Flux density — where it appears
Named by 6 essays across 3 fields — each of them below, with the objects they name alongside it.
A boundary in volt-seconds
A core saturates on the integral of the voltage applied to it, not on the current through it and not at a frequency. The quantity that belongs to the core is N·Ae·Bsat — 3.500 mWb-turn here — and it has no frequency in it at all. Everything a data sheet says about a transformer's frequency rating is that one number divided by 2πf once: measured on a marched flux, the voltage a winding may carry is proportional to frequency to a fitted exponent of 1.000000.
The flux that walks
The previous essay's saturation limit is an amplitude, and an amplitude can be respected. This one cannot. A drive whose two half-cycles differ in volt-seconds by one per cent adds the same small area to the flux every cycle, so it reaches saturation after 64 cycles — and halving the drive gives 128, and a tenth of it gives 637. Reducing the amplitude buys time in exact proportion and removes nothing. There is no amplitude at which the design is inside a limit.
The delay that is two delays
Modelling one comparator delay applied to both transitions makes the two half cycles equal by construction, and the fix is a change of one line. Made, the duty cycle moves by 0.28 per cent for twenty nanoseconds of skew rather than the 0.40 the obvious expression gives, more hysteresis improves the duty cycle and worsens the volt-seconds at the same time, and ten nanoseconds of skew saturates a hundred-turn core in 231 cycles.
The duty cycle that costs nothing
A converter drives its core with a rectangular voltage, so the flux is a triangle whose two slopes differ by nineteen to one at a five per cent duty. The play-operator core charges exactly the same for all of them — 2.1006 joules per cubic metre at every duty and for a sinusoid of the same peak, to three parts in ten thousand — because a rate-independent locus depends on where the flux went and not on how fast. Real cores charge tens of per cent more, and the standard correction hides its entire waveform dependence in α − 1, which is the one term a rate-independent model has none of.
The instant a transformer is worst at
A capacitor-input rectifier draws its worst inrush when it is switched on at the peak of the mains. A transformer's own magnetising branch is the other way round: switched on at the voltage zero, a 230 V primary worked at 1.4 T draws 87.6 A in its first half-cycle, 791 times its settled magnetising current, and at the voltage peak it draws nothing extra at all. The core's flux has to start from zero, the voltage does not, and how close the working flux sits to half of saturation decides the size.
The flux the reset leaves behind
A transformer driven one way only — a forward converter, a single-ended pulse transformer — is reset each cycle by letting its magnetising current fall to zero, and zero current is not zero flux. Marched on the hysteretic core, a power ferrite with 90.6 mT of remanence driven to 0.3 T starts every pulse but the first at 90.8 mT, and keeps 34.9% of the swing a symmetric drive would get, where half is the most a one-way drive could; a square-loop core starts at 212 mT and keeps 14.7%. A gap shears the loop: the current is zero where H = −lg·B/(μ₀·le), so the start is bounded by μ₀·Hc·le/lg and falls onto the bound as the gap grows — 22.0 mT at 0.1 mm, recovering 69 mT of swing for 239 mA more magnetising current. The first pulse from a demagnetised core is the only one that starts at zero, and it is the one a bench test sees.
Named alongside it
The objects these essays reach for when they reach for this one.
Model rangeSaturationVolt-secondsMagnetic pathDuty cycleMagnetising inductanceMarchingSwitching converterB h loopCoreFlux linkageHysteresis