Loading — where it appears
Named by 25 essays across 6 fields — each of them below, with the objects they name alongside it.
The probe is part of the circuit
A one-to-one oscilloscope probe on a two-kilohm source gives a reading that is one per cent wrong at 6.8 kHz. Not because the instrument is inaccurate — it is reading correctly — but because the hundred and fifteen picofarads at the end of the cable are across the node, and above that frequency the trace on the screen is a picture of a circuit that only exists while the probe is attached.
The divider, and the thing it does not know about
A two-resistor divider's output is set by the ratio of its resistances — with nothing connected. Connect anything at all and what decides the answer is the quantity the ratio was built to discard: the magnitude. Two dividers of identical ratio give six volts and one volt into the same load.
Two terminals measure the leads as well
Fifty milliohms in each lead makes a two-wire measurement one per cent high at ten ohms, ten per cent high at one ohm, and a hundred per cent high at a tenth. Not approximately — the reading is the resistance plus the leads, and below about ten ohms most of what is being reported is the wire between the instrument and the thing.
Which picture sets the upper edge
Every account of a transformer's high-frequency limit names the same mechanism: the leakage inductance resonating with the winding capacitance. At fifty ohms that resonance is at 1.13 MHz and the measured edge is at 81.3 kHz — a factor of fourteen away — because what actually binds is the leakage in series with the load, a first-order corner with no resonance in it at all. The two swap at about 1500 Ω, and both accounts are current because both are sometimes right.
The instrument's own rise time
Rise times add in quadrature, so ten per cent of inflation needs an instrument 2.18 times faster than the edge. That constant contains no instrument. Measured on the solved network it is 2.79 for a one-pole front end, 3.97 for two, 4.87 for three and 5.62 for four — the rule is optimistic at every pole count, which is the wrong direction for a rule of thumb to err in.
Where the band goes entirely
The three essays before this one measure a transformer's band, and all three assume there is one. Past a few hundred ohms of load there is not: the leakage that sets the upper edge is also what damps the resonance behind it, and a lightly loaded, well-coupled transformer peaks at 3.03 times its own turns ratio. A passive component with voltage gain is not a transformer behaving badly. It is a resonant circuit, and asking for its band returns the skirts of a resonance.
A band rather than an edge
Every other boundary in this collection is one-sided: a model is true below a frequency, or below an amplitude. A switch is a switch only for loads between 49.5 ohms and 1.01 megohms — bounded at both ends by the same part — and the upper end is a frequency as well as a resistance, so the band narrows as the frequency rises and shuts completely at 6.43 megahertz, above which no load resistance at all will do.
The millivolts in the wire
Ten millimetres of one-ounce copper is five milliohms and ten nanohenries, and if a hundred-milliamp load and a ten-millivolt sensor both return through it, half a millivolt of somebody else's current is added to the reading — five per cent of it, before anything has been amplified. Above 79.6 kilohertz the error rises a decade per decade with no ceiling, and shortening the shared run moves the whole curve down and the corner not at all.
The node that is at ground for a while
An inverting amplifier's summing junction is held at ground by the loop, so it is at ground exactly as well as the loop is strong. Driven with a current and measured, it is a tenth of an ohm at direct current, ten ohms at a kilohertz, and 909 ohms above a megahertz — which is the two feedback resistors in parallel, with the amplifier contributing nothing.
The rejection four resistors decide
Measuring a ten-millivolt sensor against a ground that somebody else's hundred milliamps is also using puts five hundred microvolts of their current into the reading. Subtracting the two ends of that conductor with a difference amplifier removes it — by 53.99 decibels with one-tenth-per-cent resistors, against a closed form of 53.98, which is a factor of five hundred and not a removal. The amplifier has nothing to do with it: the number is one plus the gain over four times the resistor tolerance.
The ammeter that is a resistor
Every direct measurement of a current is a measurement of a voltage across something the current was made to flow through, so the instrument has two errors pointing opposite ways: a larger shunt changes the current, a smaller one leaves less for the amplifier's offset to be compared with. Written in the burden voltage they are the burden over the supply and the amplifier's offset over the burden, and the best of them is at the geometric mean — 7.75 millivolts on a twelve-volt rail, with a worst-case error of 0.129 per cent. Neither number contains a resistance, and neither contains the current: ten milliamps and a hundred amps want the same 7.75 millivolts.
The buffer that is not a buffer
An emitter follower is reached for when something has to be driven without being loaded: unity gain in, high impedance seen, low impedance presented. The last of those is a number with a range, and the range is narrow. At a kilohm of source the emitter presents 19.08 ohms at low frequency and 67 ohms at 29 megahertz, because the current gain that made it small is falling — and the peak is worst in the middle of the slider, so it cannot be avoided by making the source stiffer or softer.
The corner the instrument has no part in
Three rungs of this argument measured a three-amplifier instrumentation amplifier's rejection at direct current and found 95 dB, of which the resistors' matching decides one part and the amplifiers' own mismatch another. Connect it to a source with a kilohm of imbalance and ten picofarads at each input and the rejection has a corner at 290 Hz and falls twenty decibels a decade after it — reaching 84 dB at a kilohertz on an instrument that is still doing 95. What converts common mode to differential is the difference of two time constants, and the cure is a capacitor on the quiet input.
What the load sees looking back
Four rungs of this argument have measured what the amplifier does to the signal — the margin, the settling, the error, the noise. None has asked the question from the other end. A load that draws its own current sees an impedance looking back, and with the feedback taken from the amplifier that impedance is the isolation resistor, with no loop gain in it whatever: ten ohms, and a load step leaves an error that never goes away. The two-path arrangement recovers to a thousandth of it and charges for that in a quantity none of the four rungs below measured.
The width no load can change
A switch's band was drawn against a load resistor and closed at 6.43 megahertz. Put a hold capacitor where the resistor was and the band changes axis and shape — a diagonal below 318 hertz, a floor of 495 picofarads above it — and stays exactly as wide: 1.8083 decades at 100 kilohertz for both loads, closing at 6.43 megahertz for both. Count the capacitor's error as a magnitude, as the resistor's always was, and the band appears to stay open to 91.6 megahertz. That extra room is 8.11 degrees of lag the count cannot see.
The probe that takes a tenth
A ten-to-one probe buys an order of bandwidth for a tenth of the signal, and on a two-kilohm source the bandwidth is exact: 6.79 kHz becomes 69.2 kHz. The tenth of the signal is not a tenth of the signal-to-noise ratio. Solved resistor by resistor, the noise referred to the tip goes from 1.782 µV to 55.78 µV — a factor of 31.3 — because the divider that does the attenuating is nine megohms and a megohm, and √(n(n−1)kT/C) on the cable's own capacitance has no source resistance in it at all.
Where an open switch leaks to
A lone switch has a band whose width no load can change, because its open state leaks into the load. In a multiplexer the seven open channels leak into a node the selected channel holds, so the load leaves the answer and the source takes its place: one per cent of leak at 91.0 megahertz from buffered sources and 901 kilohertz from fifty ohms, moving as the first power of the tolerance rather than the second. Adding the channels' capacitance into one forty-picofarad switch puts it at 804 kilohertz, near the fifty-ohm figure by coincidence and a hundred and thirteen times low for a buffered one.
The capacitance a third switch moves
A changeover's open channel leaks into the source of the channel that is closed, so its isolation into fifty ohms falls from 643 megahertz with a buffered source to 6.34 megahertz with a fifty-ohm one. Put a third switch to ground between two series switches and the leak lands on half an ohm of closed switch instead: 814, 643 and 2,240 megahertz from sources of nothing, fifty ohms and a kilohm, rising forty decibels a decade where a changeover's rises twenty. The price is the shunt switch's own capacitance, moved under the closed path, which makes the T one per cent wrong as a waveform at 6.59 megahertz beside the changeover's 6.61.
The voltmeter four wires do not remove
A four-terminal measurement is described everywhere as removing the leads from the answer. It moves them. What is left is the voltmeter's own input resistance, and it grows with the resistance being measured rather than shrinking: with a ten-megohm voltmeter and fifty milliohms of lead, the four-wire reading is 0.0100 per cent low at a kilohm, where the two-wire reading is exactly right — 1.8 × 10⁻¹² — because its lead error and its loading error cancel. Above 707 Ω the two-wire arrangement is the more accurate of the two at every resistance.
The floor below any load
A switch of half an ohm closed and a hundred megohms open is within one per cent of ideal for loads between two edges, and the edges close on each other as the tolerance tightens. At direct current they meet at 70.71 parts per million, into 7.07 kilohms: no load makes that switch better, which is 13.79 bits and a boundary with no frequency in it. A T of three such switches has no best load at all. Its error falls with the load towards five parts per billion — the square of the lone switch's resistance ratio rather than its root — and reaches ten only into two hundred megohms. Into the 7.07 kilohms that suited one switch, the T is worse than one switch.
The stage that is wrong is the far one
Three identical ten-kilohm dividers in a row give 0.076923 rather than the product of their ratios, 0.125 — 38.5 per cent low. Decomposed stage by stage with the rest of the chain in place, and the product of those three is the answer exactly, they are 0.3846, 0.4000 and 0.5000: the LAST stage is exactly its own ratio because nothing is connected to it, and the error is entirely at the front, which is the opposite end from where a probe goes. Staggering each stage's impedance up by a factor takes the departure down in proportion — fitted exponent −0.993.
The branch the other resistance decides
A voltage divider's output is set by the resistance the output is taken across; a current divider's is set by the resistance the current does not go through. The dual of a voltmeter's finite resistance is an ammeter's non-zero one, and the threshold has the same shape with one word changed: one per cent at a meter resistance of R/99 where R is what the meter looks back into — and removing an ideal current source means OPENING it, so that R is the two branches in series, 11 kΩ here, not the 909 Ω of their parallel combination — a factor of twelve in the same construction on the same network.
The shunt switch the source sizes
A T is two series switches and a third to ground, and it is always drawn with three of the same part. The shunt switch pulls its own size two ways: larger, it holds the open node harder; larger, it hangs more capacitance on the closed path. The size at which the band closes latest is a balance of the two — the fourth root of 2/ε times √(Rₒₙ/(Rₛ + Rₒₙ)) — when the closed state is counted as an amplitude — 3.8 times a series switch from a buffered source, a third of one from fifty ohms, a twelfth from a kilohm — and it buys a band 3.4, 2.7 and 13 times wider. Counted as a waveform the root of ε goes, and from a buffered source the best shunt is exactly the series switch.
The resistance that bends the signal
A switch of half an ohm and a hundred megohms has a floor of 70.71 parts per million, 13.79 bits, because its on-resistance and its off-resistance cannot both be small beside one load. Most of that floor is a gain error, and a gain error calibrates away. Give the on-resistance a realistic ten per cent of movement across the signal range and the uncalibrated floor slips to 74.16 parts per million, while the part no calibration can touch — the curvature — balances the leak at 13.89 parts per million, 16.14 bits, into 1.39 kilohms. The floor was never set by the on-resistance. It is set by how much the on-resistance moves, as its square root.
The leak no switch can hold
A T of three switches reaches five parts per billion because its shunt switch holds the node a leak has to cross. A junction leakage does not cross anything: it flows out of the outer switch's terminal straight into the load. With 100 picoamperes of it at 25 °C, doubling every ten kelvin, the T's floor is 9.998 parts per million rather than five parts per billion — 16.61 bits, not 27.6 — and it has a best load again, at 100 kilohms. A lone switch loses nothing at room temperature. Above 91.4 °C, where the junction current reaches the off-resistance's conductance at one volt, the T is worse than one switch.
Named alongside it
The objects these essays reach for when they reach for this one.
Model rangeDesign tradeoffParasiticsOff isolationOn-resistanceFour-terminal sensingLead resistanceOutput impedanceSource impedanceVoltage dividerBandwidthLow resistance measurement