The capacitor that is an inductor
A hundred-nanofarad capacitor follows 1/(2πfC) for four decades and then turns round and climbs. Above 14.5 MHz it is an inductor, and a decade past that its impedance is ninety-nine times what its capacitance predicts — all of it caused by about a nanohenry of lead and via that nobody chose and nobody drew.
The pair that is worse than either
A bulk capacitor and a ceramic are fitted together because each is good where the other is not, and between them is a frequency at which the pair presents six times the impedance either one does alone. The peak is a parallel resonance between one part's inductance and the other's capacitance, its height is one over the series resistance every data sheet asks to be minimised, and at it the two capacitors exchange 5.87 amps for every amp the load draws.
The capacitor that is not where the load is
A decoupling bank is usually drawn as two capacitors joined to a load through nothing, which is a stated simplification. Put three nanohenries of ordinary copper in — one of mounting loop per part and two of plane between the bank and the load — and the anti-resonance moves down to 5.63 megahertz and up to 1.29 ohms, a probe touching the ceramic reads a twelfth of what the load sees at 16.7 megahertz and three and a half times too much at 8.35, and the twentieth capacitor is worse than the second.
The floor and the ceiling move apart
A decoupling bank is judged by two numbers — the lowest impedance it reaches and the highest frequency at which it still meets its target — and with no copper between the parts and the load both improve together as capacitors are added, 5.000 milliohms down to 1.500 and 19.8 megahertz up to 162. Three nanohenries of ordinary board separate them. The bank's own floor still falls 3.33 times while the load's falls 1.49, and the ceiling read at the parts climbs to 82.4 megahertz while the load's peaks at 8.06 and falls to 5.05. At twenty parts the two nodes disagree by a factor of 94 about the same solve.
The floor every filter has
The elliptic design was refused because its equiripple stopband is a floor and no sample rate reaches past a floor, while an all-pole design falls at six decibels an octave per pole for ever — so a faster clock is always an answer for one and never for the other. On paper. Ten femtofarads of stray capacitance from a filter's input to its output, which is a fraction of a picofarad between two tracks, puts the eighth-order Butterworth's stopband at −120 decibels from 136 kilohertz onwards where its poles predict −293. Every all-pole design has a floor, and it is a layout rather than a design.
The peak a load step does not see
A decoupling bank is specified by its impedance against frequency, and the number that fails a target is the anti-resonance peak — 0.966 Ω at 7.12 MHz for the bulk-and-ceramic pair standing on a regulator. A load that steps by one ampere moves that supply by 132 mV, 14% of what the peak suggests: a step rings the resonance once, and its first swing is set by the resonance's characteristic impedance √(L/C) = 0.224 Ω, not by its Q. The peak is the voltage per ampere of a load that sits at the resonance; switched at 7.12 MHz the same load builds over six cycles to ±611 mV, the peak times the current's fundamental. So damping, the cure for the peak, is a cure for that load only: sixteen times the ESR cuts the peak 8.9-fold and leaves a step's swing between 120 and 155 mV. What decides a step is its edge — 132 mV for anything faster than a few nanoseconds, 28 mV for a microsecond.
Named alongside it
The objects these essays reach for when they reach for this one.
DecouplingParasiticsSelf-resonanceEquivalent series resistanceMeasurement conditionQuality factorDamping ratioImpedance matchingLoop areaResonanceAnti-alias filterCommon-impedance