Concept

Eddy current — where it appears

A current induced in a conducting material by the flux changing inside it, circulating in the material rather than in any winding. It dissipates as the square of the rate of change, so it grows as the square of frequency, and it is the mechanism that makes a measured core-loss frequency exponent exceed one.

Named by 3 essays across one field — each of them below, with the objects they name alongside it.

Alternating-current resistance against foil thickness, 4 layers. computed by solving, not by drawing. The falling dashed curve is the direct-current resistance, which is what more copper buys. The solid curve is the alternating-current resistance at 100 kHz for a portion of 4 layers, and it turns over: past ξ = 0.663 skin depths, thicker foil has MORE resistance, not less. The minimum sits at 1.3368 times the direct-current resistance of the same foil, which is four thirds and is the same number for every layer count above one. The resistance per turn there is 2.016 against √m = 2.000, which is the law the layer count obeys.

The copper that makes it worse

The rung below measured one conductor pushing its own current to its rim, and there is nothing to optimise in it: thicker wire is always less resistance. Stack the conductors and the quantity changes character. Each layer sits in the field of the ones below it, the loss that field drives has no upper bound in the thickness, and the product turns over — so a portion of four layers has a best foil thickness, and above it more copper is more resistance. The best thickness is the fourth root of three over the square root of the layer count, in skin depths, and the penalty at it is four thirds for every layer count above one.

magnetics · Winding
The Steinmetz exponent is a local slope, and how far it moves is a property of the material. computed by solving, not by drawing. Loss per cycle against peak flux density over three decades, marched on a play-operator core, with the local exponent d ln W / d ln B drawn across the top of the same frame. It is not a constant anywhere: 2.797 at 5.5 millitesla, heading for the three that Rayleigh's law gives, and 1.462 near saturation where the material has run out of magnetisation to give — a range of 1.420. How wide that range is is itself a property of the material: over the same amplitudes a soft core's exponent moves by 1.73 and a hard one's by 0.21. A single power law fitted across the whole range returns β = 2.518 and misses by 72.2 per cent; the same law fitted over the quarter of it from 9.7 to 24 millitesla returns 2.743 and misses by 0.97. Below 0.58 millitesla this discretisation has no loss at all, which is the finite operator count showing and not the material; the sweep starts above it.

The exponent nobody put in

A catalogue prints core loss as a coefficient times the frequency raised to one power and the flux to another, and the two exponents look like material constants. Neither is. On a loop built from play operators the frequency exponent is exactly one — a theorem, not a fit, because a rate-independent locus has the same area however fast it is traced — and the flux exponent is a local slope that runs from 2.94 at half a millitesla to 1.46 near saturation, so five windows on one measured curve give β from 1.58 to 2.84 and predictions three times apart at a hundred and fifty millitesla.

magnetics · Magnetic loss
The eddy term is f² below the skin-depth frequency and f^1.5 above it, both exactly. computed by solving, not by drawing. Eddy-current loss in a 0.35 millimetre lamination held at a mean flux of 1 tesla, against frequency, with the classical uniform-flux expression drawn beside it and the local exponent across the top. Below the frequency at which the sheet is two skin depths thick — 465 Hz here — the two agree and the exponent is 2.0000. Above it the flux is confined to a layer whose thickness falls as one over the square root of the frequency, and the exponent is 1.5000: three halves, exactly. It does not arrive there monotonically — it undershoots to 1.4847 at ξ = 3.28 and comes back up, which is the bounded cosine term the asymptotic statement drops. At 1.00 kHz the classical term is already 1.74 times the truth. The solve and the closed form agree to 7.5e-3 per cent across six decades.

The current inside the iron

Every core-loss law has an eddy term of the form d²f²B²/6ρ, and it is derived by assuming the flux is uniform across the lamination — an assumption that is a frequency and that the expression does not carry. Solved instead as a diffusion, the exponent is exactly 2 below the frequency at which the sheet is two skin depths thick, exactly 1.5 above it, and it undershoots to 1.485 on the way. For a 0.35 mm sheet the crossing is 465 hertz, so at a kilohertz the classical term is 1.74 times the truth and at ten kilohertz it is forty-seven times.

magnetics · Magnetic loss

Named alongside it

The objects these essays reach for when they reach for this one.

LaminationMagnetic lossModel rangeSkin effectSteinmetz equationAsymptotic approximationB h loopDesign tradeoffInterleavingMeasurement conditionPermeabilityPower law fit

All concepts