Concept

Equivalent series inductance — where it appears

The inductance in series with a capacitor's capacitance, from its leads, terminals and internal structure. It sets the frequency above which the part is an inductor rather than a capacitor, and in a bank of several parts it is what resonates with a neighbour's capacitance.

Named by 4 essays across 2 fields — each of them below, with the objects they name alongside it.

A 100 nF capacitor, and what it is above 14.5 MHz. The dashed line is 1/(ωC), which is what the symbol means. The solid line is the same part with 30 mΩ of series resistance and 1.2 nH of series inductance, solved. They part company at 4.69 MHz and by a decade above resonance the part's impedance is 99.0× what its capacitance predicts.

The capacitor that is an inductor

A hundred-nanofarad capacitor follows 1/(2πfC) for four decades and then turns round and climbs. Above 14.5 MHz it is an inductor, and a decade past that its impedance is ninety-nine times what its capacitance predicts — all of it caused by about a nanohenry of lead and via that nobody chose and nobody drew.

frequency · Real capacitor
A bulk capacitor and a ceramic, and the peak between them at 6.52 MHz. computed by solving, not by drawing. Each capacitor is three elements — its capacitance, its series resistance and its series inductance — and a one-amp source drives the node, so the node voltage is the impedance. Alone, each dips to its own series resistance at its own self-resonance and rises on either side. Together they do not: between the two resonances the bulk part is an inductor and the ceramic is still a capacitor, and an inductance across a capacitance is a parallel resonance. The pair reaches 1.187 Ω at 6.52 MHz, where the bulk alone would give 0.2023 Ω and the ceramic alone 0.2055 — 5.87 times worse than either. The dashed curves are the two parts on their own; the solid one is what the load actually sees.

The pair that is worse than either

A bulk capacitor and a ceramic are fitted together because each is good where the other is not, and between them is a frequency at which the pair presents six times the impedance either one does alone. The peak is a parallel resonance between one part's inductance and the other's capacitance, its height is one over the series resistance every data sheet asks to be minimised, and at it the two capacitors exchange 5.87 amps for every amp the load draws.

power · Decoupling
Three nanohenries of copper move the peak to 5.63 MHz and raise it to 1.29 Ω. computed by solving, not by drawing. The same two capacitors, with and without the inductance of the way to them: one nanohenry of mounting loop per part and two nanohenries of plane between the bank and the load. The dashed curve is the bank as the rung below drew it, peaking at 1.187 Ω at 6.52 MHz; the solid one is what the load sees, peaking at 1.293 Ω at 5.63 MHz. The peak moves down because the branch that is inductive at that frequency got more inductive, and it rises for the same reason. Above about twenty megahertz the two part company entirely: the bank is still falling toward its parts' own resistances and the load is rising on two nanohenries that no capacitor is across.

The capacitor that is not where the load is

The rung below this one connects two capacitors to a load through nothing, and says so. Put three nanohenries of ordinary copper in — one of mounting loop per part and two of plane between the bank and the load — and the anti-resonance moves down to 5.63 megahertz and up to 1.29 ohms, a probe touching the ceramic reads a twelfth of what the load sees at 16.7 megahertz and three and a half times too much at 8.35, and the twentieth capacitor is worse than the second.

power · Decoupling
The bank reaches 1.500 mΩ and the load sees 141.5 mΩ at that same frequency. computed by solving, not by drawing. One bulk part and 20 ceramics, with a nanohenry of mounting loop each and two nanohenries of plane between the bank and the load, solved once per frequency and read at both nodes. The dashed curve is the bank's own node — what a probe on the parts measures. The solid one is the load. The bank's least impedance is 1.500 mΩ at 11.3 MHz, and at that frequency the load sees 141.5 mΩ, which is 94.3 times more, against 141.5 mΩ of plane reactance at that frequency. Whatever the parts do, the load's reading cannot fall below the reactance of the copper in front of them, and the parts reach their best by moving up the frequency axis into it.

The floor and the ceiling move apart

A decoupling bank is judged by two numbers — the lowest impedance it reaches and the highest frequency at which it still meets its target — and with no copper between the parts and the load both improve together as capacitors are added, 5.000 milliohms down to 1.500 and 19.8 megahertz up to 162. Three nanohenries of ordinary board separate them. The bank's own floor still falls 3.33 times while the load's falls 1.49, and the ceiling read at the parts climbs to 82.4 megahertz while the load's peaks at 8.06 and falls to 5.05. At twenty parts the two nodes disagree by a factor of 94 about the same solve.

power · Decoupling

Named alongside it

The objects these essays reach for when they reach for this one.

DecouplingSelf-resonanceParasiticsEquivalent series resistanceImpedance matchingLoop areaMeasurement conditionQuality factorCommon-impedanceDamping ratioLead inductanceResonance

All concepts