Concept

Equivalent series inductance — where it appears

The inductance in series with a capacitor's capacitance, from its leads, terminals and internal structure. It sets the frequency above which the part is an inductor rather than a capacitor, and in a bank of several parts it is what resonates with a neighbour's capacitance.

Named by 6 essays across 3 fields — each of them below, with the objects they name alongside it.

A 100 nF capacitor, and what it is above 14.5 MHz. The dashed line is 1/(ωC), which is what the symbol means. The solid line is the same part with 30 mΩ of series resistance and 1.2 nH of series inductance, solved. They part company at 4.69 MHz and by a decade above resonance the part's impedance is 99.0× what its capacitance predicts.

The capacitor that is an inductor

A hundred-nanofarad capacitor follows 1/(2πfC) for four decades and then turns round and climbs. Above 14.5 MHz it is an inductor, and a decade past that its impedance is ninety-nine times what its capacitance predicts — all of it caused by about a nanohenry of lead and via that nobody chose and nobody drew.

frequency · Real capacitor
A bulk capacitor and a ceramic, and the peak between them at 6.52 MHz. computed by solving, not by drawing. Each capacitor is three elements — its capacitance, its series resistance and its series inductance — and a one-amp source drives the node, so the node voltage is the impedance. Alone, each dips to its own series resistance at its own self-resonance and rises on either side. Together they do not: between the two resonances the bulk part is an inductor and the ceramic is still a capacitor, and an inductance across a capacitance is a parallel resonance. The pair reaches 1.187 Ω at 6.52 MHz, where the bulk alone would give 0.2023 Ω and the ceramic alone 0.2055 — 5.87 times worse than either. The dashed curves are the two parts on their own; the solid one is what the load actually sees.

The pair that is worse than either

A bulk capacitor and a ceramic are fitted together because each is good where the other is not, and between them is a frequency at which the pair presents six times the impedance either one does alone. The peak is a parallel resonance between one part's inductance and the other's capacitance, its height is one over the series resistance every data sheet asks to be minimised, and at it the two capacitors exchange 5.87 amps for every amp the load draws.

power · Decoupling
Three nanohenries of copper move the peak to 5.63 MHz and raise it to 1.29 Ω. computed by solving, not by drawing. The same two capacitors, with and without the inductance of the way to them: one nanohenry of mounting loop per part and two nanohenries of plane between the bank and the load. The dashed curve is the bank with no inductance in the way, peaking at 1.187 Ω at 6.52 MHz; the solid one is what the load sees, peaking at 1.293 Ω at 5.63 MHz. The peak moves down because the branch that is inductive at that frequency got more inductive, and it rises for the same reason. Above about twenty megahertz the two part company entirely: the bank is still falling toward its parts' own resistances and the load is rising on two nanohenries that no capacitor is across.

The capacitor that is not where the load is

A decoupling bank is usually drawn as two capacitors joined to a load through nothing, which is a stated simplification. Put three nanohenries of ordinary copper in — one of mounting loop per part and two of plane between the bank and the load — and the anti-resonance moves down to 5.63 megahertz and up to 1.29 ohms, a probe touching the ceramic reads a twelfth of what the load sees at 16.7 megahertz and three and a half times too much at 8.35, and the twentieth capacitor is worse than the second.

power · Decoupling
The bank reaches 1.500 mΩ and the load sees 141.5 mΩ at that same frequency. computed by solving, not by drawing. One bulk part and 20 ceramics, with a nanohenry of mounting loop each and two nanohenries of plane between the bank and the load, solved once per frequency and read at both nodes. The dashed curve is the bank's own node — what a probe on the parts measures. The solid one is the load. The bank's least impedance is 1.500 mΩ at 11.3 MHz, and at that frequency the load sees 141.5 mΩ, which is 94.3 times more, against 141.5 mΩ of plane reactance at that frequency. Whatever the parts do, the load's reading cannot fall below the reactance of the copper in front of them, and the parts reach their best by moving up the frequency axis into it.

The floor and the ceiling move apart

A decoupling bank is judged by two numbers — the lowest impedance it reaches and the highest frequency at which it still meets its target — and with no copper between the parts and the load both improve together as capacitors are added, 5.000 milliohms down to 1.500 and 19.8 megahertz up to 162. Three nanohenries of ordinary board separate them. The bank's own floor still falls 3.33 times while the load's falls 1.49, and the ceiling read at the parts climbs to 82.4 megahertz while the load's peaks at 8.06 and falls to 5.05. At twenty parts the two nodes disagree by a factor of 94 about the same solve.

power · Decoupling
An all-pole filter's stopband floor: -120 dB, from 10 fF nobody drew. computed by solving, not by drawing. A butterworth 8 realised at a 20 kHz passband, drawn twice: from its poles, which fall at 48 decibels an octave for ever, and from the same netlist with 10 femtofarads of stray capacitance from its input to its last shunt node — a fraction of a picofarad between two tracks. The second stops falling at -120.0 dB at 136 kHz, because the stray bypasses every pole in front of it and what is left is its ratio to the shunt capacitance it divides against. The poles alone predict -293 dB a decade further out, which is 173 decibels lower. So an all-pole design has a stopband floor exactly as an elliptic one does — -140 dB at 1 fF, -130 dB at 3 fF, -120 dB at 10 fF, -110 dB at 30 fF, -100 dB at 100 fF, which is 20.0 decibels per decade of stray — and above that frequency a faster sample rate buys nothing at all, which is the refusal recorded for the elliptic row and not for this one.

The floor every filter has

The elliptic design was refused because its equiripple stopband is a floor and no sample rate reaches past a floor, while an all-pole design falls at six decibels an octave per pole for ever — so a faster clock is always an answer for one and never for the other. On paper. Ten femtofarads of stray capacitance from a filter's input to its output, which is a fraction of a picofarad between two tracks, puts the eighth-order Butterworth's stopband at −120 decibels from 136 kilohertz onwards where its poles predict −293. Every all-pole design has a floor, and it is a layout rather than a design.

digital · Anti-alias
The bank's impedance peaks at 0.966 Ω at 7.12 MHz; a one-ampere load step moves the supply by 132.4 mV. computed by solving, not by drawing. The bulk-and-ceramic pair of the decoupling essays — 10 µF with 5 mΩ and 5 nH, 100 nF with 30 mΩ and 1 nH — standing on a regulator of 2 mΩ and 20 nH, and the voltage at the bank when the load's current steps by one ampere, from the impedance's own step response by residues (solid). The impedance this bank presents peaks at 0.966 Ω at 7.12 MHz (upper line), the parallel resonance of the bulk part's inductance with the ceramic. The step rings at that frequency and its largest swing is 132.4 mV, 31.3 ns after the step — about a quarter period — which is 14% of the peak and 59% of the resonance's characteristic impedance √(L/C) = 0.224 Ω (lower line).

The peak a load step does not see

A decoupling bank is specified by its impedance against frequency, and the number that fails a target is the anti-resonance peak — 0.966 Ω at 7.12 MHz for the bulk-and-ceramic pair standing on a regulator. A load that steps by one ampere moves that supply by 132 mV, 14% of what the peak suggests: a step rings the resonance once, and its first swing is set by the resonance's characteristic impedance √(L/C) = 0.224 Ω, not by its Q. The peak is the voltage per ampere of a load that sits at the resonance; switched at 7.12 MHz the same load builds over six cycles to ±611 mV, the peak times the current's fundamental. So damping, the cure for the peak, is a cure for that load only: sixteen times the ESR cuts the peak 8.9-fold and leaves a step's swing between 120 and 155 mV. What decides a step is its edge — 132 mV for anything faster than a few nanoseconds, 28 mV for a microsecond.

power · Decoupling

Named alongside it

The objects these essays reach for when they reach for this one.

DecouplingParasiticsSelf-resonanceEquivalent series resistanceMeasurement conditionQuality factorDamping ratioImpedance matchingLoop areaResonanceAnti-alias filterCommon-impedance

All concepts