Off isolation — where it appears
Named by 8 essays across one field — each of them below, with the objects they name alongside it.
A band rather than an edge
Every other boundary in this collection is one-sided: a model is true below a frequency, or below an amplitude. A switch is a switch only for loads between 49.5 ohms and 1.01 megohms — bounded at both ends by the same part — and the upper end is a frequency as well as a resistance, so the band narrows as the frequency rises and shuts completely at 6.43 megahertz, above which no load resistance at all will do.
The width no load can change
A switch's band was drawn against a load resistor and closed at 6.43 megahertz. Put a hold capacitor where the resistor was and the band changes axis and shape — a diagonal below 318 hertz, a floor of 495 picofarads above it — and stays exactly as wide: 1.8083 decades at 100 kilohertz for both loads, closing at 6.43 megahertz for both. Count the capacitor's error as a magnitude, as the resistor's always was, and the band appears to stay open to 91.6 megahertz. That extra room is 8.11 degrees of lag the count cannot see.
Where an open switch leaks to
A lone switch has a band whose width no load can change, because its open state leaks into the load. In a multiplexer the seven open channels leak into a node the selected channel holds, so the load leaves the answer and the source takes its place: one per cent of leak at 91.0 megahertz from buffered sources and 901 kilohertz from fifty ohms, moving as the first power of the tolerance rather than the second. Adding the channels' capacitance into one forty-picofarad switch puts it at 804 kilohertz, near the fifty-ohm figure by coincidence and a hundred and thirteen times low for a buffered one.
The capacitance a third switch moves
A changeover's open channel leaks into the source of the channel that is closed, so its isolation into fifty ohms falls from 643 megahertz with a buffered source to 6.34 megahertz with a fifty-ohm one. Put a third switch to ground between two series switches and the leak lands on half an ohm of closed switch instead: 814, 643 and 2,240 megahertz from sources of nothing, fifty ohms and a kilohm, rising forty decibels a decade where a changeover's rises twenty. The price is the shunt switch's own capacitance, moved under the closed path, which makes the T one per cent wrong as a waveform at 6.59 megahertz beside the changeover's 6.61.
The floor below any load
A switch of half an ohm closed and a hundred megohms open is within one per cent of ideal for loads between two edges, and the edges close on each other as the tolerance tightens. At direct current they meet at 70.71 parts per million, into 7.07 kilohms: no load makes that switch better, which is 13.79 bits and a boundary with no frequency in it. A T of three such switches has no best load at all. Its error falls with the load towards five parts per billion — the square of the lone switch's resistance ratio rather than its root — and reaches ten only into two hundred megohms. Into the 7.07 kilohms that suited one switch, the T is worse than one switch.
The shunt switch the source sizes
A T is two series switches and a third to ground, and it is always drawn with three of the same part. The shunt switch pulls its own size two ways: larger, it holds the open node harder; larger, it hangs more capacitance on the closed path. The size at which the band closes latest is a balance of the two — the fourth root of 2/ε times √(Rₒₙ/(Rₛ + Rₒₙ)) — when the closed state is counted as an amplitude — 3.8 times a series switch from a buffered source, a third of one from fifty ohms, a twelfth from a kilohm — and it buys a band 3.4, 2.7 and 13 times wider. Counted as a waveform the root of ε goes, and from a buffered source the best shunt is exactly the series switch.
The resistance that bends the signal
A switch of half an ohm and a hundred megohms has a floor of 70.71 parts per million, 13.79 bits, because its on-resistance and its off-resistance cannot both be small beside one load. Most of that floor is a gain error, and a gain error calibrates away. Give the on-resistance a realistic ten per cent of movement across the signal range and the uncalibrated floor slips to 74.16 parts per million, while the part no calibration can touch — the curvature — balances the leak at 13.89 parts per million, 16.14 bits, into 1.39 kilohms. The floor was never set by the on-resistance. It is set by how much the on-resistance moves, as its square root.
The leak no switch can hold
A T of three switches reaches five parts per billion because its shunt switch holds the node a leak has to cross. A junction leakage does not cross anything: it flows out of the outer switch's terminal straight into the load. With 100 picoamperes of it at 25 °C, doubling every ten kelvin, the T's floor is 9.998 parts per million rather than five parts per billion — 16.61 bits, not 27.6 — and it has a best load again, at 100 kilohms. A lone switch loses nothing at room temperature. Above 91.4 °C, where the junction current reaches the off-resistance's conductance at one volt, the T is worse than one switch.
Named alongside it
The objects these essays reach for when they reach for this one.
Design tradeoffLoadingModel rangeOn-resistanceParasiticsQuadratureSource impedanceCrosstalkElectrical lengthLeakage currentLinearisationLumped-element