Leakage inductance — where it appears
Named by 13 essays across 4 fields — each of them below, with the objects they name alongside it.
The band a turns ratio holds over
Most circuit models are right below a number or above one. A transformer is wrong at both ends and right in the middle, and the flat part is not the turns ratio either — measured on the solve it is the turns ratio times the coupling, times what the two winding resistances leave of the whole loop — and the first version of that last factor was a coincidence that held for every coupling and broke at a different load.
What coupling buys, and where it does not
Winding a transformer better is winding it more tightly coupled, and the coupling coefficient is the number a maker works on. Measured across six designs from k = 0.8 to k = 0.999, it moves the upper band edge by 168 times and the lower one by 1.083 — so every hour spent on the winding buys bandwidth at one end of the band and, to within eight per cent, nothing at all at the other.
Which picture sets the upper edge
Every account of a transformer's high-frequency limit names the same mechanism: the leakage inductance resonating with the winding capacitance. At fifty ohms that resonance is at 1.13 MHz and the measured edge is at 81.3 kHz — a factor of fourteen away — because what actually binds is the leakage in series with the load, a first-order corner with no resonance in it at all. The two swap at about 1500 Ω, and both accounts are current because both are sometimes right.
Where the band goes entirely
The three essays before this one measure a transformer's band, and all three assume there is one. Past a few hundred ohms of load there is not: the leakage that sets the upper edge is also what damps the resonance behind it, and a lightly loaded, well-coupled transformer peaks at 3.03 times its own turns ratio. A passive component with voltage gain is not a transformer behaving badly. It is a resonant circuit, and asking for its band returns the skirts of a resonance.
The inductance that limits, and lifts
Adding winding resistance to a rectifier limits the first peak and does not reduce the energy at all — the essay below measured ∫i²dt as two per cent apart over a factor of four in the resistance. Adding leakage inductance does both: it divides the peak by seven and the energy by five, and dissipates nothing to do it. What it buys instead is a rectifier whose output sits 29 per cent above the peak of its own supply, permanently, which every steady-state expression in this field says cannot happen.
The inductor one mode cannot see
Two windings on one core present a millihenry to a current that goes the same way round both and a microhenry to one that goes opposite ways, so the same component has a corner at 3.98 kHz and another at 7.86 MHz — a ratio of two thousand, which is 2/(1−k) and contains no inductance at all. It is bought to remove the conversion the previous essay measured, and five picofarads across each winding turn it over at 1.59 MHz and leave it worth 0.02 decibels by ten gigahertz.
The inductance that is a shape
Leakage inductance is the one transformer parameter that belongs to the geometry rather than to the material: twice the magnetic energy in the window under equal and opposite ampere-turns, divided by the square of the current. Solved as a field it is 3.086 microhenries a metre against a closed form's 3.128 when the copper fills the window, and 4.608 against 6.255 when it fills half of it. Interleaving is worth 3.11 times and not the four it is quoted as, and the missing 0.89 is the insulation nobody puts in the formula.
The other half of the same window
The two-dimensional solve that settled what a winding's alternating-current resistance really is computed one of the window's two parameters and never mentioned the other. Read with Laplace instead of the vector potential, the same cross-section returns 926.9 picofarads a metre — and 89 per cent of that energy sits inside films that occupy 14.1 per cent of the window. The instrument agrees with a layered slab to three parts in ten thousand billion and converges on a real winding at order 1.34, and the reason for the shortfall is not the arithmetic but the corner of a conductor.
Interleaving is a choice, not an improvement
Splitting a transformer's windings into six sections divides its leakage inductance by 21.4 and multiplies its winding-to-winding capacitance by 11.0. The product of the two — which is what sets the frequency the part stops being a transformer at — moves by 1.94, and the resonance it decides goes from 1.804 to 2.515 megahertz for all that work. What interleaving really changes is the winding's characteristic impedance, 95.2 ohms down to 6.2, and nobody quotes it.
The leakage a series reading cannot see
The series-aiding and series-opposing readings recover a coupling coefficient to fifteen figures on a netlist, and on a bench with a 0.1% meter they recover it to about 0.001 at every coupling — which is useless exactly where transformers live. At k = 0.999 the leakage, L₁(1 − k²), is two thousandths of the winding, and the series route leaves it 133% uncertain: 88 of 400 seeded benches report a negative leakage. Shorting the other winding reads the leakage directly, to the meter's own 0.1%, and recovers k 943 times more precisely at 0.999. The short is a short only where the shorted winding's reactance dwarfs its resistance by 10k/√(1 − k²), and the winding to short is the one with the longer time constant.
The inductance that flattens the supply
An unregulated supply's output resistance counts each resistance by the mean current it carries, and an inductance in the winding carries the whole mean current and drops no mean voltage — so by that rule it should count for nothing. Marched, it counts for less than nothing: 0.3 mH of leakage takes the output resistance at 100 Ω from 3.88 Ω to 0.67, and the mean output falls 0.62 V from 200 Ω to 25 Ω instead of 1.69. The effect has an interior optimum — 0.03 mH makes it slightly worse, 0.3 mH best, 3 mH back to 2.86 Ω — because the inductance first rings the reservoir up and then turns the rectifier toward choke input.
The band counted in rise times
A transformer's band is two frequencies and its pulse response is two times, and they are the same two facts. Through the 1:1, k = 0.99 transformer whose band runs 400 Hz to 81.3 kHz, a 100 µs pulse rises in 4.03 µs — 0.35 over the upper band edge — and droops 21.6% along its top with a time constant of one over 2π times the lower edge, 398 µs; solved by residues and by a march of the netlist, they agree to a third of a per cent. Coupling buys rise time and nothing else: from 30.8 µs at k = 0.9 to 422 ns at 0.999, while the droop's time constant moves from 414 to 396 µs. The longest pulse that droops no more than 10%, over the rise, is 0.048 times the ratio of the upper band edge to the lower — the band ratio counted in rise times, 10.4 at k = 0.99 and 98.8 at 0.999. And the droop is not lost: a transformer has no gain at direct current, so the output swings below zero afterwards by exactly what the top lost, and the two areas match to 0.08%.
The window that moves
A shorted winding reads its own leakage only above the frequency at which the short really cancels the shared flux, and only below the leakage's resonance with whatever capacitance is across it. A tighter coupling raises the first edge as one over the root of 1 − k², and it was expected to pull the second down and close the window. It raises the second as well, by the same factor. So the band is 82 Hz to 36 kHz at k = 0.9, 279 Hz to 112 kHz at 0.99 and 2.81 kHz to 1.12 MHz at 0.9999, about four hundred times wide throughout. Its width is 0.01·L₂/(R₂k√(L₁C)), with the leakage nowhere in it, so what closes the window is the winding and not the coupling. Reading the real part as well is exact on paper and limited by phase.
Named alongside it
The objects these essays reach for when they reach for this one.
TransformerCoupling coefficientDesign tradeoffEnergy-storageInterwinding capacitanceModel rangeMutual inductanceClosed formField solutionMagnetising inductanceBandwidthLoading