Concept

Rectification — where it appears

Passing an alternating current through elements that conduct one way, so that what comes out has a mean. In front of a reservoir capacitor it draws its charge in a short tall pulse rather than a sinusoid, which is why the current that sizes the transformer is several times the one the load draws.

Named by 4 essays across one field — each of them below, with the objects they name alongside it.

1000 µF across a 100 Ω load, rectified from 17 V peak. The output sits at 15.69 V with 1.331 V of ripple, against the 1.569 V the expression I/2fC gives — 15.1% high, because the capacitor is being recharged for part of the cycle rather than discharging throughout it. The lower panel is why: the diode conducts for 28.8° of each half cycle and carries 2.10 A at the peak, which is 13.4 times the 157 mA the load draws.

The direct voltage that is a sawtooth

A rectifier and a reservoir capacitor make what everybody calls a direct voltage. Marched with the diodes in the netlist, a thousand microfarads across a hundred ohms gives 15.69 volts with 1.33 volts of ripple on it, against the 1.57 the textbook expression predicts. The expression is high by the fraction of the cycle the diode conducts for — measured at 0.94 to 0.96 of it across two sweeps — and it has no opinion at all about the quantity that actually sizes the transformer, which is a peak diode current 13.4 times the current the load draws.

applied · Unregulated supply
The crest factor is 13.4 and the winding is sized by 3.01. computed by solving, not by drawing. Three ratios of the same settled march, against the reservoir. The crest factor — the peak diode current over the load's direct current — runs 6.43 to 24.25. The form factor, which is the root-mean-square current over the same direct current and is what a winding heats by, runs 2.114 to 4.077. Its square is the copper loss against a winding carrying the direct current alone, and that runs 4.47 to 16.62. The first ratio is 3.04 times the second at 220 µF and 5.95 times at 4700, so quoting one of them tells a reader nothing about the other.

The current that sizes the transformer

A reservoir's crest factor is 13.374 at a thousand microfarads and the winding is not sized by it. The root-mean-square of the same marched current is 3.0069 times the load's direct current, so the copper dissipates 9.0417 times what it would carrying the direct current alone — and the two ratios diverge, from 3.04 apart at 220 microfarads to 5.95 apart at 4700. The expression for the mean output is wrong in three places whose signs differ, and at 313.9 microfarads they cancel to six microvolts while the ripple expression inside it is still 32.3 per cent high.

applied · Unregulated supply
The series resistance that makes the ripple smaller. computed by solving, not by drawing, marched with the diodes in the netlist. A 1000 µF reservoir with 30 mΩ of its own series resistance. The resistance adds a step of ESR times the diode's peak current to the output and at the same time limits that peak current, and the two nearly cancel: the ripple has an interior minimum of 1.330 V at 17.0 mΩ, BELOW the 1.331 V a perfect capacitor gives, and rises to 1.711 V at an ohm. What the resistance buys monotonically is the peak current: the crest factor falls from 13.37 to 6.550 at an ohm, which more than halves the current that sizes the transformer, for 380 mV of mean output and a root-mean-square diode current that falls from 0.4717 A to 0.3484. The textbook ripple expression says 1.568 V here and moves by 2.4% across the whole axis, because it has no term for a series resistance at all.

The resistance that lowers the ripple

Two earlier essays here marched a reservoir with a perfect capacitor. A real one has tens of milliohms of its own, and the obvious expectation — that the resistive step it adds makes the ripple worse — is wrong in an interesting direction: the resistance also limits the charging current, and the ripple has an interior minimum of 1.3303 V at 17.0 mΩ, below the 1.3312 V a perfect capacitor gives. What the resistance buys monotonically is the peak current, which falls from 13.37 times the load's to 6.55 at an ohm, for 380 mV of mean output.

applied · Unregulated supply
The same 100 mΩ in the winding instead of the capacitor: 1.317 V of ripple against 1.335 V, at the same crest factor of 11.15. computed by solving, not by drawing, marched with the diodes in the netlist: a 1000 µF reservoir behind a centre-tapped rectifier, with a series resistance from 1 mΩ to 1 Ω placed either in the capacitor or in each half-winding. The crest factor is the same in both places to two parts in a thousand at every resistance — 13.34, 13.26, 13.03, 12.49, 11.15, 9.069, 6.548 — because both limit the charging current alike. The ripple is not: in the capacitor it has a minimum and rises to 1.711 V at an ohm; in the winding it falls throughout, to 1.172 V, against 1.331 V with no resistance. At an ohm the winding costs 534 mV of mean output and the capacitor 380 mV. The diode's root-mean-square current at an ohm is 0.3449 A with the resistance in the winding and 0.3484 A with it in the capacitor.

The resistance that belongs in the winding

A reservoir capacitor's series resistance lowers the ripple to a minimum of 1.3303 V at 17 mΩ and raises it past that. The same resistance moved into the transformer's winding limits the peak current by the same amount — the crest factor agrees to two parts in a thousand at every value from a milliohm to an ohm — and the minimum is gone: the ripple falls throughout, to 1.172 V at an ohm against 1.711 V in the capacitor. The two resistances each carry a current the other does not, and that one asymmetry decides where a deliberate one should go.

applied · Unregulated supply

Named alongside it

The objects these essays reach for when they reach for this one.

Conduction angleCrest factorReservoir capacitorDesign tradeoffEquivalent series resistanceTransformerCompanion modelForm factorMeasurement conditionModel rangePower factorTrue-RMS