Magnetising inductance — where it appears
Named by 10 essays across 4 fields — each of them below, with the objects they name alongside it.
The band a turns ratio holds over
Most circuit models are right below a number or above one. A transformer is wrong at both ends and right in the middle, and the flat part is not the turns ratio either — measured on the solve it is the turns ratio times the coupling, times what the two winding resistances leave of the whole loop — and the first version of that last factor was a coincidence that held for every coupling and broke at a different load.
What coupling buys, and where it does not
Winding a transformer better is winding it more tightly coupled, and the coupling coefficient is the number a maker works on. Measured across six designs from k = 0.8 to k = 0.999, it moves the upper band edge by 168 times and the lower one by 1.083 — so every hour spent on the winding buys bandwidth at one end of the band and, to within eight per cent, nothing at all at the other.
The ammeter that is not in the circuit
A shunt measures a current by putting a resistance in the circuit, and every objection to it follows from that. A current transformer puts nothing in the circuit at all — a thousand-turn secondary reflects twelve microhms into the primary — and charges for it in a different currency: no response at direct current, a ratio error that stops falling at one minus the coupling, and a phase error of half a degree at fifty hertz that costs eighteen per cent of a power reading at a power factor of 0.05.
The spread a winding resistance holds
A relaxation oscillator's threshold noise walks an ideal core's flux without limit. Put the winding's resistance back and the walk stops at a spread: 1.22% of a half cycle's swing when L/R is a hundred periods, growing as the square root of L/R, while a comparator skew's offset grows as L/R itself. The anticorrelation between consecutive duty errors is worth 24% of that spread at β = 0.5 and 62% at β = 0.2 — but only in a core slow enough to remember several periods. And the resistance that bounds the walk is a boundary in its own right: with a millihenry and a fifth of the swing to spare, an ohm tolerates 12.9 mV of noise, and a hundred picoseconds of skew needs at least 0.14 Ω.
The ring a blocking capacitor buys
A series capacitor in front of a transformer stops its flux from walking: a 55%-duty drive that walks a bare core by 0.40 units of volt-time a period settles within a few dozen periods once the capacitor takes the drive's average. The price is a second-order high-pass with the magnetising inductance, and an inductance lets its poles go complex where two resistive coupling stages never could. Between equal resistances the damping cannot fall below 1/√2, and the poles are complex only for a capacitor between 0.17 and 5.8 times L/R². From a stiff driver the damping is √(L/C)/2R and has no floor: a capacitor large enough to make the droop small — the droop is 1/RC, the capacitor's and not the transformer's — makes the tail ring, from one zero crossing at a tenth of L/R² to thirty-five at a hundred.
The walk that stops
A drive whose two half-cycles differ in volt-seconds walks the flux to saturation in a count of cycles, and the essay that measured it concluded that no amplitude puts the design inside a limit. That model has a stiff source and a winding of no resistance. With resistance in the loop the walk has a fixed point, held by an identity the material is not in — the mean magnetising current is the drive's direct component divided by the resistance, to seven parts in 10¹³ — and the boundary becomes a resistance rather than a time: 0.1014 ohms bisected, at a one per cent imbalance and half the volt-second limit.
The instant a transformer is worst at
A capacitor-input rectifier draws its worst inrush when it is switched on at the peak of the mains. A transformer's own magnetising branch is the other way round: switched on at the voltage zero, a 230 V primary worked at 1.4 T draws 87.6 A in its first half-cycle, 791 times its settled magnetising current, and at the voltage peak it draws nothing extra at all. The core's flux has to start from zero, the voltage does not, and how close the working flux sits to half of saturation decides the size.
The harmonic that names an inrush
A transformer's differential relay sees an inrush as current going in and nothing coming out, which is what an internal fault looks like, and it tells them apart by the second harmonic. Marched cycle by cycle, an inrush starts at 79% second harmonic and stays above the usual 15% restraint for thirty cycles — long after its current has fallen from 88 A to 205 mA, because the current unwinds in a few cycles and the flux offset under it takes seconds. A fault's offset is a smooth exponential and peaks at 14.6% only when X/R is as low as three.
The flux the reset leaves behind
A transformer driven one way only — a forward converter, a single-ended pulse transformer — is reset each cycle by letting its magnetising current fall to zero, and zero current is not zero flux. Marched on the hysteretic core, a power ferrite with 90.6 mT of remanence driven to 0.3 T starts every pulse but the first at 90.8 mT, and keeps 34.9% of the swing a symmetric drive would get, where half is the most a one-way drive could; a square-loop core starts at 212 mT and keeps 14.7%. A gap shears the loop: the current is zero where H = −lg·B/(μ₀·le), so the start is bounded by μ₀·Hc·le/lg and falls onto the bound as the gap grows — 22.0 mT at 0.1 mm, recovering 69 mT of swing for 239 mA more magnetising current. The first pulse from a demagnetised core is the only one that starts at zero, and it is the one a bench test sees.
The band counted in rise times
A transformer's band is two frequencies and its pulse response is two times, and they are the same two facts. Through the 1:1, k = 0.99 transformer whose band runs 400 Hz to 81.3 kHz, a 100 µs pulse rises in 4.03 µs — 0.35 over the upper band edge — and droops 21.6% along its top with a time constant of one over 2π times the lower edge, 398 µs; solved by residues and by a march of the netlist, they agree to a third of a per cent. Coupling buys rise time and nothing else: from 30.8 µs at k = 0.9 to 422 ns at 0.999, while the droop's time constant moves from 414 to 396 µs. The longest pulse that droops no more than 10%, over the rise, is 0.048 times the ratio of the upper band edge to the lower — the band ratio counted in rise times, 10.4 at k = 0.99 and 98.8 at 0.999. And the droop is not lost: a transformer has no gain at direct current, so the output swings below zero afterwards by exactly what the top lost, and the two areas match to 0.08%.
Named alongside it
The objects these essays reach for when they reach for this one.
Model rangeTransformerVolt-secondsCoupling coefficientSaturationFlux linkageInrush currentLeakage inductanceVolt-second limitBandwidthDesign tradeoffFlux density