Concept

Coupling coefficient — where it appears

The fraction of one winding's flux that links the other, between zero and one, and the floor on how nearly a transformer can behave as its turns ratio. What it leaves uncoupled is the leakage inductance, and that inductance sets both the upper edge of a transformer's band and its inrush behaviour.

Named by 5 essays across 2 fields — each of them below, with the objects they name alongside it.

A 1:1 transformer at k = 0.99, and the band it is a turns ratio over. computed by solving, not by drawing. Two 10 mH windings coupled at 0.99, driven from 50 Ω into 50 Ω, with 0.5 Ω of winding resistance and 100 pF across the secondary. The response is flat at 0.4901 — which is 98.02% of the 0.5000 an ideal transformer of this ratio would give, and that shortfall is the coupling itself: the flat part is k times the turns ratio, times what the two winding resistances leave of the loop, to four figures at every k on the slider — between 400 Hz and 81.3 kHz, which is 2.31 decades. Both edges are bisected on the solved network. Below the first, the magnetising inductance is a short across the source; above the second, the leakage inductance is in series with the load. The slider moves the coupling, and it moves the upper edge only.

The band a turns ratio holds over

Every model this collection has drawn is right below a number or above one. A transformer is the first that is wrong at both ends and right in the middle, and the flat part is not the turns ratio either — measured on the solve it is the turns ratio times the coupling, times what the two winding resistances leave of the whole loop — and the first version of that last factor was a coincidence that held for every coupling and broke at a different load.

magnetics · Transformer
What coupling buys: the upper edge only. computed by solving, not by drawing. Six couplings from 0.8 to 0.999, each transformer solved and both its edges bisected. The lower edge moves by 1.083× across the whole range — it is set by the magnetising inductance against the source and the reflected load, and the coupling barely enters it. The upper edge moves by 168×, from 4.84 kHz to 814 kHz, because it is set by the leakage — which is what the coupling is. Winding a better transformer widens the band at the top and does nothing at the bottom, where the answer is more inductance or a smaller load.

What coupling buys, and where it does not

Winding a transformer better is winding it more tightly coupled, and the coupling coefficient is the number a maker works on. Measured across six designs from k = 0.8 to k = 0.999, it moves the upper band edge by 168 times and the lower one by 1.083 — so every hour spent on the winding buys bandwidth at one end of the band and, to within eight per cent, nothing at all at the other.

magnetics · Transformer
Which mechanism sets the upper edge, against the load. computed by solving, not by drawing. Two candidate upper edges drawn against the measurement. The one every textbook names is a resonance between the leakage inductance and the winding capacitance; the one that actually binds at ordinary loads is the leakage in series with the load, a first-order corner at R/2πL. At 50 Ω they are 80.4 kHz and 1.13 MHz — a factor of 14 apart — and the measurement follows the first, to 19.5% at worst across nine loads. They swap at about 1500 Ω, above which the resonance is the binding one and the usual picture is right — which is why a transformer feeding a high impedance behaves as the textbooks say and one feeding fifty ohms does not.

Which picture sets the upper edge

Every account of a transformer's high-frequency limit names the same mechanism: the leakage inductance resonating with the winding capacitance. At fifty ohms that resonance is at 1.13 MHz and the measured edge is at 81.3 kHz — a factor of fourteen away — because what actually binds is the leakage in series with the load, a first-order corner with no resonance in it at all. The two swap at about 1500 Ω, and both accounts are current because both are sometimes right.

magnetics · Transformer
The coupling coefficient, from two measurements that do not know it. computed by solving, not by drawing. Two windings in series, connected one way and then the other, each solved as a netlist and its inductance read out of the impedance. The two differ by four times the mutual inductance, so k comes out of the difference and the geometry never enters. The recovered value matches the one stamped into the coupling to 2.4e-15 at eight couplings from 0.1 to 0.99 — which is the second route the new element needed, since neither current law nor the energy balance can see a mutual inductance at all. Their sum stays at L₁ + L₂ throughout, which is the check that the two measurements are of one pair.

One number from two measurements

Neither of this site's two standing checks can see a mutual inductance. A coupling adds no current anywhere, so Kirchhoff's law is unmoved by it; a coupled pair dissipates nothing, so the energy balance is unmoved too. A coupling stamped into the wrong row would produce a well-formed solution to a different circuit and both checks would pass — so the field needed a third route, and the one it uses is the bench method: connect the windings in series one way, then the other, and the difference is four times the mutual inductance.

magnetics · Mutual inductance
A part in ten thousand of ratio, and half a degree that costs 18% of a power reading. computed by solving, not by drawing. The two errors of a 1000:1 current transformer into a 10 Ω burden, read off one solve of a netlist driven by a current source. The magnetising inductance puts a high-pass under the measurement with a corner at 0.456 Hz, so the ratio error falls as the frequency rises — and stops falling at 100 parts per million, which is 1 − k and is a coupling rather than a frequency. The phase error falls too and is worth far more: 0.522° at 50 Hz is 0.0142% of the current and 18.2% of the power at a power factor of 0.05. What bounds it from above is not on this plot: the burden voltage is integrated by the core, so the largest primary current is 916 A at 50 Hz and proportionally more at 400.

The ammeter that is not in the circuit

A shunt measures a current by putting a resistance in the circuit, and every objection to it follows from that. A current transformer puts nothing in the circuit at all — a thousand-turn secondary reflects twelve microhms into the primary — and charges for it in a different currency: no response at direct current, a ratio error that stops falling at one minus the coupling, and a phase error of half a degree at fifty hertz that costs eighteen per cent of a power reading at a power factor of 0.05.

instruments · Current sensing

Named alongside it

The objects these essays reach for when they reach for this one.

TransformerLeakage inductanceMagnetising inductanceModel rangeMutual inductanceBandwidthBurden resistanceCurrent sensingCurrent transformerInterwinding capacitanceLoadingPhase error