Flux density — where it appears
Named by 4 essays across 2 fields — each of them below, with the objects they name alongside it.
A boundary in volt-seconds
A core saturates on the integral of the voltage applied to it, not on the current through it and not at a frequency. The quantity that belongs to the core is N·Ae·Bsat — 3.500 mWb-turn here — and it has no frequency in it at all. Everything a data sheet says about a transformer's frequency rating is that one number divided by 2πf once: measured on a marched flux, the voltage a winding may carry is proportional to frequency to a fitted exponent of 1.000000.
The flux that walks
The previous essay's saturation limit is an amplitude, and an amplitude can be respected. This one cannot. A drive whose two half-cycles differ in volt-seconds by one per cent adds the same small area to the flux every cycle, so it reaches saturation after 64 cycles — and halving the drive gives 128, and a tenth of it gives 637. Reducing the amplitude buys time in exact proportion and removes nothing. There is no amplitude at which the design is inside a limit.
The delay that is two delays
Modelling one comparator delay applied to both transitions makes the two half cycles equal by construction, and the fix is a change of one line. Made, the duty cycle moves by 0.28 per cent for twenty nanoseconds of skew rather than the 0.40 the obvious expression gives, more hysteresis improves the duty cycle and worsens the volt-seconds at the same time, and ten nanoseconds of skew saturates a hundred-turn core in 231 cycles.
The duty cycle that costs nothing
A converter drives its core with a rectangular voltage, so the flux is a triangle whose two slopes differ by nineteen to one at a five per cent duty. The play-operator core charges exactly the same for all of them — 2.1006 joules per cubic metre at every duty and for a sinusoid of the same peak, to three parts in ten thousand — because a rate-independent locus depends on where the flux went and not on how fast. Real cores charge tens of per cent more, and the standard correction hides its entire waveform dependence in α − 1, which is the one term a rate-independent model has none of.
Named alongside it
The objects these essays reach for when they reach for this one.
Volt-secondsModel rangeSaturationDuty cycleMagnetic pathB h loopHysteresisLimit cycleMagnetic lossMarchingPropagation delaySteinmetz equation