A boundary in volt-seconds
A core saturates on the integral of the voltage applied to it, not on the current through it and not at a frequency. The quantity that belongs to the core is N·Ae·Bsat — 3.500 mWb-turn here — and it has no frequency in it at all. Everything a data sheet says about a transformer's frequency rating is that one number divided by 2πf once: measured on a marched flux, the voltage a winding may carry is proportional to frequency to a fitted exponent of 1.000000.
The flux that walks
The previous essay's saturation limit is an amplitude, and an amplitude can be respected. This one cannot. A drive whose two half-cycles differ in volt-seconds by one per cent adds the same small area to the flux every cycle, so it reaches saturation after 64 cycles — and halving the drive gives 128, and a tenth of it gives 637. Reducing the amplitude buys time in exact proportion and removes nothing. There is no amplitude at which the design is inside a limit.
The delay that is two delays
Modelling one comparator delay applied to both transitions makes the two half cycles equal by construction, and the fix is a change of one line. Made, the duty cycle moves by 0.28 per cent for twenty nanoseconds of skew rather than the 0.40 the obvious expression gives, more hysteresis improves the duty cycle and worsens the volt-seconds at the same time, and ten nanoseconds of skew saturates a hundred-turn core in 231 cycles.
The duty cycle that costs nothing
A converter drives its core with a rectangular voltage, so the flux is a triangle whose two slopes differ by nineteen to one at a five per cent duty. The play-operator core charges exactly the same for all of them — 2.1006 joules per cubic metre at every duty and for a sinusoid of the same peak, to three parts in ten thousand — because a rate-independent locus depends on where the flux went and not on how fast. Real cores charge tens of per cent more, and the standard correction hides its entire waveform dependence in α − 1, which is the one term a rate-independent model has none of.
Two inductances at one current
A data sheet prints one L(i) curve and there are two. An operator sitting inside its own backlash contributes nothing to dB/dH, so a small excitation sees only the operators still moving — every one at the tip of a loop, none just after a reversal — and the same core at zero bias measures 14.90 millihenries pushed downward and 8.30 pushed upward, a factor of 1.80. The same split decides what a converter's ripple costs: held at the flux swing volt-seconds actually fix, a twenty-millitesla ripple costs twelve times more at a hundred and seventy-five amperes per metre of bias than at none, and above a hundred and eighty-three the question has no answer at all.
The walk the core sees
Threshold noise in a relaxation oscillator walks its timing at 3.77 nanoseconds per root period at β = 0.5, because the draw two half cycles share adds. A transformer driven by the same square wave sees the difference of the halves instead, where the shared draw subtracts, and that walks at 1.89 — exactly β times the timing, 18.3 ns against 35.9 after a hundred periods over six hundred seeded runs. The per-period duty error does not vanish with the hysteresis and the walk does, consecutive duty errors are anticorrelated where consecutive periods are not, a comparator skew outruns the walk after 2(σB/d)² periods, and at a fixed frequency the core wants less hysteresis than the clock does.
The spread a winding resistance holds
A relaxation oscillator's threshold noise walks an ideal core's flux without limit. Put the winding's resistance back and the walk stops at a spread: 1.22% of a half cycle's swing when L/R is a hundred periods, growing as the square root of L/R, while a comparator skew's offset grows as L/R itself. The anticorrelation between consecutive duty errors is worth 24% of that spread at β = 0.5 and 62% at β = 0.2 — but only in a core slow enough to remember several periods. And the resistance that bounds the walk is a boundary in its own right: with a millihenry and a fifth of the swing to spare, an ohm tolerates 12.9 mV of noise, and a hundred picoseconds of skew needs at least 0.14 Ω.
The count a core survives
A relaxation oscillator with a 300 ps comparator skew and 5 mV of threshold noise saturates an ideal core with 100 ns of volt-second headroom after 502 periods on average — the 500 the skew alone gives — and one drive in a hundred by 184. The mean does not see the noise at all until the noise is large enough to saturate the core the other way first; the early tail sees nothing else. Every skew and noise level falls on one curve in one ratio, the skew's count over the count at which its ramp overtakes the walk. Read as a burst, a thousand periods with one failure in a thousand allows 150 ps of skew with no noise, 93.5 ps at a millivolt, and none at all above 2.41 mV.
The ring a blocking capacitor buys
A series capacitor in front of a transformer stops its flux from walking: a 55%-duty drive that walks a bare core by 0.40 units of volt-time a period settles within a few dozen periods once the capacitor takes the drive's average. The price is a second-order high-pass with the magnetising inductance, and an inductance lets its poles go complex where two resistive coupling stages never could. Between equal resistances the damping cannot fall below 1/√2, and the poles are complex only for a capacitor between 0.17 and 5.8 times L/R². From a stiff driver the damping is √(L/C)/2R and has no floor: a capacitor large enough to make the droop small — the droop is 1/RC, the capacitor's and not the transformer's — makes the tail ring, from one zero crossing at a tenth of L/R² to thirty-five at a hundred.
The walk that stops
A drive whose two half-cycles differ in volt-seconds walks the flux to saturation in a count of cycles, and the essay that measured it concluded that no amplitude puts the design inside a limit. That model has a stiff source and a winding of no resistance. With resistance in the loop the walk has a fixed point, held by an identity the material is not in — the mean magnetising current is the drive's direct component divided by the resistance, to seven parts in 10¹³ — and the boundary becomes a resistance rather than a time: 0.1014 ohms bisected, at a one per cent imbalance and half the volt-second limit.
The instant a transformer is worst at
A capacitor-input rectifier draws its worst inrush when it is switched on at the peak of the mains. A transformer's own magnetising branch is the other way round: switched on at the voltage zero, a 230 V primary worked at 1.4 T draws 87.6 A in its first half-cycle, 791 times its settled magnetising current, and at the voltage peak it draws nothing extra at all. The core's flux has to start from zero, the voltage does not, and how close the working flux sits to half of saturation decides the size.
The harmonic that names an inrush
A transformer's differential relay sees an inrush as current going in and nothing coming out, which is what an internal fault looks like, and it tells them apart by the second harmonic. Marched cycle by cycle, an inrush starts at 79% second harmonic and stays above the usual 15% restraint for thirty cycles — long after its current has fallen from 88 A to 205 mA, because the current unwinds in a few cycles and the flux offset under it takes seconds. A fault's offset is a smooth exponential and peaks at 14.6% only when X/R is as low as three.
Every draw shared, and nothing in common
A relaxation oscillator's period error and its volt-second error are made of the same threshold draws, and they are exactly uncorrelated. A period weighs its three draws A, A + B and B; the high half less the low weighs the same three A, B − A and −B; the products sum to A² + B² − A² − B², which is zero at every hysteresis. Over forty thousand periods the measured correlation is 0.008 against a resolution of 0.010. What the two do share is one draw with the period on either side, ±0.157 at β = 0.5, and over any whole burst those two lags cancel term for term. Four thousand bursts judged against twenty-five pairs of limits fail both ways exactly as often as the product of the two rates says: the margins specified separately double-count nothing.