Real power — where it appears
Named by 15 essays across 3 fields — each of them below, with the objects they name alongside it.
The current that does no work
A solved network has been reporting its own real power on every page of this collection, as the second of the two checks each answer passes before it is drawn. What that check discards is the imaginary half — the power that flows out to a reactance and back again, does nothing, and is still carried by the cable, still heats the transformer, and is still on the bill.
The half that never arrives
Charging a capacitor from a step loses exactly as much energy as it stores, and the resistance it is lost in does not appear in the answer — the same 12.5 microjoules through ten ohms and through a hundred kilohms, to nine figures. Drive the same network with a ramp instead and the loss falls as two time constants over the ramp, with no floor beneath it at all.
The load that takes the most
A load equal to the source resistance takes more power than any other, and it does so at exactly fifty per cent efficiency — the source burns as much as the load receives. Ninety per cent efficiency needs a load nine times the source and delivers 36% of what was available, and a load half the source resistance delivers exactly as much as one twice it.
Two solves that add, and the one that does not
Every node voltage and every branch current in a linear network is the sum of the per-source solves, here to the last bit of a double at eighty-one settings. The power is not, and the gap is not a correction: two equal sources in antiphase put nothing at all into a load while adding their powers gives 222 milliwatts, and the sum is within one per cent of the truth only when one source is two hundred times the other.
What a meter multiplies by
An average-responding meter rectifies, averages and multiplies by 1.1107, which makes it exactly right for a sinusoid and wrong for everything else by the ratio of two form factors — 11.07 per cent high on a square wave and 35.9 per cent low on a rectifier drawing its current in sixty degrees. It is also exactly right at one other waveform, a 145.90 degree conduction angle, which is nobody's sinusoid. Beside it a true-RMS meter that reaches nine harmonics is two per cent low on a square wave and never within one per cent of anything narrower.
The half a switch keeps
Charging a capacitor from a step loses half the delivered energy whatever the resistance, and a ramp takes the loss down as 2τ/T with no floor. A staircase of N settled risers costs one Nth of the step, exact to four parts in a million, and the law ends at a dwell of 5.272 time constants. A switch is the other half of the same product and buys nothing at all: with the supply held at five volts and the channel conductance ramped over a thousand time constants, the loss is 1.00000000 of ½CV².
The peak that only has a bound
Power does not superpose and the gap has a closed form — two times the real part of one current times the conjugate of the other, exact at every setting. A peak has nothing of the kind. A ten-volt fundamental with a third harmonic a third its size has one root-mean-square value, 7.454 volts at every relative phase because the two are orthogonal, and a peak running from 9.428 to 13.333 volts across the same sweep — reaching the sum of the two peaks exactly at 180 degrees, where the harmonic's own crest lands on the fundamental's, and having no closed form at all at the other end.
The cross terms that outnumber the sources
With two sources the power in a load has one cross term, and adding the separate powers is wrong by a factor of two. With thirty-two there are four hundred and ninety-six of them, and the factor is thirty-two: 940 milliwatts delivered against the 29.4 that adding gives. With the same thirty-two sources at seeded random phases it is 26.9 milliwatts — the sum itself, inside the standard error of sixty-four runs, because every cross term averages to nothing. One identity, two limits, and the two are a phased array's gain and a noise sum's.
How many sources the cross terms count
N equal coherent sources on one load deliver N times the sum of their separate powers. Sources of unequal size deliver (Σ|a|)²/Σa² times it — solved on the network to ten figures — which is the number of equal sources that would carry the same penalty: a participation ratio. Amplitudes falling by 0.8 a source cap it at (1 + q)/(1 − q) = 9 however many there are; one large source and thirty-one at a tenth of its amplitude give 12.8, not 32, and for small sources the excess is 2(N − 1)ε — their amplitudes, not their powers, so thirty-one sources carrying a hundredth of the large one's power each turn 1.31 times its power into 16.8 times it when they line up. Random amplitudes take a fixed fraction off the count, (mean)²/(mean square): 0.75 for uniform ones. And with random phases none of it matters: the load takes the sum.
Sixty degrees, and the limit compensation stops raising
Series capacitors are put in transmission lines to raise how much power can pass between two sources before the angle between them runs out. The lossless textbook limit, V²/X(1 − k), rises without bound as the reactance is cancelled. With the line's resistance kept, the limit is V² cos β (1 − cos β)/R for an impedance angle β, and it peaks where β is exactly sixty degrees: 56.7 per cent cancellation and 264.5 kW on a 230 V tie of 0.05 + j0.2 Ω, against 194.4 uncompensated — then falls, to nothing at full cancellation. A line of R/X 0.1 can nearly triple its limit; one above 1/√3 cannot raise it at all. And at the best compensation the line delivers exactly half of what it is sent.
The reactance the capacitor cannot reach
A series capacitor raises a tie's transfer limit until the loop's impedance angle is sixty degrees, and on a bare 0.05 + j0.2 Ω line that is 56.7% cancellation. Put a machine at each end, its EMF held behind a reactance of its own, and the capacitor still cancels only the line: the sixty degrees now needs the line's reactance plus twice a machine's, less √3 times the resistance, as a fraction of the line's reactance, which passes 100% as soon as each machine's reactance exceeds √3/2 of the line's resistance — 0.043 Ω here. Beyond that the limit rises at every step to full cancellation, and the lossless estimate of the gain, wildly high on a bare line, becomes nearly right: 1.43 against 1.50 at 0.2 Ω. The higher limit is reached with the receiving terminal lower — 180 V falling to 148 at 0.1 Ω — and the capacitor's own resistance is negligible for any power capacitor: a Q of 222 keeps the peak within 1%.
The peak a sagging receiver keeps
The sixty degrees at which series compensation stops raising a tie's transfer limit is a statement about two ends at equal voltage. With the receiving end lower, the limit is a parabola in the cosine of the impedance angle whose top is at cos β = Vₛ/2Vᵣ: 56.3° and 62.6% cancellation for a receiver at 0.9 of the sender, 33.6° and 83.4% at 0.6, full cancellation at one half. But the height of that top is Vₛ²/4R whatever the receiving voltage — 264.5 kW for the 0.05 + j0.2 Ω tie from a receiver at 1.1 of the sender down to one at 0.5 — and at it the receiving end takes exactly half of what is sent, to four decimal places, for every receiving voltage tried. The best compensated tie is the sending source driving a matched load, and the receiving source's voltage only decides how much capacitor that takes.
The capacitor two-thirds of the way out
A feeder's reactive current costs loss in every section it passes through, and on a feeder whose load is spread along its length that current is largest at the substation and falls to nothing at the far end. Correcting it at the substation removes no loss at all. One phase of an 11 kV feeder carrying 2 MW at 0.8 lagging over ten kilometres loses 16.8 kW, of which 5.66 kW is the reactive current's; the best single capacitor is about two-thirds of the load's reactive power placed about two-thirds of the way out, and it removes 87.6% of that share — against the eight-ninths the textbook rule gives for an idealised line. Two capacitors at 2/5 and 4/5 remove 95.6%. The same capacitor left in at light load costs more than it saves below half load, and the rule for a continuous load is a statement about many taps.
The swing a diode keeps
Charging a capacitor through a resistor loses half the energy whatever the resistance, and putting an inductor in the path changes nothing: twenty-four settled charges from 10 µH to 10 mH and Q from 0.3 to 100 lose ½CV² to 1.4 parts in a hundred million. A diode that stops the current at its first zero changes everything. The capacitor keeps the overshoot, V(1 + d), the loss falls to ½CV²(1 − d²), and a charge of duration T costs π²/8 of what a ramp of the same duration costs.
The energy two capacitors cannot share
Join a charged capacitor to an empty one and the charge is shared exactly while the energy is not: the pair loses C₂/(C₁ + C₂) of what the first one held, through 1 Ω or 10 kΩ, with an inductor ringing for hundreds of cycles or without one. An inductor and a diode turn the sharing into an exchange — equal capacitors swap 96.9% of the energy at a loop Q of 50. And a charge pump is the sharing loss billed once a cycle: a doubler's efficiency is its output voltage over twice its input, to four parts in ten million, at every load and every clock.
Named alongside it
The objects these essays reach for when they reach for this one.
Design tradeoffModel rangeCharging exponentialEnergy-storageMaximum power transferPhasorSuperpositionVoltage regulationClosed formQuadratureReactanceReactive power