Fringing field — where it appears
Named by 4 essays across 2 fields — each of them below, with the objects they name alongside it.
The edges that are lengths
Almost every boundary in this collection is a frequency or an amplitude, and both of those are things a circuit designer chooses. A handful are lengths — the 0.60 millimetres a gap's field reaches into a window, the 200 microns between a track and its plane, the 10 centimetres at which Kirchhoff's laws are a degree out — and they behave differently in one way that matters: nobody chooses them at the schematic, they are set by whoever builds the thing, and they appear in no netlist at all.
The turns nearest the gap
A gapped inductor's flux does not turn a corner into the iron on its way out of the gap; it bulges into the window and crosses the copper at right angles to the layers. Four tenths of a millimetre from a one-millimetre gap, the worst turn of an eight-turn winding dissipates 37.5 times its direct-current loss and the winding as a whole 14.1 times. Move the same winding three millimetres further out and those become 2.9 and 2.4 — and the distance that governs it is 0.60 millimetres, which is not the gap length and does not scale with it.
The gap that is bigger than it is
A magnetic circuit prices a gap as g/µ₀A and everybody knows that is low, because the flux bulges out of the sides. The usual repair — add one gap length to each dimension of the gap's area — supplies half the correction at a 0.3 mm gap and 85 per cent at 1.7 mm, on a correction worth 10 per cent of the inductance at the first and 33 at the second. It is not a rule that is right or wrong; it is a rule whose accuracy is a function of the very thing it is correcting.
The gap that is three gaps
Reluctances in series add, so one gap of 1.2 millimetres and three of 0.4 are the same magnetic circuit: the same inductance, the same saturation current, the same energy in the air. They are not the same field. Solved in two dimensions, the winding beside the single gap dissipates 6.52 times its direct-current loss and its worst turn 13.3; beside three gaps those are 3.00 and 3.7. And there is a best number of gaps rather than a monotone gain — past three, spreading them along the leg brings each one close to a different part of the winding.
Named alongside it
The objects these essays reach for when they reach for this one.
Air gapDesign tradeoffField solutionMagnetic pathModel rangeProximity effectEnergy-storageHot spotReluctanceClosed formLumped-elementMeasurement condition