Encirclement count — where it appears

The number of times a loop gain's Nyquist locus wraps clockwise around the critical point −1 as frequency runs over the whole contour. It is obtained here as the accumulated turning of 1 + L rather than by counting axis crossings, so it needs no rule for which crossings matter. Added to the open-loop poles in the right half-plane it gives the number of unstable closed-loop poles.

Named by 2 essays across one field — each of them below, with the objects they name alongside it.

Also named here as nyquist criterion — the same set of essays touches all of them, so they are one junction rather than several.

Named alongside it

The objects these essays reach for when they reach for this one.

Loop gainNyquist criterionPhase marginStabilityGain marginLead compensationModel rangeNumerical errorVerification