Field solution — where it appears
Named by 9 essays across one field — each of them below, with the objects they name alongside it.
The assumption that is a geometry
Every alternating-resistance number this collection has computed for a winding rests on one sentence — the field is parallel to the layers everywhere — and the sentence has never been tested, because testing it needs a field. Solved as one, a portion of foils that fills its window returns Dowell's expression to 0.155 per cent; the same copper filling a quarter of it returns 9.00 against the expression's 16.38, and dissipates 0.528 watts a metre against 0.232. The ratio falls by 45 per cent and the loss more than doubles.
The turns nearest the gap
A gapped inductor's flux does not turn a corner into the iron on its way out of the gap; it bulges into the window and crosses the copper at right angles to the layers. Four tenths of a millimetre from a one-millimetre gap, the worst turn of an eight-turn winding dissipates 37.5 times its direct-current loss and the winding as a whole 14.1 times. Move the same winding three millimetres further out and those become 2.9 and 2.4 — and the distance that governs it is 0.60 millimetres, which is not the gap length and does not scale with it.
The wire that is not a foil
Almost no winding is made of foil, and the closed form for a winding's alternating-current resistance is about foils. The bridge between them is a substitution — squeeze the layer's conductors together, spread the result back across the breadth, divide the conductivity by the porosity — and it replaces a two-dimensional geometry with a one-dimensional one. Solved as a field it is exact where it must be, at a porosity of one, and 7.2 per cent high at a porosity of 0.40. It errs on the safe side, which is the half of the answer nobody could have assumed.
The gap that is bigger than it is
A magnetic circuit prices a gap as g/µ₀A and everybody knows that is low, because the flux bulges out of the sides. The usual repair — add one gap length to each dimension of the gap's area — supplies half the correction at a 0.3 mm gap and 85 per cent at 1.7 mm, on a correction worth 10 per cent of the inductance at the first and 33 at the second. It is not a rule that is right or wrong; it is a rule whose accuracy is a function of the very thing it is correcting.
The inductance that is a shape
Leakage inductance is the one transformer parameter that belongs to the geometry rather than to the material: twice the magnetic energy in the window under equal and opposite ampere-turns, divided by the square of the current. Solved as a field it is 3.086 microhenries a metre against a closed form's 3.128 when the copper fills the window, and 4.608 against 6.255 when it fills half of it. Interleaving is worth 3.11 times and not the four it is quoted as, and the missing 0.89 is the insulation nobody puts in the formula.
The optimum that does not move
A foil winding has a best thickness — past it, more copper is more resistance — and at that thickness the alternating-current resistance is four thirds of the direct-current resistance, whatever the layer count. Both of those are one-dimensional results, and this ladder has spent three rungs finding that the one-dimensional picture is 82 per cent wrong about the resistance ratio. Solved as a field, the optimum drifts by 8.3 per cent between a full window and a quarter-full one, and four thirds becomes 1.34, 1.35, 1.41. The trade barely moves while everything it is made of moves a great deal.
The gap that is three gaps
Reluctances in series add, so one gap of 1.2 millimetres and three of 0.4 are the same magnetic circuit: the same inductance, the same saturation current, the same energy in the air. They are not the same field. Solved in two dimensions, the winding beside the single gap dissipates 6.52 times its direct-current loss and its worst turn 13.3; beside three gaps those are 3.00 and 3.7. And there is a best number of gaps rather than a monotone gain — past three, spreading them along the leg brings each one close to a different part of the winding.
The other half of the same window
The two-dimensional solve that settled what a winding's alternating-current resistance really is computed one of the window's two parameters and never mentioned the other. Read with Laplace instead of the vector potential, the same cross-section returns 926.9 picofarads a metre — and 89 per cent of that energy sits inside films that occupy 14.1 per cent of the window. The instrument agrees with a layered slab to three parts in ten thousand billion and converges on a real winding at order 1.34, and the reason for the shortfall is not the arithmetic but the corner of a conductor.
Interleaving is a choice, not an improvement
Splitting a transformer's windings into six sections divides its leakage inductance by 21.4 and multiplies its winding-to-winding capacitance by 11.0. The product of the two — which is what sets the frequency the part stops being a transformer at — moves by 1.94, and the resonance it decides goes from 1.804 to 2.515 megahertz for all that work. What interleaving really changes is the winding's characteristic impedance, 95.2 ohms down to 6.2, and nobody quotes it.
Named alongside it
The objects these essays reach for when they reach for this one.
Design tradeoffModel rangeEnergy-storageProximity effectWindingClosed formVerificationAir gapFringing fieldLeakage inductanceMagnetic pathSkin effect