Coupling coefficient — where it appears
Named by 8 essays across 2 fields — each of them below, with the objects they name alongside it.
The band a turns ratio holds over
Most circuit models are right below a number or above one. A transformer is wrong at both ends and right in the middle, and the flat part is not the turns ratio either — measured on the solve it is the turns ratio times the coupling, times what the two winding resistances leave of the whole loop — and the first version of that last factor was a coincidence that held for every coupling and broke at a different load.
What coupling buys, and where it does not
Winding a transformer better is winding it more tightly coupled, and the coupling coefficient is the number a maker works on. Measured across six designs from k = 0.8 to k = 0.999, it moves the upper band edge by 168 times and the lower one by 1.083 — so every hour spent on the winding buys bandwidth at one end of the band and, to within eight per cent, nothing at all at the other.
Which picture sets the upper edge
Every account of a transformer's high-frequency limit names the same mechanism: the leakage inductance resonating with the winding capacitance. At fifty ohms that resonance is at 1.13 MHz and the measured edge is at 81.3 kHz — a factor of fourteen away — because what actually binds is the leakage in series with the load, a first-order corner with no resonance in it at all. The two swap at about 1500 Ω, and both accounts are current because both are sometimes right.
One number from two measurements
Neither of the two standing checks on a solved circuit can see a mutual inductance. A coupling adds no current anywhere, so Kirchhoff's law is unmoved by it; a coupled pair dissipates nothing, so the energy balance is unmoved too. A coupling stamped into the wrong row would produce a well-formed solution to a different circuit and both checks would pass — so the field needed a third route, and the one it uses is the bench method: connect the windings in series one way, then the other, and the difference is four times the mutual inductance.
The ammeter that is not in the circuit
A shunt measures a current by putting a resistance in the circuit, and every objection to it follows from that. A current transformer puts nothing in the circuit at all — a thousand-turn secondary reflects twelve microhms into the primary — and charges for it in a different currency: no response at direct current, a ratio error that stops falling at one minus the coupling, and a phase error of half a degree at fifty hertz that costs eighteen per cent of a power reading at a power factor of 0.05.
The leakage a series reading cannot see
The series-aiding and series-opposing readings recover a coupling coefficient to fifteen figures on a netlist, and on a bench with a 0.1% meter they recover it to about 0.001 at every coupling — which is useless exactly where transformers live. At k = 0.999 the leakage, L₁(1 − k²), is two thousandths of the winding, and the series route leaves it 133% uncertain: 88 of 400 seeded benches report a negative leakage. Shorting the other winding reads the leakage directly, to the meter's own 0.1%, and recovers k 943 times more precisely at 0.999. The short is a short only where the shorted winding's reactance dwarfs its resistance by 10k/√(1 − k²), and the winding to short is the one with the longer time constant.
The band counted in rise times
A transformer's band is two frequencies and its pulse response is two times, and they are the same two facts. Through the 1:1, k = 0.99 transformer whose band runs 400 Hz to 81.3 kHz, a 100 µs pulse rises in 4.03 µs — 0.35 over the upper band edge — and droops 21.6% along its top with a time constant of one over 2π times the lower edge, 398 µs; solved by residues and by a march of the netlist, they agree to a third of a per cent. Coupling buys rise time and nothing else: from 30.8 µs at k = 0.9 to 422 ns at 0.999, while the droop's time constant moves from 414 to 396 µs. The longest pulse that droops no more than 10%, over the rise, is 0.048 times the ratio of the upper band edge to the lower — the band ratio counted in rise times, 10.4 at k = 0.99 and 98.8 at 0.999. And the droop is not lost: a transformer has no gain at direct current, so the output swings below zero afterwards by exactly what the top lost, and the two areas match to 0.08%.
The window that moves
A shorted winding reads its own leakage only above the frequency at which the short really cancels the shared flux, and only below the leakage's resonance with whatever capacitance is across it. A tighter coupling raises the first edge as one over the root of 1 − k², and it was expected to pull the second down and close the window. It raises the second as well, by the same factor. So the band is 82 Hz to 36 kHz at k = 0.9, 279 Hz to 112 kHz at 0.99 and 2.81 kHz to 1.12 MHz at 0.9999, about four hundred times wide throughout. Its width is 0.01·L₂/(R₂k√(L₁C)), with the leakage nowhere in it, so what closes the window is the winding and not the coupling. Reading the real part as well is exact on paper and limited by phase.
Named alongside it
The objects these essays reach for when they reach for this one.
TransformerLeakage inductanceMagnetising inductanceMutual inductanceBandwidthClosed formMeasurement errorModel rangeBurden resistanceCurrent sensingCurrent transformerDesign tradeoff