Decoupling — where it appears

Placing capacitance beside a device so its rapid current comes from there rather than along the supply, over the band where the pair is a capacitor. Above the pair's own self-resonance the capacitor is an inductor, so the band it works over has a top as well as a bottom.

Named by 8 essays across 4 fields — each of them below, with the objects they name alongside it.

A 100 nF capacitor, and what it is above 14.5 MHz. The dashed line is 1/(ωC), which is what the symbol means. The solid line is the same part with 30 mΩ of series resistance and 1.2 nH of series inductance, solved. They part company at 4.69 MHz and by a decade above resonance the part's impedance is 99.0× what its capacitance predicts.

The capacitor that is an inductor

A hundred-nanofarad capacitor follows 1/(2πfC) for four decades and then turns round and climbs. Above 14.5 MHz it is an inductor, and a decade past that its impedance is ninety-nine times what its capacitance predicts — all of it caused by about a nanohenry of lead and via that nobody chose and nobody drew.

frequency · Real capacitor
The return under 10.0 cm of track, 200 µm above the plane. computed by solving, not by drawing, as an estimate from the geometry: a low-frequency path assumed to be three track-widths wide, 83.3 mΩ, and the parallel-plate inductance µ₀h/w, 125.7 nH, which is the limit for a track much wider than its height. The estimated resistance and reactance are equal at 106 kHz. Solved across the plane instead of assumed, the return does not change path at one frequency: it gathers beneath the track across a band about three decades wide, and this corner falls inside that band. Above the band the loop is the track's length times its height, 20.0 mm², and a milliamp round it at 100 MHz radiates -1.1 dBµV/m at three metres.

Where the current comes back

The return current under a track spreads out at low frequency and runs directly beneath it at high. Estimated from two paths chosen in advance, the change is a corner at 106 kilohertz for any track two hundred micrometres above a half-milliohm plane, with neither the length of the track nor its width in it. Solved, it is a band three decades wide rather than a corner, and the width enters it after all — but the length is still absent and the stack-up still sets the top, which is the part of the argument a designer needs.

lines · Return path
An inverting unity gain driving 2.2 nF, and the pole that is inside the loop. computed by solving, not by drawing. Two ten-kilohm resistors around a 10 MHz amplifier make a gain of 1.00, and a loop that closes against 2.01 — one plus the ratio, not the ratio. Hanging 2.2 nF on the output leaves the closed-loop gain at a kilohertz unchanged — 0.99998002 against 0.99997988 — and takes the phase margin from 90.0° to 30.1°. The mechanism is at the other end of the amplifier from the summing-junction case and the arithmetic is the same: the load works against the amplifier's own fifty ohms of output resistance, which puts a second pole in the forward path — inside the loop, where the feedback has to live with it — while the gain the loop closes against does not move at all. Forty-five degrees is reached at 905 pF, bisected on the netlist. The capacitance is not part of the signal path and does not appear in any expression for the gain.

The load that gets inside the loop

Hanging a capacitor on an amplifier's output changes nothing a reader can find in any expression for its gain, and takes the phase margin of a unity-gain inverter from ninety degrees to thirty. The mechanism is fifty ohms of output resistance that no data sheet page puts next to the stability page: the load works against it, the pole that results is in the forward path, and forty-five degrees arrives at 905 picofarads — which is a metre of coaxial cable.

feedback · Capacitive load
A ±15% envelope on what a bridge reads permits 29 points of working capacitance. computed by solving, not by drawing. The charge-average capacitance between zero and the rated voltage — the number a reservoir or a hold capacitor obeys — against how the data sheet's stated temperature change is divided between the model's two parameters. Every point honours the envelope exactly: the measured value at zero bias with a one-volt test signal is 15 per cent from nominal at each point on each curve, by construction. The working capacitance is not. At the cold end it is anywhere from -42.9 to -13.9 per cent — 29.0 points of ambiguity at a temperature where the measured value is pinned exactly — and at the hot end from 13.9 to 36.2. Across the whole envelope that is 79.0 points against the 30 the specification bounds, a factor of 2.63. The left-hand end of the upper curve is missing because it is impossible: with the amplitude fixed, no characteristic voltage makes the measured value exceed the zero-bias capacitance.

The coefficient that is about one reading

A class II ceramic's temperature coefficient is a third printed number, and it is a coefficient of the one capacitance a data sheet reports: what a bridge sees at zero bias with a one-volt test. The model behind the part has two parameters, one number does not determine two, and every way of dividing a ±15 per cent envelope between them honours the envelope exactly while putting the working capacitance anywhere across twenty-nine points — and two parts a bridge cannot tell apart differ by 1.80 at the voltage they are used at.

frequency · Real capacitor
A bulk capacitor and a ceramic, and the peak between them at 6.52 MHz. computed by solving, not by drawing. Each capacitor is three elements — its capacitance, its series resistance and its series inductance — and a one-amp source drives the node, so the node voltage is the impedance. Alone, each dips to its own series resistance at its own self-resonance and rises on either side. Together they do not: between the two resonances the bulk part is an inductor and the ceramic is still a capacitor, and an inductance across a capacitance is a parallel resonance. The pair reaches 1.187 Ω at 6.52 MHz, where the bulk alone would give 0.2023 Ω and the ceramic alone 0.2055 — 5.87 times worse than either. The dashed curves are the two parts on their own; the solid one is what the load actually sees.

The pair that is worse than either

A bulk capacitor and a ceramic are fitted together because each is good where the other is not, and between them is a frequency at which the pair presents six times the impedance either one does alone. The peak is a parallel resonance between one part's inductance and the other's capacitance, its height is one over the series resistance every data sheet asks to be minimised, and at it the two capacitors exchange 5.87 amps for every amp the load draws.

power · Decoupling
Three nanohenries of copper move the peak to 5.63 MHz and raise it to 1.29 Ω. computed by solving, not by drawing. The same two capacitors, with and without the inductance of the way to them: one nanohenry of mounting loop per part and two nanohenries of plane between the bank and the load. The dashed curve is the bank as the rung below drew it, peaking at 1.187 Ω at 6.52 MHz; the solid one is what the load sees, peaking at 1.293 Ω at 5.63 MHz. The peak moves down because the branch that is inductive at that frequency got more inductive, and it rises for the same reason. Above about twenty megahertz the two part company entirely: the bank is still falling toward its parts' own resistances and the load is rising on two nanohenries that no capacitor is across.

The capacitor that is not where the load is

The rung below this one connects two capacitors to a load through nothing, and says so. Put three nanohenries of ordinary copper in — one of mounting loop per part and two of plane between the bank and the load — and the anti-resonance moves down to 5.63 megahertz and up to 1.29 ohms, a probe touching the ceramic reads a twelfth of what the load sees at 16.7 megahertz and three and a half times too much at 8.35, and the twentieth capacitor is worse than the second.

power · Decoupling
The bank reaches 1.500 mΩ and the load sees 141.5 mΩ at that same frequency. computed by solving, not by drawing. One bulk part and 20 ceramics, with a nanohenry of mounting loop each and two nanohenries of plane between the bank and the load, solved once per frequency and read at both nodes. The dashed curve is the bank's own node — what a probe on the parts measures. The solid one is the load. The bank's least impedance is 1.500 mΩ at 11.3 MHz, and at that frequency the load sees 141.5 mΩ, which is 94.3 times more, against 141.5 mΩ of plane reactance at that frequency. Whatever the parts do, the load's reading cannot fall below the reactance of the copper in front of them, and the parts reach their best by moving up the frequency axis into it.

The floor and the ceiling move apart

A decoupling bank is judged by two numbers — the lowest impedance it reaches and the highest frequency at which it still meets its target — and with no copper between the parts and the load both improve together as capacitors are added, 5.000 milliohms down to 1.500 and 19.8 megahertz up to 162. Three nanohenries of ordinary board separate them. The bank's own floor still falls 3.33 times while the load's falls 1.49, and the ceiling read at the parts climbs to 82.4 megahertz while the load's peaks at 8.06 and falls to 5.05. At twenty parts the two nodes disagree by a factor of 94 about the same solve.

power · Decoupling
One channel's load step reaches another through the supply, and the compensation decides by 4497×. computed by solving, not by drawing. Two identical amplifiers on one rail — sharing no signal node — with an ampere of load step pulled from the first and the second's output read. With the wiring left out the coupling is exactly zero, which is what the seven rungs below this one computed. With 30 nanohenries and fifty milliohms of rail and 10 microfarads of decoupling it is not: 3.84 microvolts per ampere at 271 kHz if the compensation capacitor returns to ground, and 17.29 millivolts per ampere at 2.33 MHz if it returns to the rail. That is a factor of 4497 decided by a modelling choice, which is why both are drawn. The channel that caused the step is unaffected: its own loop corrects the disturbance along with everything else, and the crosstalk is entirely a problem for the channel that did not.

The rail the load moves

Seven rungs of this ladder end by saying the same thing: the supply is an ideal voltage source, so a load step is drawn from a node that cannot be disturbed. Giving the rail an impedance turns out to change the disturbing channel's own output impedance by three parts in ten million — its loop corrects the supply along with everything else — and to open a path to a second amplifier that shares nothing with it but a wire. How large that path is is a modelling choice: 3.84 microvolts per ampere with the compensation capacitor returned to ground, 17.3 millivolts with it returned to the rail, a factor of four and a half thousand.

feedback · Capacitive load

Named alongside it

The objects these essays reach for when they reach for this one.

Equivalent series inductanceParasiticsSelf-resonanceLoop areaMeasurement conditionCapacitive loadCommon-impedanceEquivalent series resistanceImpedance matchingLoop gainModel rangeOutput impedance