only 2.40 decades — from 50 nanoamps to 12.6 microamps, at an ideality of 1.98 — because two mechanisms and a series resistance share its terminals. The same junction read at a transistor's collector, with its recombination current supplied from the base, holds 8.50 decades at an ideality of 1.0001. How far the logarithm reaches is decided by which terminal the current is taken from, and at the bottom of the range by a leakage current a millivolt is enough to switch on.
Two exponentials, and where they meet
An oscillator's envelope grows by exp(π(k−3)/√(1 − ((k−3)/2)²)) a cycle, and the form usually quoted drops the denominator — exact to four parts in ten million at a hundredth above three, and 20.462 per cent low at 3.8, which is precisely where too few small cycles are left to measure it. Where the growth stops is the diode's own exponential: 108.5 millivolts of amplitude for every decade of saturation current, proportional to the ideality to four parts in a thousand. Above 60.121 nanoamperes the limiter is already conducting at zero signal and there is no oscillation at all.
The junction that is a resistor at zero volts
A forward-biased junction makes half the noise power of a resistor of its own dynamic resistance, and that half is a limit rather than a value. Kept with the saturation current that flows backwards across it, the ratio is one exactly at zero volts, 0.5676 at 50 millivolts, and within one per cent of the half only above 115.1 — at ninety-nine saturation currents, which is a picoampere on a small silicon diode and a microampere on a leaky one. A photodiode held at zero volts has the Johnson noise of its shunt resistance and nothing else, and it becomes shot-noise-limited at 49.981 millivolts of photocurrent drop.
The sensor inside its own answer
A junction driven from a current source cannot run away, because its forward voltage falls with temperature and its loop gain is therefore negative. What that costs is a thermometer that is warmer than what it is measuring by 4.26 kelvin at ten milliamperes, and — the part a calibration cannot remove — under-reports every change in ambient by 9,584 parts per million, because the sense current's own dissipation falls as the reading rises. Calibrated at 25 degrees, it is out by 583 millikelvin at 85.
The mismatch that cancels itself
A current mirror's copy error is spread by three things the two transistors can differ in, and the population that measures it has always drawn all three at once. Turned on one at a time, a two per cent spread of saturation currents gives 1.910 per cent of copy error and a two per cent spread of current gains gives 0.00022 — because the gains enter only as a sum of reciprocals, which has no first derivative where they are equal. Then the standard cure un-cancels it, by a factor of 86.
Named alongside it
The objects these essays reach for when they reach for this one.
Thermal voltageModel rangeIdeality factorOperating pointMeasurement conditionTemperature coefficientBand gapBulk resistanceDesign tradeoffDynamic resistanceLeakage currentLinearisation