Common-impedance — where it appears
Named by 4 essays across 3 fields — each of them below, with the objects they name alongside it.
The millivolts in the wire
Ten millimetres of one-ounce copper is five milliohms and ten nanohenries, and if a hundred-milliamp load and a ten-millivolt sensor both return through it, half a millivolt of somebody else's current is added to the reading — five per cent of it, before anything has been amplified. Above 79.6 kilohertz the error rises a decade per decade with no ceiling, and shortening the shared run moves the whole curve down and the corner not at all.
The rejection four resistors decide
Measuring a ten-millivolt sensor against a ground that somebody else's hundred milliamps is also using puts five hundred microvolts of their current into the reading. Subtracting the two ends of that conductor with a difference amplifier removes it — by 53.99 decibels with one-tenth-per-cent resistors, against a closed form of 53.98, which is a factor of five hundred and not a removal. The amplifier has nothing to do with it: the number is one plus the gain over four times the resistor tolerance.
The floor and the ceiling move apart
A decoupling bank is judged by two numbers — the lowest impedance it reaches and the highest frequency at which it still meets its target — and with no copper between the parts and the load both improve together as capacitors are added, 5.000 milliohms down to 1.500 and 19.8 megahertz up to 162. Three nanohenries of ordinary board separate them. The bank's own floor still falls 3.33 times while the load's falls 1.49, and the ceiling read at the parts climbs to 82.4 megahertz while the load's peaks at 8.06 and falls to 5.05. At twenty parts the two nodes disagree by a factor of 94 about the same solve.
The rail the load moves
Seven rungs of this ladder end by saying the same thing: the supply is an ideal voltage source, so a load step is drawn from a node that cannot be disturbed. Giving the rail an impedance turns out to change the disturbing channel's own output impedance by three parts in ten million — its loop corrects the supply along with everything else — and to open a path to a second amplifier that shares nothing with it but a wire. How large that path is is a modelling choice: 3.84 microvolts per ampere with the compensation capacitor returned to ground, 17.3 millivolts with it returned to the rail, a factor of four and a half thousand.
Named alongside it
The objects these essays reach for when they reach for this one.
DecouplingLead resistanceLoadingModel rangeParasiticsReturn currentVerificationCapacitive loadCommon-mode rejectionComponent toleranceCrosstalkDifference amplifier