Quadrature — where it appears
Named by 8 essays across 3 fields — each of them below, with the objects they name alongside it.
Two solves that add, and the one that does not
Every node voltage and every branch current in a linear network is the sum of the per-source solves, here to the last bit of a double at eighty-one settings. The power is not, and the gap is not a correction: two equal sources in antiphase put nothing at all into a load while adding their powers gives 222 milliwatts, and the sum is within one per cent of the truth only when one source is two hundred times the other.
Where the mechanisms are one mechanism
An amplifier is said to run out of three separate things — bandwidth, slew rate and rails — and errors from separate mechanisms add in quadrature while errors from one mechanism add as magnitudes. Measured as waveforms rather than as numbers, two of the three sit 18.4349 degrees apart, which is exactly the angle between a sinusoid and its own cube, and the third sits at ninety: its cosine against both of the others stays under 0.0025 wherever it exists. So the arithmetic is neither of the two anybody reaches for, and a budget built the right way is within 2.9 per cent where quadrature is 17 per cent low and a straight sum 37 per cent high.
The width no load can change
A switch's band was drawn against a load resistor and closed at 6.43 megahertz. Put a hold capacitor where the resistor was and the band changes axis and shape — a diagonal below 318 hertz, a floor of 495 picofarads above it — and stays exactly as wide: 1.8083 decades at 100 kilohertz for both loads, closing at 6.43 megahertz for both. Count the capacitor's error as a magnitude, as the resistor's always was, and the band appears to stay open to 91.6 megahertz. That extra room is 8.11 degrees of lag the count cannot see.
Where an open switch leaks to
A lone switch has a band whose width no load can change, because its open state leaks into the load. In a multiplexer the seven open channels leak into a node the selected channel holds, so the load leaves the answer and the source takes its place: one per cent of leak at 91.0 megahertz from buffered sources and 901 kilohertz from fifty ohms, moving as the first power of the tolerance rather than the second. Adding the channels' capacitance into one forty-picofarad switch puts it at 804 kilohertz, near the fifty-ohm figure by coincidence and a hundred and thirteen times low for a buffered one.
The capacitance a third switch moves
A changeover's open channel leaks into the source of the channel that is closed, so its isolation into fifty ohms falls from 643 megahertz with a buffered source to 6.34 megahertz with a fifty-ohm one. Put a third switch to ground between two series switches and the leak lands on half an ohm of closed switch instead: 814, 643 and 2,240 megahertz from sources of nothing, fifty ohms and a kilohm, rising forty decibels a decade where a changeover's rises twenty. The price is the shunt switch's own capacitance, moved under the closed path, which makes the T one per cent wrong as a waveform at 6.59 megahertz beside the changeover's 6.61.
The peak that only has a bound
Power does not superpose and the gap has a closed form — two times the real part of one current times the conjugate of the other, exact at every setting. A peak has nothing of the kind. A ten-volt fundamental with a third harmonic a third its size has one root-mean-square value, 7.454 volts at every relative phase because the two are orthogonal, and a peak running from 9.428 to 13.333 volts across the same sweep — reaching the sum of the two peaks exactly at 180 degrees, where the harmonic's own crest lands on the fundamental's, and having no closed form at all at the other end.
The cross terms that outnumber the sources
With two sources the power in a load has one cross term, and adding the separate powers is wrong by a factor of two. With thirty-two there are four hundred and ninety-six of them, and the factor is thirty-two: 940 milliwatts delivered against the 29.4 that adding gives. With the same thirty-two sources at seeded random phases it is 26.9 milliwatts — the sum itself, inside the standard error of sixty-four runs, because every cross term averages to nothing. One identity, two limits, and the two are a phased array's gain and a noise sum's.
The envelope that leaves early
A band-pass's group delay at its centre is the delay of an envelope, not of a carrier. Marched twice — on a sine and a cosine carrier, so the envelope is their modulus exactly — a 1 kHz burst through a band-pass of Q = 10 comes out 3.171 ms late against 2Q/ω₀ = 3.183, while the carrier's zero crossings come out within 6.4 µs of where they went in. Through a notch, whose group delay at its centre is −3.810 ms, the envelope peaks 3.746 ms before the input's. Neither is a paradox, and both hold only for bursts long against the inverse bandwidth: 60.6 per cent wrong at 0.6 of it, 0.7 per cent at 20.
Named alongside it
The objects these essays reach for when they reach for this one.
Model rangeDesign tradeoffSuperpositionLoadingOff isolationOn-resistanceParasiticsReal powerNonlinearitySource impedanceVerificationCrest factor