The copper that makes it worse
The rung below measured one conductor pushing its own current to its rim, and there is nothing to optimise in it: thicker wire is always less resistance. Stack the conductors and the quantity changes character. Each layer sits in the field of the ones below it, the loss that field drives has no upper bound in the thickness, and the product turns over — so a portion of four layers has a best foil thickness, and above it more copper is more resistance. The best thickness is the fourth root of three over the square root of the layer count, in skin depths, and the penalty at it is four thirds for every layer count above one.
The inductance that is a shape
Leakage inductance is the one transformer parameter that belongs to the geometry rather than to the material: twice the magnetic energy in the window under equal and opposite ampere-turns, divided by the square of the current. Solved as a field it is 3.086 microhenries a metre against a closed form's 3.128 when the copper fills the window, and 4.608 against 6.255 when it fills half of it. Interleaving is worth 3.11 times and not the four it is quoted as, and the missing 0.89 is the insulation nobody puts in the formula.