Inrush current — where it appears
Named by 6 essays across 2 fields — each of them below, with the objects they name alongside it.
The first cycle, which no steady state contains
Every number this field computes about a rectifier — the ripple, the crest factor, the conduction angle, the power factor — is read from the settled state, and the march that produces them starts from an empty capacitor and throws the first cycle away. That first conduction carries 32.4 amperes against a repetitive peak of 1.23, it is 26 times larger than anything the circuit ever does again, and how large it is depends on when somebody's hand closed the switch.
The inductance that limits, and lifts
Adding winding resistance to a rectifier limits the first peak and does not reduce the energy at all — the essay below measured ∫i²dt as two per cent apart over a factor of four in the resistance. Adding leakage inductance does both: it divides the peak by seven and the energy by five, and dissipates nothing to do it. What it buys instead is a rectifier whose output sits 29 per cent above the peak of its own supply, permanently, which every steady-state expression in this field says cannot happen.
The protection that is gone by the second time
An inrush thermistor is ten ohms cold and holds the first cycle down; then the load current warms it and it settles at 83 degrees and 1.94 ohms, which is 19 per cent of what was bought. That is the design working. It is also a part that takes 198 seconds to recover half its cold resistance, against a reservoir capacitor that empties in tens of milliseconds — so a mains dip in that window hands the rectifier an unlimited inrush into an empty capacitor, which is the exact event the part is on the bill of materials for.
The walk that stops
A drive whose two half-cycles differ in volt-seconds walks the flux to saturation in a count of cycles, and the essay that measured it concluded that no amplitude puts the design inside a limit. That model has a stiff source and a winding of no resistance. With resistance in the loop the walk has a fixed point, held by an identity the material is not in — the mean magnetising current is the drive's direct component divided by the resistance, to seven parts in 10¹³ — and the boundary becomes a resistance rather than a time: 0.1014 ohms bisected, at a one per cent imbalance and half the volt-second limit.
The instant a transformer is worst at
A capacitor-input rectifier draws its worst inrush when it is switched on at the peak of the mains. A transformer's own magnetising branch is the other way round: switched on at the voltage zero, a 230 V primary worked at 1.4 T draws 87.6 A in its first half-cycle, 791 times its settled magnetising current, and at the voltage peak it draws nothing extra at all. The core's flux has to start from zero, the voltage does not, and how close the working flux sits to half of saturation decides the size.
The harmonic that names an inrush
A transformer's differential relay sees an inrush as current going in and nothing coming out, which is what an internal fault looks like, and it tells them apart by the second harmonic. Marched cycle by cycle, an inrush starts at 79% second harmonic and stays above the usual 15% restraint for thirty cycles — long after its current has fallen from 88 A to 205 mA, because the current unwinds in a few cycles and the flux offset under it takes seconds. A fault's offset is a smooth exponential and peaks at 14.6% only when X/R is as low as three.
Named alongside it
The objects these essays reach for when they reach for this one.
Model rangeFlux linkageMagnetising inductanceReservoir capacitorSaturationTransient responseVolt-secondsCrest factorFixed pointMarchingRectifierDamping ratio